Termination boards provide direct connection via dedicated multicore cable between the I/O Card of the system (PLC/DCS/ESD) and electronic modules (barriers, isolators, relays). GM International offers a wide range of standard or customized termination boards to easily interface to systems of all the main instrumentation vendors such as: Invensys Foxboro, ABB, Triconex, Yokogawa, Honeywell and many others. GM International termination boards are also available with the new HART Interface System that drastically reduces the number of multiplexer modules 【Features】 Smaller foot print: very compact design, up to 64 I/O channels in one board ■Sturdy metal: mounting hardware for DIN-rail or wall ■High availability: power supply and support of I/O redundancy ■Easy maintenance and troubleshooting: fault led Indication and common fault repeater ■Available with customized connectors/cables for direct interface to any PLC / DCS / ESD Systems ■Also available with GMI HART interface system that drastically reduces the number of multiplexer modules. ■AI/AO/DI/DO universal: any D5000 or D6000 series modules can be installed: IS barriers, isolators, safety relays *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The new SIL 3 certified GM International HART interface system drastically reduces the complexity and cost of HMS installations; compared to the current state-of-theart HART interface solutions on the market, GMI HART System significantly cuts the number of multiplexer modules required and increases the speed of communication to 115.200 bps 【Features】 ■ Reduced foot print: high density, 256 channel ■ Increased architecture ability: 63 configurable addresses ■ Faster data acquisition: 115.200 Baud speed ■ Reduced wiring: slaves are not required ■ High Reliability, critical environments: certified -40° to +70° C ■ Higher resiliance: channel to channel isolation ■ Data guaranteed by 3rd party: SIL 3 TÜV certification ■ Current & valid standard: certified IEC 61508:2010, Ed.2 ■ Lower ownership cost: certified for 20 years operation *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "D9000 Series" is a SIL3 lightning arrester (arrester) designed for use in all applications including oil and gas, petrochemicals, steel, and more, with explosion-proof specifications. It features built-in knife switches for each channel and can be installed in Zone 1 and Zone 2 hazardous locations, accommodating signal inputs from Zone 0 (Zone 20). Versions with built-in fault indication and hot-swappable modules are also available. 【Features】 ■Easy maintenance: integrated knife disconnection technology for each channel ■Quick wiring: grounding path via contact to DIN-rail ■Reduced spare inventory: surge protection for most I/O signals; AI, AO, DI, DO. Nominal 24V DC, maximum 30V(Both I.S. And N.I.S.) ■Increase the discharge capacity and reduce the response time: 2-stage protective circuit (diode, gas-discharge tube) ■Unlimited IS applications: input from zone 0 (zone 20),installation in zone 1 and 2 ■Fits in any SIL loop: SIL3 certification ■Protection level: up to 20 KA ■Simple testing and documentation, reduced downtime:Hot swap plug module (I.E. D9510S, D9520S) ■Safe disconnection and signaling in case of overload *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "D2000 Series" is a multiplexer system specially designed for temperature measurement in hazardous locations. It was developed with the aim of making full use of low power for temperature measurement. The field units installed in hazardous locations do not require explosion-proof certified power supplies. The same system can process both analog (temperature signals) and digital input signals, or a combination of both. Users can build a suitable system for their purposes, achieving significant cost reductions such as in cable installation expenses. 【Features】 ■Reduced foot print: high density, up to 256 channel ■Longer distances: up to 4/5 Km between sensor gateway. ■Higher reliability: certified -40° to + 60° C ■Avoid fault propagation: channel to channel isolation ■Resilience to surges: 500 V isolation ■Faster reaction time: from 0,4 sec for 64 Ch. to 1.6 sec for 256 Ch. ■Faster data collection: 112 KBaud communication speed ■Harsh environment resistance: G3 conformal coating ■Easier troubleshooting: status LED indication *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The "PSx1200 series" is an explosion-proof power supply unit designed to guarantee an output voltage of 20-30Vdc under both normal and fault conditions. It is certified with SIL3 functional safety level, and the 24Vdc redundant power supply can be installed and used in safe and Zone 2 (Class II hazardous locations) areas. Additionally, it incorporates Ideal OR-ing diode technology and load sharing circuits. 