List of Control and Electrical Equipment products
- classification:Control and Electrical Equipment
181~225 item / All 50603 items
Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!
- Other conveying machines
Presentation of explanatory materials on JIS and ISO standards. We propose suitable safety barriers from a rich product series! Free rental of demo kits.
- Other safety and hygiene products
An easy-to-understand explanation of pumps that provide speed, pressure, and potential energy to liquids for tasks such as transfer, pumping, and sales expansion!
- Chiller
An easy-to-understand overview of valves that control fluid flow rate, direction, pressure, and more!
- Chiller
A clear explanation of heat exchangers that efficiently transfer thermal energy using fluids such as gases and liquids!
- Chiller
Difficult-to-check internal equipment piping. A clear explanation of the basics of "piping system diagrams" used to understand the overall picture and specifications of that equipment piping!
- Chiller
When looking at the piping system diagram, cooling equipment appears. This article clearly presents the various types of cooling equipment, including their structures and principles!
- Chiller
Enclose the transport and assembly processes on the line with a booth, and install a precision air conditioning unit and a fan filter unit together to achieve a class below 10,000 and work temperature...
- air conditioning
【Amazing Dehumidification Ability!】Instant dry air supply possible with just the cooler! The "PAU-AZ2000SE-DR" can be used as a drive booth or dry air supply unit.
Precision air conditioning units enable energy-efficient and highly accurate management of temperature, humidity, and cleanliness through "local air conditioning," which conditions only limited spaces. This time, we would like to introduce the precision air conditioning unit specialized in dehumidification, the "PAU-AZ2000SE-DR"! The PAU-AZ2000SE-DR adopts Apiste's unique "MAX-DRY operation method," allowing for dehumidification of absolute moisture content by ▲65% using only the refrigeration cycle, which was previously considered difficult. For example, it can dehumidify intake air from 27°C and 70% humidity to 23°C and 30% humidity in a short time after starting operation. It can also be used for applications that previous precision air conditioning units could not accommodate, so if you are interested, please feel free to contact us. 【Application Examples】 - As a dry air conditioning unit when using hygroscopic materials! - As a drive booth for processes using organic solvents or powders! - As a dry air supply unit for the OA intake of air conditioning equipment!
Quickly detect dust leaks from dust collectors! It helps with preventive maintenance!
- Dust collector
The dust collector "GDE Series" automatically controls airflow to prevent it from dropping! It complies with the revised regulations on welding fumes! Airflow management is possible, and filter replacement is not needed for an extended period!
We would like to propose a new high-performance dust collector from Apiste. ■ Capable of capturing fumes As of April 1, 2021, a revision to the specialized regulations has been implemented, requiring ventilation through a general ventilation system or equivalent measures (local exhaust systems, push-pull type exhaust systems) when performing tasks such as metal arc welding. The GDE series maximizes effectiveness in collecting fine and viscous dust, such as welding fumes, by equipping an optional fume box. ■ Long-term filter replacement is unnecessary Using an ultra-fine filter that is finer than those typically used in dust collectors, dust can be filtered on the surface of the filter. The dust filtered on the surface is reliably removed by the "Green Pulse Method," which allows for optimal dust removal, making it less likely for the filter to become clogged. ■ Operating data storage function Not only does it maintain the set airflow, but it also allows you to check the trends of airflow and differential pressure on the touch panel. Changes such as the degree of filter contamination and whether airflow has decreased can be easily monitored. If you are interested, please feel free to contact us.
【Total 72 pages】 A detailed explanation of piping and ancillary components around cooling equipment such as pumps, valves, and heat exchangers. A must-read for anyone involved in cooling equipment.
- Chiller
This includes symbols used in piping system diagrams and key points to observe in piping system diagrams!
- Chiller
<Overseas Support BOOK> Introducing translations of terms related to control panel coolers and FA sites in three languages: Japanese, English, and Chinese!
- Control Panel Cooler
【Apiste Dictionary Chinese - Compilation - Now Available】 Translates terms for control panel coolers and FA sites into Japanese, English, and Chinese! It is listed in a table format, so you can use it as a dictionary for specialized terminology!
We have released a document titled "Apiste Dictionary Chinese - Compilation Edition," which contains FA field terminology in three languages: Japanese, English, and Chinese. This document introduces translations of terms used in the FA field in Japanese, English, and Chinese. It also includes information on control panel coolers, refrigeration cycles, machine tools, and automotive terminology. It can be used as a reference for those who frequently deal with overseas customers. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (Excerpt)] ■vol.1 index - Control panel coolers - Refrigeration cycles ■vol.2 index - Control panel cooler ENC-GR series ■vol.3 index - Machine tools
<Overseas Support BOOK> Introducing translations of terms related to control panel coolers and FA sites in three languages: Japanese, English, and Thai!
- Control Panel Cooler
【Apiste Dictionary Thai Language - Compilation - Now Available】 Translates terms related to control panel coolers and FA sites into Japanese, English, and Thai! It is listed for use as a dictionary of specialized terminology!
