1~10 item / All 10 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~10 item / All 10 items
Our company designs and manufactures "small Stirling engines" that can be combined with simple small combustion devices, including rocket stoves. We can also design and manufacture dedicated rocket stoves, biomass burners, and mobile stands with casters. 【Delivery Example】 <EM15> Rated shaft output: 150W Rated speed: 900rpm Operating gas pressure: N2 or Air below 0.7MPa Starting method: Manual Equipped with an AC PM generator for small wind turbines *For more details, please refer to the materials. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document introduces normal ventilation and external air conditioning ventilation. There are different types of mechanical ventilation, and most buildings in Japan adopt what is called "Type 3 ventilation." Details about "Type 2 ventilation" using external air conditioning units are also provided with diagrams. Please feel free to download and take a look. [Contents] ■ Differences in ventilation methods ■ External air conditioning ventilation ■ Proposal for retrofitting external air conditioning units ■ Air conditioning and virus countermeasures *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Air Pressure Shock Wave Suit Blast" is a device that can remove ash and soot adhered to heat exchangers and other surfaces using shock waves. It can be used while in a high-temperature state (during operation) and also supports timer settings for the interval of shock wave emissions. The shock waves do not damage anything outside their effective range, and they produce minimal noise when leaking outside the furnace. 【Features】 ■ The interval for shock wave emissions can be set from 10 to 100 minutes ■ Uses an air source of 0.7 MPaG or higher *For more details, please refer to the materials. Feel free to contact us with any inquiries.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe Stirling engine is a type of external combustion engine. (Gasoline engines, gas turbines, etc. are internal combustion engines.) It moves the piston by heating and cooling the gas inside the engine from the outside, causing it to expand and contract. Unlike other external combustion engines such as steam engines and steam turbines, it does not lose efficiency when miniaturized, making it suitable for small-scale distributed power generation. 【Features】 ■ A type of external combustion engine ■ Does not lose efficiency when miniaturized ■ Suitable for small-scale distributed power generation *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDuring the emergency of the Great East Japan Earthquake, the experimental Stirling engine generator owned by Ichinoseki National College of Technology generated electricity using waste materials, attracting attention as a small independent power source for disaster prevention. On November 5, 2014, the Electricity Business Act was amended, relaxing regulations on Stirling engine power generation under 10 kW. Stirling engine generators under 10 kW were certified as general electrical equipment that does not require a construction plan notification or the appointment of a chief engineer for boilers and turbines. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIntroducing the "Biomass and Stirling Engine Generator with Incinerator." The biomass fuel fed into the rotary kiln is dried internally before being sent to the incinerator. In the incinerator, the biomass fuel burns, raising the internal temperature to over 800 degrees. The heat generated is sent to the Stirling engine generator through a heat exchanger and converted into electricity. The air that passes through the heat exchanger is transformed into hot air or hot water, which can be utilized in various industrial applications. [Features] - The biomass fuel fed in is dried internally before being sent to the incinerator. - In the incinerator, the biomass fuel burns, raising the internal temperature to over 800 degrees. - The air that passes through the heat exchanger is converted into hot air or hot water. - Can be utilized in various forms for industrial applications. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIn large-scale biomass power plants, biomass resources such as wood are directly burned to generate electricity using steam turbines or steam engines. Large power plants with a capacity of over 5000 kW require a significant amount of wood (around 100 tons per day), leading to competition for resources with regular wood users, and the fact that transportation costs account for more than half of the raw material costs has become a social issue. To address the problems of large-scale biomass power plants, the necessity of decentralized small-scale biomass power plants has been advocated for some time. However, the lack of good small external combustion engines has hindered their spread. One of the solutions that has garnered attention is the Stirling engine generator. *For more details, please refer to the PDF materials or feel free to contact us.*
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "ADMIX-10" is a coaxial Y-type 7.5 kW Stirling engine generator with a horizontally opposed piston 4-cylinder reed valve circulation flow system. It has a total length of 1807 mm, a width of 1058 mm, a height of 1009 mm, and weighs 450 kg, and is designed for selling electricity under the renewable energy fixed price purchase system. We provide power and heat tailored to your needs, from power generation operators to horticultural farmers and independent power sources for disaster prevention. [Features] - 7.5 kW Stirling engine generator - Total length of 1807 mm, width of 1058 mm, height of 1009 mm, weight of 450 kg - Designed for selling electricity under the renewable energy fixed price purchase system - Dedicated rotary kiln, incinerator, hot air and hot water equipment available as optional sales - We supply power and heat tailored to your needs, from power generation operators to horticultural farmers and independent power sources for disaster prevention *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "ADMIX-07" is a horizontally opposed piston 4-cylinder reed valve circulation type α 500w Stirling engine generator. With a total length of 870mm, a width of 479mm, a height of 509mm, and a weight of 45kg, it can generate electricity even from small heat sources such as fireplaces or barbecue grills. (Heat exchanger 30cm x 30cm) Even in outdoor situations where gasoline or gas is hard to obtain, it can generate electricity as long as there is something to burn. In emergencies, it can also be used as a portable small-scale independent power supply for disaster prevention. 【Features】 ■ 500w Stirling engine generator ■ Total length 870mm, width 479mm, height 509mm, weight 45kg ■ Can generate electricity from small heat sources such as fireplaces or barbecue grills ■ Can generate electricity even in outdoor situations where gasoline or gas is hard to obtain, as long as there is something to burn ■ Can be used as a portable small-scale independent power supply for disaster prevention in emergencies *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Stirling engine" is a type of external combustion engine. It moves the piston by heating and cooling the gas inside the engine from the outside, causing it to expand and contract. Unlike other external combustion engines such as steam engines and steam turbines, it does not lose efficiency when miniaturized, making it suitable for small-scale distributed power generation. ADMIEXCO Engine Design Co., Ltd. aims to contribute to energy issues by developing a new energy market utilizing unused resources through the practical application of small Stirling engine generators. 【Overview of Biomass Stirling Engine Generator with Incinerator】 - Biomass fuel fed into the rotary kiln is dried internally before being sent to the incinerator. - In the incinerator, the biomass fuel burns, raising the internal temperature to over 800 degrees. - The generated heat is sent to the Stirling engine generator through a heat exchanger and converted into electricity. - The air that passes through the heat exchanger is transformed into hot air or hot water, allowing for various industrial uses. For more details, please contact us or download the catalog.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration