High-pressure steam sterilizer for physical and chemical use 'CLG Series/CLG-DVP Series'
CLG Series: CLG-32L/40M/40L, CLG-DVP Series: CLG-32LDVP/40MDVP/40LDVP
The repeated operation feature allows for durability evaluation tests of medical equipment and other parts. The CLG-DVP series, equipped with pre-vacuum and vacuum drying functions, is currently accepting demonstrations.
The "CLG Series/CLG-DVP Series" is a high-pressure steam sterilizer with more reliable sterilization performance and enhanced safety. It features an interactive LCD display that clearly shows settings for temperature, pressure, and processes, as well as the progress status and errors, allowing for operation via keys. By detecting and calculating temperature and pressure, and repeatedly performing exhaust and heating (pulse exhaust method), it ensures optimal saturated steam sterilization that adapts to the load conditions of the items being sterilized. Additionally, the CLG-DVP series is equipped with a "pre-vacuum function" to remove residual air and a "vacuum drying function" to prevent bacterial contamination after sterilization, enabling more reliable sterilization. It also comes standard with a repeat operation mode, making it suitable for durability evaluation tests of medical equipment and other items. 【Features】 ■ Lid and interlock that lock until a safe state is reached after sterilization ■ Exhaust bottle is conveniently located at the front for easy access (CLG) ■ Standard cooling fan ■ Equipped with pre-vacuum/vacuum drying function using a water-sealed vacuum pump (CLG-DVP) ■ Media warming function to maintain the culture medium at an appropriate temperature after sterilization ■ Calendar timer included *For more details, please refer to the PDF materials or feel free to contact us.
Inquire About This Product
basic information
■ Sterilization temperature/time: 100℃ to 140℃ / 0 to 48 hours 00 minutes or continuous ■ Dissolution temperature/time: 40℃ to 90℃ / 0 to 48 hours 00 minutes or continuous ■ Holding temperature/time: 40℃ to 60℃ / 0 to 48 hours 00 minutes or continuous ■ Drying temperature/time (CLG-DVP only): 60℃ to 150℃ / 0 to 99 hours 59 minutes or continuous ■ Capacity: 54 to 105L ■ Required utilities: Power supply (AC100V, 20A or AC200V, 30A or more) Water supply (CLG-DVP only) Drainage system (CLG-DVP only) 【Manufacturer optional features】(not retrofittable) ■ Automatic water supply system (with preheat function)… Achieves significant labor savings and time reduction ■ Exhaust air filter system (pore size 0.2μm)… Biohazard countermeasures (installable only on standard models) ■ GMP-compliant specifications… Recorder installation 【Dealer optional features】(retrofittable) ■ Product temperature sensor ■ Printer ■ Serial communication port RS-232C, data logging system ALP-LOGGER *For more details, please refer to the PDF document or feel free to contact us.
Price information
¥646,000 to ¥1,428,000 Prices may vary depending on the sales channel, so please feel free to contact us.
Price range
P4
Delivery Time
P4
Applications/Examples of results
■ For sterilization and drying applications of media, equipment, and cleanroom garments in pharmaceutical companies ■ For bacterial testing applications in food manufacturers ■ For multipurpose use in university laboratories ■ For sterilization evaluation of porous and tubular materials ■ For durability evaluation of equipment in dental tool manufacturers ■ For pretreatment of rubber injection molded products ■ For durability evaluation of parts used in medical devices ■ For durability evaluation of RFID tags attached to medical instruments ■ For durability evaluation of medical wires ■ For weather resistance testing of electrical materials
Detailed information
-
ALP-LOGGER (Optional) The data logging system "ALP-LOGGER" supports daily sterilization management by capturing temperature-time, can internal pressure, process transitions, abnormal outputs, and more from the sterilizer to a PC. The captured data can be output as a "temperature-time" graph and can also be processed in Microsoft Excel. A CD-ROM, as well as cables and connectors for connecting to the PC's USB, are also included.
-
Product temperature sensor (optional) During operation, it can output the temperature near the sterilized items inside the can or the center temperature of the liquid to the LCD panel or a dedicated printer (optional). Additionally, with product temperature control operation, it is possible to start the sterilization timer from the moment the sensor's indicated value reaches the set temperature, allowing for more reliable sterilization.
-
Printer (Optional) It prints the date and time when the operation starts, as well as the time, control temperature, and product temperature (only when equipped with an optional product temperature sensor) at regular intervals.
catalog(1)
Download All CatalogsCompany information
Alpu Co., Ltd. primarily engages in the design, manufacturing, and sales of sterilization equipment and culture equipment for bio-research and medical use in Hamura City, Tokyo. Additionally, the company is involved in the design, manufacturing, and sales of dryers and incubators for low-temperature and high-temperature processing, as well as the design, manufacturing, and sales of clean drying and dry heat sterilizers (for scientific use) and reliability testing equipment for semiconductors and other applications.