The "ECL-88AO Lite" is an integrated Nox and O2 monitor that has achieved thorough lightweight design for field measurements. It features a "depressurized NOx meter" that employs a highly reliable bypass flow-chopping gas analyzer, combined with a "magnetic force O2 analyzer" using flow-chopping gas analysis method, allowing for high-precision continuous measurement of nitrogen oxides and oxygen in flue gas. Additionally, we offer a wide range of options and specifications to meet various user needs according to the measurements. 【Features】 ■ Built-in pre-treatment device weighing 19kg ■ Achieves lightweight and space-saving design ■ Improved maintenance and operability ■ Simple key operation ■ Minimal running costs *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "TN-310" is a device capable of measuring total nitrogen in accordance with the "Contact Thermal Decomposition and Chemiluminescence Method" adopted by JIS K0102. Compared to measurements using methods such as spectrophotometry, it significantly reduces measurement time, making it widely applicable for nitrogen treatment control of various wastewater and for effluent monitoring. Additionally, when measuring samples that include seawater, using ultraviolet spectrophotometry can lead to positive interference from odor substances; however, this product is unaffected by such interference due to its different detection method, resulting in high consistency with the specified measurement method (summation method). 【Features】 ■ Compliant with the Contact Thermal Decomposition and Chemiluminescence Method ■ Capable of measuring total nitrogen in a wide variety of samples ■ Provides high precision and reproducibility in measurements ■ Supports multi-series measurements ■ Employs a negative pressure suction method for sample collection *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe TPN-580 is a fully automated total phosphorus and total nitrogen measurement device that achieves high consistency with manual analysis under equivalent conditions to the specified measurement method. While inheriting the maintenance and measurement performance of conventional models, it has been upgraded to a device that further satisfies customers by incorporating a large LCD touch panel and individual measurement functions for total phosphorus and total nitrogen. Additionally, it is equipped with comprehensive features and a rich display. 【Features】 ■ High accuracy and stability ■ Measurement compliant with the specified measurement method through heating at 120°C for 30 minutes ■ Equipped with a uniquely developed autoclave chamber that excels in heat resistance, pressure resistance, and chemical resistance ■ Unique detection system that enables long-term stable measurements ■ Uses a negative pressure suction method for sample collection *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "TCN-580" is an automatic measuring device capable of high-precision continuous measurement of total cyanide. Thanks to its unique technology (negative pressure ventilation distillation - cyanide ion electrode measurement method), it can recover free cyanide and complexed cyanide in samples in as little as 30 minutes, and by using ventilation distillation for concentration, reliable measurement values can be obtained from low concentrations (0.01 mg/L). Additionally, it is possible to confirm the cyanide recovery curve during normal measurements or automatic calibration. 【Features】 ■ High accuracy and stability ■ Total cyanide measurement possible from 0.01 mg/L with the shortest measurement cycle of 30 minutes ■ High selectivity measurements even in the presence of interfering substances ■ Real-time confirmation of recovery curves ■ Self-diagnosis function reduces maintenance management tasks *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe EHF-770V is a heated VOC monitor that utilizes Yanako's proven HOT-FID (heated FID with all measurement lines heated) technology to accurately and comprehensively measure the concentration of VOC (volatile organic compounds) gases emitted into the atmosphere. It is suitable for bag measurements of VOC gases as specified by the Ministry of the Environment and for continuous measurements as part of self-management. Additionally, by heating the sample gas inlet to the detector outlet, it minimizes the impact of adsorption of high-concentration and high-boiling point gases, enabling high-precision and rapid continuous measurements of VOC gases generated in various production processes. 【Features】 ■ Capable of long-term continuous measurement ■ Suitable for continuous monitoring ■ Capable of continuous measurement of organic chlorine gases ■ Suitable for screening of work environment measurements ■ Compatible with various continuous measurement applications *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "FLO-180" is an automatic measuring device using the all-ion strength adjustment buffer solution conditions - fluoride ion electrode measurement method. It enables measurements with a minimum cycle of about 15 minutes across a wide range from low to high concentrations. It can accommodate various applications, from continuous monitoring to process water control. Additionally, if there are many interfering components for the ion electrode, they can be avoided with a dilution mechanism. The amount added may be adjusted depending on the pH. 【Features】 ■ Capable of supporting process control and discharge monitoring ■ Employs a negative pressure suction method for sample collection ■ Can meet needs from low to high concentrations ■ Supports optimization according to sample composition ■ Offers various options to accommodate a wide range of needs *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "PNL-780D" is a measurement device that automates the phenol measurement method using the "4-Aminoantipyrine spectrophotometric method" according to JIS standards. It allows measurements from 0.1 mg/L in a short time and can be widely used for applications such as process management and labor-saving measurements as an alternative to manual analysis. Additionally, the light source lamp uses long-life LEDs, reducing maintenance for customers. 【Features】 ■ Adopts the 4-Aminoantipyrine spectrophotometric method according to official standards ■ Unique detection system enabling long-term stable measurements ■ Uses negative pressure suction method for sample collection ■ Allows measurements from 0.1 mg/L in a short time ■ Can be widely used for applications such as labor-saving measurements as an alternative to process management and manual analysis *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "NH-180" is an automatic ammonia measurement device based on the ion electrode method (alkaline conditions - ammonia electrode method) as per JIS K 0102. It allows for accurate and rapid measurements from low to high concentrations, making it suitable for continuous monitoring and controlling chemical injection in various wastewater treatment processes. Additionally, it offers a variety of options tailored to customer needs, achieving stable long-term continuous measurements through the integration of unique technologies. 【Features】 ■ Utilizes a negative pressure suction method for sample collection ■ Capable of meeting needs from low to high concentrations ■ Optimized according to sample composition ■ Various options available based on customer needs ■ Achieves stable long-term continuous measurements through the integration of unique technologies *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "TOC-380R" is an automatic TOC measuring device capable of measuring a wide range from low to high concentrations with a minimum cycle time of 6 minutes. Due to its correlation with COD values based on specified measurement methods, it is suitable for measuring various samples, from continuous monitoring applications to process water management. Additionally, to meet a wide range of user needs, it offers various options and achieves high-precision long-term continuous measurements through the integration of unique technologies. 【Features】 ■ Uses a negative pressure suction method for sample collection ■ Unique detection system enables long-term stable measurements ■ Self-diagnosis function reduces maintenance workload ■ Capable of measuring a wide range from low to high concentrations with a minimum cycle time of 6 minutes ■ Suitable for measuring various samples, from continuous monitoring applications to process water management *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe COD-380 is an automatic COD measurement device that fully automates the conditions equivalent to the Japanese Industrial Standard JIS K 0102 (Factory Wastewater Testing Method) and achieves a high correlation with the same testing method. It detects the endpoint using a constant current polarization potential difference method with a dual platinum electrode that can detect redox reactions differentially, ensuring accurate endpoint detection that is not influenced by the characteristics of the sample. Additionally, it allows for measurement scheduling based on time and day. Multi-channel measurements can also be executed according to the scheduled settings. 【Features】 ■ High accuracy and stability ■ The heating method for COD measurement adopts a boiling water circulation system ■ Utilizes a unique endpoint detection method ■ Employs a negative pressure suction method for sample collection ■ Comprehensive functions and rich display options *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration