Differential pressure gauges and differential pressure transmitters for flow measurement! We provide designs based on JIS standards!
The "ORS" is a flange-integrated orifice flange that is installed by welding the piping to the flange, generating a differential pressure based on the flow rate of liquids, gases, and steam, allowing for flow measurement with differential pressure gauges and differential pressure transmitters. The orifice design is conducted as a flange-integrated type, and the orifice plate is designed and manufactured by our company based on orifice calculations in accordance with JIS standards. Additionally, differential pressure gauges and differential pressure transmitters are available as options. *For more details, please refer to the PDF materials or feel free to contact us.*
Inquire About This Product
basic information
【Specifications】 ■Model: ORS ■Manufacturing Diameter: 50A to 500A ■Measured Fluid: Liquid, Gas, Steam ■Maximum Operating Pressure: According to flange standards ■Installation Method: Integral flange type ■Pressure Extraction Method: Flange tap ■Orifice Calculation: JIS Z 8762-2:2007 ■Materials ・SUS304 (Standard) SUS316, etc. ・Flange Part: SS400 (Custom) ・Flange Part: S25C (Custom) ■Connections ・JIS 10K Flange (Standard) ・JIS 5K, 16K, 20K, 30K Flanges ・ANSI Flanges, JPI Flanges *For more details, please refer to the PDF document or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the PDF document or feel free to contact us.
catalog(1)
Download All CatalogsCompany information
Our company was founded in June 1949 as a Fluid Research Institute and began the research, manufacturing, and sales of flow meters.