Do you have any concerns regarding "IoT implementation at the site" or "efficiency improvements in inspection and maintenance operations"? - In the past, I tried using wireless technology for data collection on-site, but the signal didn't reach without placing a relay... - Wiring work costs a lot of money... - The monthly fees for software and cloud services seem to be quite high... By utilizing LoRa wireless devices, these issues can be resolved. - Long-distance communication of up to 5 km is possible! - Since it's a wireless device, there are no wiring costs! For wiring over approximately 50 meters, LoRa wireless devices are more cost-effective! - There are no monthly fees since we do not use the cloud! You can operate with just the initial investment! Since its release in 2018, we have been utilized by many customers, from large manufacturing companies to medium and small factories. In this "LoRa Wireless Device Proposal Case Collection," we introduce a total of 20 actual proposal cases using LoRa wireless devices, not only showcasing the product lineup but also including examples of power monitoring, operational monitoring, and anomaly monitoring!
Inquire About This Product
basic information
【Contents】 1. LoRa Radio Product Lineup 2. System Configuration with LoRa Radios 3. Introduction of 20 Selected Case Studies
Price information
Free giveaway!
Price range
Delivery Time
P3
※If you contact us, we will send the data via email by the next business day.
Applications/Examples of results
【Case Content】 Classified into five categories: energy saving, operational monitoring, quality monitoring, anomaly monitoring, and labor saving, featuring a total of 20 carefully selected proposal examples! Examples: - Retrofitted power monitoring at the process unit level - Production efficiency counting through monitoring of downtime - Remote monitoring of wastewater quality in factories - Vibration trend monitoring of motors - Remote notification system for achieving inter-process collaboration, among many others.
Detailed information
-
IoT Gateway (with WEB server and monitoring software) Model: HLR-GW 〇 Functions - Status monitoring (graph) - Operation count - Alarm settings and output - Email notification - USB memory recording 〇 Data transfer methods HTTP, FTP, Modbus/TCP 〇 Power supply AC100V (AC adapter) 〇 Options External contact output
-
LoRa Radio Multi-Function 4-Point Model Model: HLR-A4C4 〇 Input Specifications ・Analog 4 points (DC0-20mA, DC0-10 ※ selectable settings, channel isolation) ・Contact 4 points (no voltage) ・RS-485 (Modbus compliant) 〇 Output Specifications ・LoRa Communication 920MHz Band ・Alarm output 1 point 〇 Power Supply ・AC85-264V, DC24 (※ specified at the time of order)
-
LoRa Radio Multi-Point Model Model: HLR-A8 〇 Input Specifications Analog 8 points (DC4-20mA, DC1-5V *Specify at the time of order) 〇 Output Specifications LoRa Communication 920MHz Band 〇 Power Supply AC85-264V
-
LoRa Radio Analog Single Point Model Model: HLR-A1 〇 Input Specifications Analog Single Point (DC0-20mA, DC0-10V *Selectable setting) 〇 Output Specifications LoRa Communication 920MHz Band 〇 Power Supply AC85-264V
-
LoRa Radio Device Analog Single Output Model Model: HLR-A1-OUT 〇 Input Specifications LoRa Communication 920MHz Band 〇 Output Specifications Analog Single Point (DC0-20mA, DC0-10V *Selectable Setting) 〇 Power Supply AC85-264V
-
LoRa Radio Device, 1 Contact Point Model Model: HLR-C1 〇 Input Specifications 1 Contact Point (No Voltage) 〇 Output Specifications ・LoRa Communication, 920MHz Band ・1 Contact Point (No Voltage) 〇 Power Supply AC 85–264V
-
LoRa Radio Device, 2-Point Contact Model Model: HLR-C2 〇 Input Specifications 2-Point Contact (No Voltage) 〇 Output Specifications ・LoRa Communication, 920MHz Band ・2-Point Contact (No Voltage) 〇 Power Supply AC 85–264V
-
LoRa Radio HLR-RS485 Model 〇 Input Specifications RS-485 (Modbus compliant) 〇 Output Specifications LoRa Communication 920MHz Band 〇 Power Supply AC 85–264V
-
LoRa Wireless Repeater Model: HLR-RPT 〇 Input Specifications LoRa Communication 920MHz Band 〇 Output Specifications LoRa Communication 920MHz Band 〇 Power Supply AC85–264V 〇 Number of Relay Stages 1 Stage
catalog(1)
Download All CatalogsCompany information
Our company operates globally across a wide range of fields and industries, supporting the energy conservation of important infrastructure for society and industry, reducing environmental impact, stabilizing quality, improving productivity, and ensuring safety in daily life. We are leveraging the technologies and know-how we have cultivated so far to expand into the fields of nursing care and renewable energy. Moving forward, with "measuring, supporting, and creating" as our core concept, we will create solutions that address the challenges faced by businesses and society, contributing to the development of a society filled with trust and security.