Improving the performance of centrifugal pumps! A case study applying general-purpose thermal fluid analysis software.
We would like to present a case study where the general-purpose thermal fluid analysis software "AICFD" was used to analyze the head and shaft power of a centrifugal pump, comparing the results with experimental values. The mesh model adopted an unstructured mesh with a total cell count of 1.2 million. When comparing the experimental values with the analysis results, a deviation of 1.70% was confirmed for both output (kW) and head (m). 【Analysis Conditions】 ■ Inlet Condition: 69.46 [L/s] ■ Outlet Condition: Static Pressure 0 [Pa] ■ Rotational Speed: 980 [RPM] ■ Turbulence Model: Standard k-epsilon *For more details, please download the PDF or feel free to contact us.
Inquire About This Product
basic information
For more details, please download the PDF or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
For more details, please download the PDF or feel free to contact us.
catalog(2)
Download All CatalogsCompany information
Our company focuses on the development, sales, and support of various CAE software with "AI x Optimization" as a key concept, and we offer a wide range of services including contract analysis and consulting. The software we provide can also be customized according to our customers' requests. We aim to contribute to manufacturing by providing better products and services in product development, design, and research.