By installing air supply ducts on the secondary side of ducted air conditioning units and external air handling units, ions are supplied from all indoor air supply outlets, achieving virus disinfection, deodorization, and energy-saving air conditioning.
By installing AQS in the air supply section of the ventilation system, the air quality and hygiene levels of the ventilated indoor environment will dramatically improve. Odors generated from outdoor air and indoor sources are detected and identified, and are reliably removed through oxygen ion reactions. Additionally, by measuring and detecting the generation capacity of oxygen ions, as well as indoor and outdoor air quality, air supply volume, and humidity with sensors, it is possible to quantify the invisible air and generate appropriate ions indoors, thereby constantly creating an optimal indoor environment. Furthermore, by monitoring the data measured by air measurement sensors, it is possible to confirm that the indoor air, which changes daily, is being operated hygienically. It is possible to disinfect airborne bacteria, with disinfection effectiveness data close to 90%. Installing it in the air supply duct enables infection control in indoor spaces. It is possible to reduce air conditioning airflow and hygienically increase the proportion of air that is reused (heat recovery) that is discharged outdoors. - Neutralization and removal of airborne bacteria (mold, bacteria, yeast) and odor substances (tobacco, ammonia, hydrogen sulfide). - Effectiveness against viruses, pollen, PM2.5, and VOCs, which are substances that affect the human body. - Prevention of nosocomial infections.
Inquire About This Product
basic information
Ionair Concentration Adjustment Device (ICE-A1000/2000 a/m) *The control of ion generation concentration corresponds to the variable air volume of the air conditioning unit. Furthermore, by checking the air conditions with various sensors installed in the duct and supplying the appropriate amount of ions, the indoor air cleanliness will dramatically improve. Ionair Ion Generation Module IMM Series (Small) IMK Series (Medium) IMG Series (Large) Ion Tube Length: 190 mm / 250 mm / 360 mm / 530 mm Applications: Supply Air / Extracted Air / Exhaust Treatment / Recirculated Air Installation Location: Inside Air Conditioning Unit (AHU) / Air Duct (Note) The number of ion tubes will be calculated by Ionair based on the air conditioning ventilation frequency and area volume of the target area. Please contact us for inquiries. There is no interference with the design. There is no need for daily maintenance or replenishment (annual maintenance required). Inquiries through Ipros have been suspended. Please contact us directly at: P 03 3288 3220 E info@ionair.jp
Price information
The price varies depending on the quantity.
Applications/Examples of results
Air purification / Ventilation volume suppression effect (energy saving and CO2 reduction) Inactivation effect of airborne viruses (proven products) (Implemented facilities) Hotels, stores, shopping malls, amusement facilities (casinos) Subway stations, schools, event facilities, offices, restaurants, airports Infection prevention measures in medical facilities such as nursing homes and hospitals Removal of odor substances (deodorization) - Deodorization of garbage storage rooms, cleaning facilities, and sewage treatment facilities - Air purification in laboratory animal facilities and food factories - Deodorization of smoking areas Implementation results (partial) Wynn Resorts Casino (Macau, China) Park Hyatt & Grand Hyatt Hotels (Shanghai, China) Shopping mall "dez" (Innsbruck, Austria) Zurich International Airport (Switzerland) Siemens TS (Berlin, Germany) St. Jakob-Park soccer stadium (Basel, Switzerland) Kanazawa Umimirai Library (Ishikawa Prefecture) Cantonal Hospital (Aarau, Switzerland)
Detailed information
-
This is an image of installation in a duct.
-
It is an image of being installed inside the air conditioning unit. It can be installed without damaging the ductwork.
-
This is an image of ion generation. By applying a constant high voltage to the generation tube, oxygen ions are produced from the air. Oxygen ions have properties similar to ozone, including odor removal and the ability to decompose chemical substances, but a characteristic of oxygen ions is that they have no impact on the human body.
-
This is an example of the AQS system configuration. By installing four types of sensors in the air conditioning ducts, air measurements are conducted. Based on that data, an appropriate ion concentration is generated. Additionally, the measurement data used during generation can be linked with the building management system.
Line up(3)
Model number | overview |
---|---|
IMM Series | Effective indoor space volume (300 - 800 m3) Ideal for air purification in small spaces and living rooms, as well as installation in individual rooms. |
IMK Series | This is a model designed for medium-sized spaces. It accommodates an effective room volume of 600 - 3600 m3 due to the configuration of the ion generation tube. |
IMG Series | This is a model designed for large facility spaces. It covers air purification for an entire floor and for the entire building. Effective room volume 1200 - 7200 m3 / unit Multiple IMG series units can be installed. |
catalog(2)
Download All CatalogsNews about this product(1)
Company information
Founded in 1993 under the name "LK Luftqualität AG," the company currently operates under the name "ionair." It is a Swiss company that boasts a track record of over 10,000 installations in Japan, offering deodorization, air purification, and energy-saving systems. The ionair system generates oxygen ions using the corona discharge effect. It produces fresh and clean air without the use of chemicals, ultraviolet light, or ozone. Additionally, it is designed for use in occupied environments. - Deodorization Effect - By exposing contaminated air to oxygen ions, the system oxidizes and decomposes odor molecules and VOCs, breaking down and neutralizing the substances causing odors and converting them into water and carbon dioxide. - Air Purification Effect - Indoor air is more than five times more polluted than outdoor air. Ionair decomposes and neutralizes harmful substances such as chemicals, pollen, and viruses using oxygen clusters that have no adverse effects on the human body. - Energy-Saving Effect - By equipping the ducts of first-class ventilation air conditioning units, the system can reduce the airflow of the air conditioning unit. Furthermore, by increasing the amount of recirculated air and reusing exhaust air, it can significantly lower electricity costs associated with heating and cooling.