Simultaneous detection and display of oxygen and hydrogen sulfide.
Sensor separation type with a standard 5m sensor extension cable. Simultaneous detection and display of oxygen and hydrogen sulfide. Measurement concentration is displayed in large digital numbers. Alarms are indicated by a lamp and buzzer. Low battery voltage is notified by a buzzer.
Inquire About This Product
basic information
Target gases: Oxygen, Hydrogen Sulfide Detection principle: Diaphragm galvanic cell type, constant potential electrolysis type Gas sampling method: Diffusion type Detection range (service range): 0–25.0 vol%, 0–30.0 ppm (up to 50.0 ppm) Resolution: 0.1 vol%, 0.5 ppm Indication accuracy: Within ±0.5 vol%, FS within ±5% Alarm settings: 1st stage: 19.5 vol% 2nd stage: 18.0 vol% 1st stage: 10.0 ppm 2nd stage: 15.0 ppm Alarm method: 1st stage: Long intermittent buzzer sound, alarm lamp flashing 2nd stage: Short intermittent buzzer sound, alarm lamp flashing Response time: Within 20 seconds, within 30 seconds Operating temperature range: -10°C to 40°C Power supply: Two AA alkaline batteries Continuous operating time: Over 50 hours (without alarm, at 20°C) Dimensions: Main unit: W66 × H195 × D29 mm (excluding protrusions) Sensor unit: Ø44 × H75 mm (excluding protrusions) Weight: Approximately 450 g (excluding batteries)
Price range
Delivery Time
Applications/Examples of results
Company information
At Ascom Co., Ltd., we rent out measuring instruments to ensure safety and security on site. We offer a variety of products, including noise and vibration measuring instruments, gas detectors, and water quality testers, so please feel free to consult us if you have any requests.