1~6 item / All 6 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us OnlineBefore making an inquiry
Download PDF1~6 item / All 6 items
The "RED GATE newsletter Summer 2016" is a publication by Akamon Wirex Co., Ltd., which is engaged in cleaning, disinfecting, and maintenance management of air conditioning equipment and various ducts. It features a "REPORT" introducing the causes and countermeasures for heatstroke, as well as sections such as "COLUMN" and "NEWS." [Contents] ■REPORT "Be Careful of Heatstroke" ■COLUMN "Living Jewels! The Insect Tamamushi Used in National Treasures" ■NEWS "Exhibition Participation Announcement" For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "RED GATE newsletter Spring 2016" is a publication by Akamon Wilex Co., Ltd., which conducts cleaning, disinfection, and maintenance management of air conditioning equipment and various ducts. It features a "REPORT" introducing the story of mold, which is essential for sake brewing, as well as "COLUMN" and "NEWS." [Contents] ■REPORT "The Story of Mold" ■COLUMN "Wait!? The Smell of Stink Bugs is Pleasant!?" ■NEWS "Exhibition Participation Announcement" For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"CoLoC" is an all-stainless steel adhesive roll holder without any plated parts. We solve problems such as "lost parts," "broken parts," and "hard to reach." 【Features】 - Total length: 370mm, width: 170mm, weight: approximately 113g - Simple structure and durable - No worries about losing parts due to its integrated design - Utility model No. 3171809 For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "IAQ (Indoor Air Quality) method" uses a powerful dust collector and compressor to reverse wash the air conditioning ducts and remove internal dust. An air whip is inserted through IAQ ports installed at regular intervals in the duct, and compressed air from the compressor is sent into the thin tube of the air whip, causing its tip to dance vigorously and strike the inside of the duct forcefully. This operation forcibly disperses the dust accumulated inside the duct, which is then suctioned and collected by the powerful dust collector attached to the duct trunk. 【Features of the Method】 ■ Uses the power of the air whip and compressed air to knock out dirt ■ Quickly addresses long ducts that are difficult to access ■ Captures dirt with a powerful dust collector ■ Easy inspection and cleaning with IAQ ports For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt Akamon Willex Co., Ltd., we have conducted numerous kitchen exhaust duct cleanings from the perspective of fire prevention. Investigations have revealed that many fires are caused by uncleaned exhaust ducts, where grease and dust accumulate on the duct surfaces, leading to the spread of flames. Our cleaning services not only cover the ducts but also remove grease and dust from hoods, filters, fire dampers, and exhaust fans. If fire dampers are not cleaned, they may fail to operate or take too long to function during a fire, preventing effective flame suppression. Therefore, we recommend regular inspections and thorough cleaning of all equipment as fire prevention and disaster mitigation measures. 【Kitchen Exhaust Duct Contamination Diagnosis Methods】 ■ Endoscopic Diagnosis Method - A simple method that allows for quick completion of the work. ■ Grease Thickness Measurement Diagnosis Method - This method uses a thickness gauge to measure the thickness of grease and dust on the inner surfaces of kitchen ducts and equipment, allowing for confirmation of contamination levels and evaluation of cleaning effectiveness. For more details, please refer to our catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAkamon Wilex Co., Ltd. is a company that focuses on creating high-quality environments in various buildings, including office buildings, hospitals, food factories, and manufacturing plants. They carry out services such as air duct cleaning (IAQ method), drainage pipe cleaning, and asbestos removal. They conduct interviews with facility personnel and perform various inspections. Based on the results, they develop a sanitation management schedule and implement sanitation management practices. Regular diagnostics and analytical evaluations are conducted. By clearing the set goals, they achieve a higher level of sanitation management and offer a wide range of services tailored to meet needs. 【Business Activities】 ■ Comprehensive sanitation management for food factories ■ Exhaust duct cleaning ■ Pest and vermin control ■ IAQ systems ■ Internal inspections using inspection cameras ■ Drainage pipe cleaning ■ Asbestos dispersion prevention treatment ■ Environmental microbial control systems for medical facilities ■ Investigation, analysis, and inspection *For more details, please refer to the catalog or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration