We conducted a thermal transfer analysis of an internal radiation container composed of multiple radiation zones.
**Case Overview** ■Product Name: Femap Thermal ■Analysis: Thermal Analysis ■Industry: Other In this analysis example, we conducted a thermal radiation transfer analysis within a container composed of multiple radiation areas. In this case, the radiation areas consist of three regions: the interior of the container, which includes the heat source, heated surface, and inner wall; the space between the inner and outer walls; and the area from the outer wall to the environment. The calculation of the form factor is known to be time-consuming due to the exhaustive element-to-element calculations, resulting in a large matrix size. Femap Thermal utilizes the Hemicube method with OpenGL to process the time-consuming form factor calculations quickly. Additionally, with a dedicated interface for thermal analysis, it is easy to set up radiation configurations even for models with multiple enclosures. □ For other features and details, please refer to the catalog.
Inquire About This Product
basic information
This is an introduction to a case study of radiative heat transfer analysis within a container using Femap Thermal.
Price information
******
Delivery Time
Applications/Examples of results
For more details, please contact us.
catalog(1)
Download All CatalogsCompany information
At N.S.T, we provide a variety of support to comprehensively assist our customers in better manufacturing, from offering diverse analysis tools and their utilization methods to contract analysis. Our company provides truly usable numerical analysis tools and seamlessly supports the introduction and operation of these tools by leveraging the know-how gained through our extensive experience in the field of numerical analysis.