Line Impedance Stabilization Network (LISN) 50µH TBL5016-2B
The TBL5016-2B is a line impedance stabilization network designed to measure conducted emissions on power lines in the frequency range of 9 kHz to 30 MHz, in accordance with the CISPR 16-1-2 standard. This device is designed for testing single-phase AC power equipment with a maximum power supply voltage of 250V and 16A. Conducted noise can be measured on both the phase and neutral lines. The TBL5016-2B features independent measurement outputs for each channel and allows for connections to a common mode/differential mode separator (LISN Mate), a PE switch that simulates extension cables, and artificial manual connections. This device is compatible with EUT connectors specific to each country.
Inquire About This Product
basic information
Frequency range: 9 kHz to 30 MHz Impedance: 50 Ω × (50 µH + 5 Ω) Artificial hand: 220 pF + 511 Ω Switchable PE: 50 Ω × 50 µH Line and neutral independent BNC output for CM/DM separator (LISN Mate) connection Air core inductor Line voltage: Maximum 250V / 50/60 Hz or DC Maximum current: 16 A @ 23℃ EUT socket: Country-specific specifications Measurement connector: 50 Ω BNC Power connector: IEC 60320 C19 Operating temperature range: +5℃ to +40℃, relative humidity 5% to 80%
Price range
Delivery Time
Applications/Examples of results
1. Conducted Emission Test - Frequency range: 9 kHz to 30 MHz - Standards: Compliant with CISPR 16-1-2 - Standard LISN for measuring AC line noise at specified impedance - Ideal for pre-compliance applications in EMC testing 2. EMC evaluation of high current (up to 16 A) equipment Supports larger current AC devices that the TBL5008 series (8 A) cannot handle Examples: - Large home appliances - Industrial power supplies - AC motor drivers - Medical devices - Industrial controllers - Large AC adapters 3. CM/DM (Common Mode/Differential Mode) noise analysis - Independent BNC outputs for L/N - Can be combined with TekBox LISN Mate for CM/DM separation measurements - Very effective for identifying noise sources 4. Artificial Hand Test - Built-in artificial hand circuit of 220 pF + 511 Ω - Used for noise evaluation of devices touched by hand 5. Extension cable simulation using PE (Protective Earth) switch
Detailed information
-

Line Impedance Stabilization Network (LISN) 50µH TBL5016-2B
-

Line Impedance Stabilization Network (LISN) 50µH TBL5016-2B
-

Line Impedance Stabilization Network (LISN) 50µH TBL5016-2B OP
catalog(2)
Download All CatalogsCompany information
As a company that provides unique and innovative solutions in EMC testing and general measurement, Wavecrest Corporation is active in this field. The increasingly sophisticated electronic and communication environment not only affects the performance of its products but also serves as a social infrastructure that impacts the overall safety of society, requiring high levels of safety and reliability. We aim to provide new products and solutions that the market needs, without being constrained by traditional testing methods and equipment.