Do you need a system that can quickly perform gamma-ray analysis anywhere in an emergency? Please consider the Quant4 GR1.
In emergencies, the time lost in transporting sampled materials to a well-equipped lab for analysis and the risk of contamination of the lab and exposure to workers due to bringing unknown samples into the lab must be minimized. Quant4 GR1 is a gamma-ray analysis device equipped with the KromeK company's CZT detector GR1+, which has already proven effective in many field sites, research institutions, and universities. The room-temperature semiconductor detector allows for measurements without waiting or even while in transit. While its energy resolution and efficiency do not match the highest-grade Ge semiconductor detectors, its high resolution of less than 2% FWHM (at 662 keV) can accommodate many nuclides in the field.
Inquire About This Product
basic information
Detector Resolution: Below 2% (at 662 keV) Energy Range: 30 keV - 3 MeV MCA: 4096 channel MCA Weight: Approximately 22 kg Dimension: 300 mm φ x 210 mm (H) excluding protrusions Shield: 10 mm Pb 3 mm Cu
Price range
Delivery Time
Applications/Examples of results
- Emergency site analysis - Environmental monitoring - Waste disposal etc. For inquiries, please contact niki__sales@nikiglass.com.
catalog(2)
Download All CatalogsCompany information
Niki Kogei Co., Ltd. imports and sells various products, including radiation measurement devices, X-ray non-destructive testing equipment, goniometers, X-ray optical instruments, as well as freezers and bio-sample storage refrigerators.


![[Analysis Case] Evaluation of Material Structure of Organic EL (OLED)](https://image.mono.ipros.com/public/product/image/74a/2000332445/IPROS6719634173671350524.jpg?w=280&h=280)


![[Data] Analysis of Polycarbonate Degradation by Reaction Thermal Decomposition](https://image.mono.ipros.com/public/product/image/820/2000700625/IPROS00006365835140416369.png?w=280&h=280)

![[Information] Product Development of I.S.C.Lab. Inc.](https://image.mono.ipros.com/public/product/image/2076701/IPROS10090015200250328856.png?w=280&h=280)

![[Applicable Example] NaI(Tl) Radiation Detector for Process Water](https://image.mono.ipros.com/public/product/image/2076701/IPROS15902933724122950975.png?w=280&h=280)
![[Application Example] CsI(Tl) Radiation Detector for Process Water](https://image.mono.ipros.com/public/product/image/2076701/IPROS9655402684431545668.png?w=280&h=280)
![[Applicable Case] Food Becquerel Counter](https://image.mono.ipros.com/public/product/image/2076701/IPROS14155750067446058970.png?w=280&h=280)