Measuring the time until the pressure drop point! A test to measure the oxidation stability of automotive gasoline.
We would like to introduce our "Gasoline Oxidation Stability" test. A metal pressure-resistant container filled with the sample is pressurized with oxygen and immersed in a constant temperature bath at 100°C. We observe the pressure changes in the cylinder and measure the time until the pressure drops. This serves as an indicator of the tendency for gum formation during storage. Please feel free to contact us when you need our services. 【Test Details】 ■ Item Number: F142 ■ Required Volume: 100ml ■ Standard Number: JIS K2287 ■ Main Target Oil Type: Gasoline *For more details, please refer to the related links or feel free to contact us.
Inquire About This Product
basic information
For more details, please refer to the related links or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please refer to the related links or feel free to contact us.
catalog(1)
Download All CatalogsCompany information
Our company leverages the technology and experience gained over many years in the testing and analysis of petroleum products to meet the diverse needs of our customers. We have cultivated various technologies through the testing and analysis of petroleum products and engine testing. Based on this technology, we contribute to our customers' businesses by undertaking "fuel testing" and "lubricating oil testing." To respond to the changing needs of our customers over time, we aim to be at the forefront of advancing analytical technologies and grow into a company trusted by our customers.