Essential for aggressive thermal design! Toyota's in-house thermal flow sensor "Energy flow"
This is a heat flux sensor used by Toyota Motor Corporation in the field of car development. It can easily measure the "heat flux" necessary to elucidate the mechanisms of temperature change.
Inquire About This Product
basic information
▼Operating Temperature Range -30℃ to +150℃ ▼Sensitivity Accuracy Repeatability error < ±2% RSO (reading value) ▼Temperature Characteristics < ±5% at 0 to +100℃ based on room temperature ▼Thermal Resistance Value 0.0013 m²·K/W ▼Minimum Detectable Heat Flux Approximately 10 W/m² ▼Maximum Detectable Heat Flux ±14.6 kW/m² *The heat flux that passes when the temperature difference between the front and back of the detection part is guaranteed at -30℃ and +150℃ ▼Compressive Load Resistance 4 MPa ▼Minimum Allowable Curvature < r30 mm
Price range
Delivery Time
※Prices and delivery times vary depending on specifications. Please contact us through the official website.
Applications/Examples of results
- Thermal balance evaluation and thermal damage design for engines and transmissions - Quantitative evaluation of the comfort of ventilation systems for automotive seats - Evaluation of heat generation from motors and batteries - Evaluation of insulation performance in refrigerated warehouses - Understanding the heat gain from window glass and frames, and verifying the effectiveness of insulation measures
Line up(7)
Model number | overview |
---|---|
T-Standard S | Width 10mm × Length 12.5mm × Thickness 0.25mm |
T-Standard M | Width 10mm × Length 44mm × Thickness 0.25mm |
T-Standard L | Width 10mm × Length 66.5mm × Thickness 0.25mm |
T-Standard SS | Width 5.5mm × Length 68mm × Thickness 0.25mm |
T-Standard □20 | Width 20mm × Length 20mm × Thickness 0.25mm |
T-Standard □40 | Width 40mm × Length 40mm × Thickness 0.25mm |
T-Standard 5060 | Width 50mm × Length 60mm × Thickness 0.25mm |
catalog(1)
Download All CatalogsCompany information
In the business development area of Toyota Motor Corporation, we are developing technology solution businesses that leverage the technologies and know-how cultivated over many years of car manufacturing. The heat flow sensor "Energy flow," which can measure "heat flux" essential for elucidating the mechanisms of temperature changes with high sensitivity and simplicity, is an in-house sensor utilized in Toyota's vehicle development field. It has become an indispensable item for the development of high-efficiency thermal energy management systems/components aimed at a decarbonized society, and it is being used by customers in various industries, including the automotive sector. Please feel free to contact us when you need assistance.