We have released a document titled "Apiste Dictionary Thai - Compilation Edition," which includes FA field terminology in three languages: Japanese, English, and Thai. This document introduces translations of terms used in the FA field in Japanese, English, and Thai. It also includes information on control panel coolers, refrigeration cycles, machine tools, and automotive terminology. It can be used as a reference for those who frequently deal with overseas customers. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (Excerpt)] ■ vol.1 index - Control panel coolers - Refrigeration cycles ■ vol.2 index - Control panel cooler ENC-GR series ■ vol.3 index - Machine tools
Apiste proposes the high-performance dust collector "GDE Series," suitable for the collection of welding fumes.
- Dust collector
◆◆Free Progressing◆◆ Latest technical document "Basic Dust Control Measures" *Also ideal for welding fume control!
"The Basics of Dust Control" explains the fundamental knowledge related to dust for those engaged in work environments where dust is generated. It covers appropriate dust control measures to maintain health and comfort at work, including knowledge about dust, regulations, methods for suppressing and removing dust, and other essential information related to dust. It also includes details about the revision of specific regulations in April 2021. This book summarizes dust control measures to prevent health disorders, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (Excerpt)] ■ Health disorders caused by dust ■ Dust control measures ■ Management of dust-related work ■ Regulations concerning dust ■ About the revision of specific regulations in April 2021 (welding fumes)
Outdoor environmental measuring instruments are experiencing heat troubles! Ken, the cooler for control panels, appears before designers who are troubled by fundamental countermeasures! *Manga materia...
- Control Panel Cooler
"Manga Material 'Save the Environmental Measuring Instruments! "Ken the Control Panel Cooler"' Now Available" Easy to read in manga format! An explanation of outdoor control panel coolers!
We have released a document titled "Save the Environmental Measuring Instruments! 'Ken the Control Panel Cooler'" that explains outdoor control panel coolers in an easy-to-understand manga format. Are there any of you who are worried about outdoor control panels causing heat-related issues? This document introduces Apiste's outdoor control panel cooler to design engineers facing the same concerns and summarizes the content leading to a solution in manga form. We clearly explain the features of the outdoor control panel cooler, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■Trouble cases of outdoor environmental measuring instruments ■Features of outdoor control panel coolers
Information on the pipe sizes and flow rate guidelines used when circulating cooling water is provided!
- Chiller
A clear explanation of the key points and precautions when assembling the actual piping layout!
- Chiller
Various components included in the piping route. This time, we will clearly explain the points regarding component selection and installation locations based on the piping system diagram!
- Chiller
Solve the issue of oil mist leaking from the mist collector exhaust with a smoke catch filter that doesn't require long-term replacement! Improve the environment without increasing labor.
- Oil Mist Collector
Durable PCU-SL and PCU-R that supports -10 to 80°C. Suitable for both cooling and heating! Both series can be used interchangeably according to each site.
- Chiller
[Data Release] We have published "How to Choose a Chiller to Avoid Problems Later"!
When selecting a chiller, it is important to carefully consider the usage conditions, usage situation, and the chiller's functions, performance, and specifications. Neglecting the selection process may result in the chiller not performing as expected after it is put into use, potentially leading to issues with the equipment or the chiller itself. Additionally, the selection of a chiller requires not only the work (cooling target) temperature and heat load but also factors such as the piping lift. Therefore, compared to other equipment and devices, selecting the appropriate chiller model is more challenging and prone to problems. In this volume, we will clearly introduce the method for selecting a chiller. 【Contents (Excerpt)】 ■ Selection Step 1: Determine the temperature of the circulating water ■ Selection Step 2: Decide on the cooling method ■ Selection Step 3: Determine the cooling capacity ■ Selection Step 4: Determine the pump capacity *If you have any questions, please feel free to contact us.
With an ultra-wide range specification of -10℃ to 80℃, it can handle tests that require a variety of temperatures with just one unit.
- Chiller
[Case Study of Solution Proposal] Reducing the number of chillers for testing equipment with diverse temperature requirements! A catalog explained in 6 pages of manga is now available!
We are currently publishing a catalog showcasing examples that are possible only because of Apiste's expertise in both environmental improvement and air conditioning/temperature control. 【Solution Proposal Examples】 ■ Conventional Method - Using two chillers divided into low-temperature and high-temperature ranges ■ Issues - Difficult temperature control due to the use of two chillers - Initial costs for two units - Requires installation space for two units ■ Ideal Condition - One chiller that can handle both low and high-temperature ranges - High-precision water temperature control ■ Apiste's Proposal - Use one ultra-wide range chiller from the PCU-R series, capable of -10℃ to 80℃ ■ Benefits - One chiller covers both low and high-temperature ranges - Achieves temperature control with high precision of ±0.05℃ + Double safety pan structure for peace of mind in case of emergencies + Standard RS232C communication for remote control capability + Use of external temperature sensors allows for cascade control *For more details, please refer to the related product catalog or feel free to contact us.
The mixing process of raw materials found in food factories. A clear explanation of how to read complex equipment piping diagrams and methods for improving cooling!
