RE101 Loop Antenna TBRE101 30 Hz to 100 kHz
The TBRE101 is a passive receiving loop antenna used in the MIL-STD-461G RE101 test. It is employed to measure radiated emissions from electronic equipment and subsystems, including electrical cable interfaces for defense applications. The TBRE101 is used to measure low-frequency magnetic field emissions at a position 7 cm around the device under test (DUT). The test frequency range is from 30 Hz to 100 kHz. The test setup and measurement procedures are specified in Section 5.17 of MIL-STD-461G. The TBRE101 consists of a coil with a diameter of 13.3 cm, wound 36 times with seven strands of 41 AWG litz wire inside a shield. The DC resistance of the loop winding is 10Ω. This loop receives magnetic field radiation that is perpendicular to the internal plane and generates a voltage signal at the loop's output port that is proportional to the intensity of the B field/H field radiation. As a calibration option accessory, the TekBox TBCCP1-2K70 coaxial RF current monitoring probe (transducer) is available, which has a flat transfer impedance of 0 dBΩ (1V/A) over a frequency range of 9 kHz to 30 MHz at a 50Ω load.
Inquire About This Product
basic information
Antenna Type: Receiving Loop Frequency Range: 30 Hz to 100 kHz (Usable Frequency Range: 10 Hz to 1 MHz) Standards: MIL-STD-461G / RE101 Loop Diameter: 13.3 cm Loop Structure: 7 strands of 41 AWG litz wire twisted together, 36 turns Loop Coil DC Resistance: 10 Ω (Nominal Value) Loop Coil Self-Inductance: 385 µH Output Connector: N-type female, 50 Ω Antenna Conversion Factor: Within ±3 dB compared to the theoretical value of the standard RE101 loop per MIL-STD-461G Dimensions: Length × Width × Height: 10.62 cm × 15.2 cm × 19.1 cm (4.18 inches × 5.98 inches × 7.52 inches) Weight: 0.5 kg (1.1 pounds)
Price range
Delivery Time
Applications/Examples of results
【Applications】 - MIL-STD-461G RE101 Test Used for measuring low-frequency magnetic field emissions from 30 Hz to 100 kHz. - EMC evaluation for defense and aerospace electronic equipment Measuring magnetic field radiation from cables and enclosures at a distance of 7 cm. - Leakage checks and research applications for low-frequency magnetic fields Usable range from 10 Hz to 1 MHz. 【Track Record】 - Defense and aerospace electronic equipment manufacturers (EMC testing compliant with MIL standards) - EMC testing laboratories (RE101 evaluation services) - Industrial equipment manufacturers (low-frequency magnetic field checks for motors and power supplies) - Universities and research institutions (education and research in magnetic field measurement)
Detailed information
-

RE101 Loop Antenna TBRE101 30 Hz to 100 kHz
-

RE101 loop antenna TBRE101 30 Hz to 100 kHz
-

RE101 loop antenna TBRE101 30 Hz to 100 kHz
catalog(1)
Download All CatalogsCompany information
As a company that provides unique and innovative solutions in EMC testing and general measurement, Wavecrest Corporation is active in this field. The increasingly sophisticated electronic and communication environment not only affects the performance of its products but also serves as a social infrastructure that impacts the overall safety of society, requiring high levels of safety and reliability. We aim to provide new products and solutions that the market needs, without being constrained by traditional testing methods and equipment.