The "VMB-08W" is a high-performance, single-channel intermittent continuous underwater VOC monitoring device suitable for field measurements. It incorporates one underwater VOC monitor within a control panel, automatically sampling factory wastewater intermittently. After sampling, it vaporizes the dissolved VOCs in water through heating and aeration, allowing for VOC concentration monitoring. Inside the control panel (outdoor standalone type, SUS specification), in addition to the VOC monitor itself, it contains a heating and vaporization unit, cooling pipes, an electronic cooling dehumidifier with an auto-drain device, a quantitative liquid delivery pump, and a chilled water circulation system. Additionally, we also handle the underwater VOC measurement monitor "VM-850R-Z." 【Features】 ■ High functionality ■ Suitable for field measurements ■ One underwater VOC monitor built into a single control panel ■ Vaporizes dissolved VOCs in water to monitor VOC concentration *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document is an overview of the residual solvent (VOC) simple testing device 'RVA-03' handled by OSP. It introduces the necessity of simple measurement of residual solvents, the headspace GC method, measurement methods and operational overview, as well as the differences and advantages compared to GC methods. The "RVA series" is a device that allows for simple testing of the amount of residual organic solvents (total VOC) in printed sheets and adhesive films. [Contents] ■ Introduction ■ Conventional Method: Headspace GC Method ■ Overview of the Residual Solvent Simple Testing Device (RVA-03) ■ Applications and Measurement Examples: Correlation with GC Methods, etc. ■ Differences and Advantages Compared to GC Methods ■ Others: Detection Principle (IER Method VOC Sensor) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document presents the results of the verification tests for the simple VOC monitor 'VM-603' handled by OSP. It includes an overview of the verified technology, as well as details about the verification tests, results, discussions, and reference information. The "VM-600 series" is an intermittent continuous monitoring device that samples the target gas to measure VOCs, making it suitable for work environment measurements and leak alarms. [Contents] ■ Verified technology ■ Overview of the verified technology ■ Overview of the verification tests ■ Results and discussions of the verification tests ■ Reference information *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "VM-500 Series" is an intermittent continuous monitoring device that samples the target gas to measure VOCs. It is equipped with an automatic control function for zero-point calibration air, enabling reproducible long-term monitoring measurements. Additionally, we also offer the wall-mounted simple VOC monitor "VM-604," which inherits the basic performance of the handheld VOC sensor. 【Features】 ■ Wide detection range / with analog output / with two-stage alarm contacts ■ Capable of intermittent continuous operation / maximum memory of 1,000 points ■ Automatic control function for zero-point calibration air ■ Capable of reproducible long-term monitoring measurements ■ ETV verified model (VM-501) *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration◆Product Features◆ - A handy type measuring device that can easily and quickly detect the total concentration of volatile organic compounds (VOCs) such as petroleum-based and chlorine-based substances on-site. - With a built-in pump, it allows for direct suction measurements from exhaust gases in ducts, surface gas measurements, and from boreholes (up to 10m deep), making it ideal for simple checks and preliminary screenings. - The headspace measurement method enables highly sensitive detection of VOC components in water. - No specialized knowledge is required; anyone can easily perform measurements. - Measurements can be completed in 1 to 2 minutes (results are immediately available on-site). - Low cost. - High correlation with GC methods → High reliability. Wide detection range (switchable between 2 ranges) with toluene equivalent values from ppm to several thousand ppm. - Measurement values can be stored in memory for up to 1000 points (can communicate with a computer via dedicated software and USB connection). - Automatic monitoring function (when using the optional monitoring measurement kit). ◆For more details, please request materials or download the catalog◆