It can be quickly measured during the surface film processing of industrial products, ensuring the appropriate thickness is maintained.
Equipped with three calibration modes for accurate film thickness measurement High resolution and wide measurement range (up to 1500μm) Alerts when set values are exceeded Displays maximum, minimum, standard deviation, and average values Display can switch between five types of screens, including graphs Includes continuous measurement mode in addition to normal measurement mode Screen automatically rotates according to the measurement position Easy-to-read measurement values displayed on a color LCD screen Energy-saving structure with automatic OFF function (2 minutes, 5 minutes, 10 minutes, 30 minutes, none) Battery level icon display to indicate charging status Additional charging USB port alongside the regular power terminal for emergency charging Can store 15 measurement values in 100 separate records internally Compact handheld type with excellent portability and operability
Inquire About This Product
basic information
Measurable Substrate: Iron, Non-ferrous Measurement Range: Iron, Non-ferrous: 0 to 1500μm Measurement Resolution: <100μm: 0.1μm >100μm: 1μm Measurement Accuracy: <150μm: ±5μm >150μm: ±3% + 1μm Minimum Measurement Range: Iron: 12mm Non-ferrous: 50mm Minimum Curvature Radius (Convex, Concave): Iron: Convex 2 mm; Concave 11 mm Minimum Substrate Thickness: Iron, Non-ferrous: 0.5 mm Measurement Units: μm, mm, mils Measurement Mode: Single Measurement, Continuous Measurement Calibration Mode: Basic Calibration, Measurement Value Calibration, Zero Point Data Log Display: 5 types (Standard, Graph of Recent Values, Statistics, Final Value, Bar Graph) Functions: Display Lighting, Auto OFF (2 min, 5 min, 10 min, 30 min, none), Calibration, Memory, Screen Auto Rotation, Text Color (6 colors) Interface: USB Measurement Result Memory: 100 readings Display: 2.25-inch Color LCD Display Measurement Environment Temperature: 0 to 50°C Power Supply (Battery): 3 x 1.2V AA Ni-MH 800 mAh Power Supply (Main Adapter): Primary: 100–240V; 50/60 Hz; 0.45 A Secondary: 5V DC; 1 A
Price range
Delivery Time
Applications/Examples of results
It can quickly measure the surface film processing of industrial products and maintain the appropriate thickness. *For more details, please refer to the PDF document or feel free to contact us.
Detailed information
-
Hard case, calibration resin plate set
-
Calibration and operation confirmation resin plate
Company information
Our company handles research and development equipment, manufacturing test facilities, medical devices, survey equipment, and more. We are responsible for introducing world-leading automation and process rationalization technologies to industrial sites in Japan, contributing to the shortening of operations. Please feel free to contact us if you have any requests.