【Features】 ■Smaller foot print: very compact design ■Flexibility: wall/rack/DIN-rail types ■Environmental condition: extended temperature range (-40°C ~ +70°C), G3 coating, tested for marine application(EMC, vibration, etc.) ■Zone 2 installation: reduced cable distance ■Improved safety, integrity and reliability: SIL 3 certified by third party ■High efficiency - reduced bulk power & dissipation: builtin intelligent load sharing ■Easier Installation: no external OR-ing diodes needed for redundancy ■Zero Downtime: built-in redundancy, operation under output short-circuit condition, automatic load sharing of 2 or more modules ■Reduced maintenance cost: hot swapping, also in zone 2 (PSS1250) ■Guaranteed fault isolation: short circuit protection ■Easier troubleshooting: local and remote (optional Modbus) diagnostic *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The D6000 series is a galvanic isolators that supports applications in all industrial fields. GM International SIL 2 certified isolators are suitable for applications in all industrial sectors and designed to achieve the highest possible reliability and availability through the use of high temperature class components and low dissipation circuitry. By avoiding the use of electrolytical capacitors, and with state-of-the-art assembly and testing facilities, 20 years useful life time is achieved. It is suitable for applications that require SIL3 functional safety levels compliant with IEC61508 and IEC61511. 【Features】 ■ SIL 3: TÜV certification; according IEC 61508:2010, Ed.2 ■Reduced foot print: high density: 1, 2, 4 or 8 ch.s each ■Simplified installation/config.: DIP switch configurability ■Faster reaction time; lower down time: LED indication for power, signal status and line fault ■Lower ownership cost: certified for 20 years operation ■Reduced spare inventory: universal mounting (stand alone DIN-rail, power bus system and termination boards) ■Improved reliability: low power consumption and heat dissipation ■Higher reliability in & outdoor: certified -40° to + 70° C ■RS-485 Modbus output version available *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
Any time a relay is required and must be used in a SIF, it must conform and adhere to IEC 61508 and to the relevant industry standard (i.e. 61511). Typical cases : • Controller cannot meet power requirement (V or A) • Multiplication of contacts is required • Controller Safety Function must be inverted SIL certified relays are not used exclusively in Oil & Gas or petrochemical industries; they are also a must in many other industries: • Railways • Cars and lift • Power distribution • Any time a failure of the relay can cause a serious accident [Features] • Reduced foot print: high density, 12,5/22,5 mm per ch. • Full 3rd party certification: Coil-to-Contact SIL2/3 TÜV certified • True reliability: compatible to DO Card LM pulses • Reduced space/eng. Costs: smart line/load monitoring with transparent fault indication (no additional contacts) • Lower ownership/maintenance cost: T-proof times: 10/20 years • Reduced spare inventory: universal mounting: DIN-rail and Termination Boards • Higher reliability in & outdoor: certified -40° to + 70° c • Totally independent dual ch.: dual circuits • Full application coverage: modules available with 5 & 10 Amps contact, NE/ND application • Harsh environment resistance: G3 conformal coating • Reliable switching operations: gold-plated relay contacts *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
The GM International D1000 series IS barrier is yet unsurpassed in reliability and performance, providing the simplest and cost effective range of technology to implement intrinsic safety into hazardous areas and divisions. The complete line of D1000 series IS barriers is suitable for SIL 3 - SIL 2 applications according to IEC 61508, IEC 61511. 【Features】 • Reduced Foot Print: High density, 4 Channels • Full Application Coverage: All INs and OUTs available • Reduced Spare Inventory: Available as universal IN/OUT • Reliable Indoor & Outdoor: Certified -40° to + 60° C • Resilience to Surge: 1.5 KV isolation • SIL 3 (2) TÜV certification: Data guaranteed by 3rd Party • Easy Installation: Din Rail & Power Bus mounting • Easy Maintenance: Plug-in Enclosure • Current & Valid Standard: Certified IEC 61508:2010, Ed.2 • Independent SIL certified Dual Ch.: Dual Power Supply *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration
GM International D5000 series uses state-of-the-art solutions to achieve the highest performance for Intrinsically Safe applications; guaranteed by over 15 certification bodies all over the world. Intrinsically Safe Galvanic Isolators provide the most simple and cost effective means of implementing Intrinsic Safety into Hazardous Area applications. 【Features】 ■ No Type A grounding required ■Reduced foot print: high density, 6 mm per channel ■Reduced bulk power supply: low power consumption ■Reduced cooling needs: low heat dissipation ■Higher reliability in & outdoor: certified -40° to + 70° c ■Higher resilience to surges: 2.5 Kv isolation ■Data guaranteed by 3rd party: SIL 3 (2) TÜV certification ■Current & valid standard: certified IEC 61508:2010, Ed.2 ■Harsh environment resistance: G3 conformal coating ■Lower ownership cost: certified for 20 years operation ■Reduced spare inventory: universal mounting (stand alone DIN-rail, power bus system and termination boards) ■Independent SIL certified dual ch.: dual power supply *For more details, please download the PDF or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration