1~19 item / All 19 items
Displayed results
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationContact this company
Contact Us Online1~19 item / All 19 items
The "OXYMAN Series" is a high-performance oxygen monitor that can stably measure oxygen concentrations from 0 to 100% over a long period, thanks to the adoption of a wide-range, long-life galvanic battery-type oxygen sensor. It can be used both as a portable device and for wall mounting. It can be widely used for safety checks in oxygen-deficient hazardous areas, as well as for long-term monitoring and management of oxygen concentrations. 【Features】 ■ Measures oxygen concentration from 0 to 100% O2 ■ Simple mode for preventing oxygen deficiency accidents ■ Long sensor life (expected lifespan: approximately 3 years in the atmosphere) ■ Data output to a computer via RS-232C communication ■ External alarm output (relay contact output for alarms) *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis product is a data collection software for the "OXYMAN series," which is an oxygen monitor. By communicating with the same series, it allows for the graphical display and file saving of oxygen concentration. It can perform continuous sampling for an extended period (up to one week). Additionally, it can be converted into an Excel file. For more product details, please contact us. 【Features】 ■ Manage oxygen concentration data on a computer ■ Graphical display and file saving of oxygen concentration ■ Capable of long-term (up to one week) continuous sampling *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "OXYMAN Plus" is a high-performance oxygen monitor that allows you to switch between two modes: "Simple Mode" and "Multi Mode." You can set the HIGH/LOW alarm threshold to any oxygen concentration, and with the built-in memory function, it can log up to 1500 data points. We offer sets with rotating lights for all models. 【Features】 "Simple Mode" ■ Oxygen deficiency monitoring (alarm activation and deactivation (manual) for oxygen concentration below 18%) ■ PC communication (real-time data communication) "Multi Mode" ■ HIGH/LOW alarm (automatic alarm activation and deactivation based on user-defined oxygen concentration) ■ Data logging (with reservation function, up to 2 channels × 1500 data points) ■ PC communication (real-time data and logging data communication) ■ Calibration with standard gas (user-defined standard gas with oxygen concentration of 10-100%) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"OXYMAN" is an oxygen monitor that limits the number of operation buttons to three, making it easy for anyone to use. By adopting a wide-range, long-life galvanic battery-type oxygen sensor, it is capable of measuring oxygen concentrations from 0 to 100% stably over a long period. With graph display software, visual concentration monitoring can be done on a computer, and the data can be retained as evidence. It can be used either as a portable device or mounted on a wall, and it offers two types: the "MS Type," which is specialized for oxygen deficiency alarms, and the "MF Type," which allows switching between an oxygen deficiency alarm mode (simple mode) and a free oxygen concentration measurement mode (free mode). A set with a rotating light is available, and user alarm signal contacts can also be accommodated. 【Features】 "Simple Mode" "Free Mode" ■ Long sensor lifespan (expected lifespan: approximately 3 years in the atmosphere) ■ PC communication (real-time data transmission) "Simple Mode" ■ Oxygen deficiency monitoring (alarm activation and deactivation (manual) when oxygen concentration falls below 18%) ■ Relay contact output for alarms is possible *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "OXYMAN Plus" is a high-function oxygen monitor that allows you to switch between two modes: "Simple Mode" and "Multi Mode." You can set the HIGH/LOW alarm threshold to any oxygen concentration, and with the built-in memory function, it can log up to 1500 data entries. We offer sets with rotating lights for all models. 【Features】 "Simple Mode" ■ Oxygen deficiency monitoring (alarm activation and deactivation (manual) for oxygen concentration below 18%) ■ PC communication (real-time data communication) "Multi Mode" ■ HIGH/LOW alarm (automatic alarm activation and deactivation based on any oxygen concentration value) ■ Data logging (with reservation function, up to 2 channels × 1500 entries) ■ PC communication (real-time data and logging data communication) ■ Calibration with standard gas (user standard gas with oxygen concentration of 10-100%) *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "OXYringe" is an oxygen concentration meter that measures the oxygen concentration of gas by injecting gas collected with a syringe into this device. It has achieved a low price by focusing on syringe sampling and basic performance for measuring residual oxygen concentration in food packaging undergoing gas replacement. Additionally, its usefulness has been confirmed for precision electronic devices that have also undergone gas replacement. 【Features】 ■ Capable of measuring small samples of 5ml ■ Equipped with memory function (POM-2501M) ■ Equipped with memory function and RS-232C communication function (POM-2501C) ■ No influence from carbon dioxide *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration"OXYMAN" is an oxygen monitor that limits the number of buttons for operation to three, making it easy for anyone to use. By adopting a wide-range, long-life galvanic battery-type oxygen sensor, it is capable of measuring oxygen concentrations from 0 to 100% stably over a long period. With graph display software, visual concentration monitoring can be done on a computer, and the data can be saved as evidence. It can be used both as a portable device and wall-mounted, and it offers two types: the "MS Type," which is specialized for oxygen deficiency alarms, and the "MF Type," which allows switching between oxygen deficiency alarm mode (simple mode) and free oxygen concentration measurement mode (free mode). A set with a rotating light is available, and user alarm signal contacts can also be accommodated. 【Features】 "Simple Mode" "Free Mode" ■ Long sensor life (expected lifespan: approximately 3 years in the atmosphere) ■ RS-232C computer communication (real-time data transmission) "Simple Mode" ■ Oxygen deficiency monitoring (alarm activation and deactivation (manual) when oxygen concentration falls below 18%) ■ Relay contact output for alarms is possible *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Picoammeter iDC Series" is a current meter designed for embedded applications that automatically measures with a wide dynamic range (8 digits) and low noise. By miniaturizing the amplification circuit, A/D conversion circuit, and communication circuit through high integration, it has become easier to connect to the detection unit and shorten input cables, resulting in significant noise reduction. 【Features】 ■ Sends and displays current values with 5 significant digits over a calibrated 8-digit dynamic range to a computer ■ Capable of high-speed measurement and data transmission every 0.01 seconds ■ Compact size facilitates installation near measurement points ■ Measurement cycle can be set for speed priority or noise reduction priority *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "OXYringe" is an oxygen concentration meter that measures the oxygen concentration of gas by injecting gas collected with a syringe into this device. It has achieved a low price by focusing on syringe sampling and basic performance for measuring the residual oxygen concentration in food packaging undergoing gas replacement. Additionally, its usefulness has also been confirmed for precision electronic devices that have undergone gas replacement. 【Features】 ■ Capable of measuring small samples of 5ml ■ Memory function included (optional) ■ No influence from carbon dioxide *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a notice about the low-oxygen atmosphere generation device OXYPASS from Taiyoh Electric Co., Ltd.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can measure with high accuracy in the range of 0 to 100%, making it suitable for a wide variety of applications. It can continuously measure for over 9000 hours (about one year) on batteries. Automatic calibration can be easily performed in clean air. With graph display software, visual concentration monitoring can be done on a computer, and the data can be retained as evidence. In the high-function model, by appropriately setting low and high concentration alarm points and utilizing external outputs, it enables the management of oxygen concentration within a certain range, and data logging (with reservation function) can also be performed. All models come with a set that includes a rotating light. User alarm signal contacts are also available.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt can be measured with high precision in the range of 0 to 100% O2, making it suitable for a wide range of applications. It can continuously measure for over 10,000 hours using only batteries (provided there are no alarms or communications). Automatic calibration can be easily performed in clean air. With the optional data collection software (Windows version, available for free distribution), measurement data can be imported to a computer, and there is also a graph display function. In the high-function model, by appropriately setting the alarm points on the low/high concentration side, a system can be built to maintain oxygen concentration within a certain range. Additionally, there is a series of 2-channel sensors that allow simultaneous measurement at two locations with one main unit (the right side of the photo shows a type that combines one built-in sensor and one separate sensor. There is also a type with two separate sensors). Furthermore, starting from the sales in September 2005, data logging functionality has been equipped, allowing data to be uploaded via computer communication (with a maximum of 1,500 data points, 13 types of sampling intervals from 5 seconds to 60 minutes, and a start time reservation function).
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe atmospheric ion counter is a high-performance ion counter that uses a gel dielectric capacitor in the ion collection section. It draws in air using a pump and measures and displays the number of positive (or negative) ions per cc.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe microcurrent measurement unit is a current meter for equipment integration, consisting of a current measurement module and a control board. In particular, the current measurement module features a compact design the size of a palm. (The input section has a BNC connector.)
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSince there is a correlation between the supply fan inlet temperature, culture medium temperature, and outlet temperature, this relationship formula will be determined during the performance tests of each unit conducted at the factory and stored in the control unit. During cell observation in the laboratory, the culture medium temperature will be calculated and displayed using this relationship formula based on the supply fan inlet temperature and outlet temperature. The control unit will adjust the supply fan inlet temperature to ensure that the displayed temperature matches the observation set temperature. As a result, a temperature setting error of ±1.0℃ or less has been achieved.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThere is a correlation between the supply fan inlet temperature, the culture medium temperature, and the outlet temperature. Therefore, this relationship formula will be determined during the performance tests conducted for each unit in the factory and stored in the control unit. During cell observation in the laboratory, the culture medium temperature will be calculated and displayed using this relationship formula based on the supply fan inlet temperature and the outlet temperature. The control unit will adjust the supply fan inlet temperature to ensure that the displayed temperature matches the observation set temperature. This has achieved a temperature setting error of ±1.0°C or less.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThere is a correlation between the supply fan inlet temperature, culture medium temperature, and outlet temperature of the warm air supply box. Therefore, this relationship equation will be determined during the performance tests conducted for each unit in the factory and stored in the control unit. During cell observation in the laboratory, the culture medium temperature will be calculated and displayed using this relationship equation based on the supply fan inlet temperature and outlet temperature. The control unit will adjust the supply fan inlet temperature to ensure that the displayed temperature matches the observation set temperature. This has achieved a temperature setting error of ±1.0°C or less.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThere is a correlation between the supply fan inlet temperature, culture medium temperature, and outlet temperature of the warm air supply box. Therefore, this relationship formula will be determined during the performance tests conducted for each unit in the factory and stored in the control unit. During cell observation in the laboratory, the culture medium temperature will be calculated and displayed using this relationship formula based on the supply fan inlet temperature and outlet temperature. The control unit will adjust the supply fan inlet temperature to ensure that the displayed temperature matches the observation set temperature. This has achieved a temperature setting error of ±1.0°C or less.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "Picoammeter iDC Series" is a current meter designed for embedded devices that automatically measures with a wide dynamic range (8 digits) and low noise. By miniaturizing the amplification circuit, A/D conversion circuit, and communication circuit through high integration, it has become easier to connect to the detection unit and shorten input cables, resulting in significant noise reduction. 【Features】 ■ Sends and displays current values with 5 significant digits over a calibrated 8-digit dynamic range to a computer ■ Capable of high-speed measurement and data transmission every 0.01 seconds ■ Compact size facilitates installation near measurement points ■ Measurement cycles can prioritize speed or noise reduction *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration