Opening fixed RF current monitoring probe, opening 25mm
TekBox Digital Solutions Inc. TBCP1-200 / TBCP1-250 / TBCP1-500
RF current monitoring probe with fixed opening to expand the scope of EMC pre-compliance test products.
【TBCP1-200】 The TBCP1-200 is a fixed aperture RF current monitoring probe. The probe has a 3dB bandwidth of approximately 200 MHz. The aperture of the RF current monitoring probe is 25 mm. Its transmission impedance is > 14 dB ohms in the range of 40 kHz to 200 MHz. 【TBCP1-250】 The TBCP1-250 is a fixed aperture RF current monitoring probe. The probe shows a very flat response with a 3dB bandwidth of 250 MHz and is characterized and usable in the frequency range of 30 kHz to 250 MHz. The aperture of the RF current monitoring probe is 25 mm. Its transmission impedance is > 16 dB ohms in the range of 300 kHz to 250 MHz. 【TBCP1-500】 The TBCP1-500 is a fixed aperture RF current monitoring probe. The probe shows a very flat response with a 3dB bandwidth of 500 MHz and is characterized and usable in the frequency range of 30 kHz to 500 MHz. The aperture of the RF current monitoring probe is 25 mm. Its transmission impedance is > 15 dB ohms in the range of 300 kHz to 500 MHz.
Inquire About This Product
basic information
【TBCP1-200 Specifications】 Characteristic frequency range: 10 kHz to 200 MHz Aperture diameter: 25 mm Outer diameter: 76 mm Height: 31 mm Weight: 320 g Connector type: N female Transmission impedance: 3 to 17 dBΩ Maximum primary current (DC – 400 Hz): 80 A Maximum primary current (RF): 3 A Maximum center temperature: 125°C 【TBCP1-250 Specifications】 Characteristic frequency range: 30 kHz to 250 MHz Aperture diameter: 25 mm Outer diameter: 76 mm Height: 31 mm Weight: 320 g Connector type: N female Transmission impedance: 0 to 18 dBΩ Maximum primary current (DC – 400 Hz): 80 A Maximum primary current (RF): 3 A Maximum center temperature: 125°C 【TBCP1-500 Specifications】 Characteristic frequency range: 30 kHz to 500 MHz Aperture diameter: 25 mm Outer diameter: 76 mm Height: 31 mm Weight: 320 g Connector type: N female Transmission impedance: -6 to 20 dBΩ Maximum primary current (DC – 400 Hz): 80 A Maximum primary current (RF): 3 A Maximum core temperature: 125°C
Price information
Please contact us.
Delivery Time
Applications/Examples of results
EMC Pre-compliance Test
Detailed information
-
TBCP1-200 Transmission Impedance (typ.)
-
TBCP1-200 transmission impedance (typ.)
-
TBCP1-250 Transmission Impedance (typ.)
-
TBCP1-250 Transmission Impedance (typ.)
-
TBCP1-500 Transmission Impedance (typ.)
Line up(3)
Model number | overview |
---|---|
TBCP1-200 | Characteristic frequency range: 10 kHz to 200 MHz Aperture diameter: 25 mm Outer diameter: 76 mm Height: 31 mm Weight: 320 g Connector type: N female Transmission impedance: 3 to 17 dBΩ Maximum primary current (DC – 400 Hz): 80 A Maximum primary current (RF): 3 A Maximum core temperature: 125°C |
TBCP1-250 | Characteristic frequency range: 30 kHz to 250 MHz Aperture diameter: 25 mm Outer diameter: 76 mm Height: 31 mm Weight: 320 g Connector type: N female Transmission impedance: 0 to 18 dBΩ Maximum primary current (DC – 400 Hz): 80 A Maximum primary current (RF): 3 A Maximum core temperature: 125°C |
TBCP1-500 | Characteristic frequency range: 30 kHz to 500 MHz Aperture diameter: 25 mm Outer diameter: 76 mm Height: 31 mm Weight: 320 g Connector type: N female Transmission impedance: -6 to 20 dBΩ Maximum primary current (DC – 400 Hz): 80 A Maximum primary current (RF): 3 A Maximum core temperature: 125°C |
catalog(3)
Download All CatalogsCompany information
As a company that provides unique and innovative solutions in EMC testing and general measurement, Wavecrest Corporation is active in this field. The increasingly sophisticated electronic and communication environment not only affects the performance of its products but also serves as a social infrastructure that impacts the overall safety of society, requiring high levels of safety and reliability. We aim to provide new products and solutions that the market needs, without being constrained by traditional testing methods and equipment.