- Chiller
Hydraulic systems are common in many workplaces. This publication clearly explains how to interpret the schematic of this hydraulic system and improve cooling from the current state!
- Chiller
A detailed explanation of air conditioning methods in temperature-controlled rooms, the history and mechanisms of air conditioners, and clean rooms, covering everything from the basics to specialized ...
- Other air conditioning equipment
Introducing Precision Air Conditioning: It enables high-precision and wide-ranging management of temperature, humidity, and cleanliness with localized air conditioning!
Introducing Apiste's precision air conditioning unit "PAU Series"! Precision air conditioning units can create and blow out air with set temperature and humidity. They boast a control accuracy of ±0.1°C and ±0.5%, and can maintain constant temperature and humidity, as well as cooling, heating, humidifying, and dehumidifying with just one unit. By combining it with the optional clean fan filter unit, you can also manage cleanliness levels. ■ Achieve high-precision temperature and humidity control! By utilizing "local air conditioning" that conditions only the necessary space, it is possible to achieve very stable air conditioning with a temperature accuracy of ±0.1°C and humidity accuracy of ±0.5% RH. ■ Significant cost reduction compared to whole space air conditioning! By narrowing down the target space, significant reductions in installation costs can be achieved. Additionally, due to being local air conditioning, power costs can also be reduced. Furthermore, the latest precision air conditioning units use non-Freon refrigerants, making them exempt from the Freon emission control law. If you are interested, please download the PDF from the related catalog below or feel free to contact us.
A detailed explanation of the selection methods for chillers, how to handle scaling, and information about piping and pumps, from basic to specialized knowledge!
- Chiller
[Data Release] We have published "How to Choose a Chiller to Avoid Problems Later"!
When selecting a chiller, it is important to carefully consider the usage conditions, usage situation, and the chiller's functions, performance, and specifications. Neglecting the selection process may result in the chiller not performing as expected after it is put into use, potentially leading to issues with the equipment or the chiller itself. Additionally, the selection of a chiller requires not only the work (cooling target) temperature and heat load but also factors such as the piping lift. Therefore, compared to other equipment and devices, selecting the appropriate chiller model is more challenging and prone to problems. In this volume, we will clearly introduce the method for selecting a chiller. 【Contents (Excerpt)】 ■ Selection Step 1: Determine the temperature of the circulating water ■ Selection Step 2: Decide on the cooling method ■ Selection Step 3: Determine the cooling capacity ■ Selection Step 4: Determine the pump capacity *If you have any questions, please feel free to contact us.
Includes a total of 15 themes such as temperature and humidity management, and basic knowledge around cooling equipment. The use of PQ diagrams and how to select chillers are also explained in an easy...
- Chiller
[Data "Hatena Magazine: Local Air Conditioning & Chiller Edition" Now Available] A clear explanation of temperature and humidity management and cooling equipment!
We have published a document explaining air conditioning and cooling water systems titled "Hatena Magazine: Local Air Conditioning & Chillers Edition." This document provides easy-to-understand explanations of basic knowledge about constant temperature rooms and clean rooms, as well as related information about cooling equipment, divided into 15 themes. Additionally, we introduce the differences between general air conditioning and local air conditioning, as well as how to select a chiller. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (excerpt)] ■ What is a constant temperature room? ■ What is humidity? ■ How to select a chiller ■ What are the components of water?
A detailed explanation of the importance of heat countermeasures, methods of countermeasures, and coolers for control panels, from the basics to specialized knowledge!
- Control Panel Cooler
"Renewal of the Control Panel Heat Exchanger Catalog" Introducing the ENH series heat exchangers for control panels that are useful for heat dissipation and dust prevention!
The ENH series heat exchangers for control panels perform heat exchange due to the temperature difference between the inside and outside of the panel, allowing for heat dissipation from the control panel. Unlike heat dissipation fans, using the control panel in a sealed state enables heat dissipation while keeping it dustproof, providing a more reliable heat management solution. At Apiste, we offer two types of heat exchangers: heat pipe type and plate type. The heat pipe type achieves ultra-high efficiency and miniaturization through "super thermal conductive pipes." The plate type enables efficient heat dissipation with the "next-generation heat dissipation module." The documentation includes more detailed features, specifications, and dimensional drawings, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents Included] ■ Lineup of ENH series heat exchangers for control panels ■ Features of heat pipe type heat exchangers ■ Features of plate type heat exchangers ■ Specifications ■ Dimensional drawings ■ Standard panel cut drawings
A detailed explanation of the effects of hydraulic oil temperature rise on equipment, hydraulic pressure, and machine tools!
- Chiller
[Case Study of Solution Proposal] Implemented oil temperature management for hydraulic units, achieving stable operation of equipment! A catalog with a simple explanation in 6 pages of manga is now available!
We are currently publishing a catalog showcasing examples that are possible only because of Apiste's expertise in both environmental improvement and air conditioning/temperature control. It would be problematic if the oil temperature rises, causing the hydraulic unit to overheat and halting production. An increase in oil temperature can lead to seal degradation and pump failure. 【Proposed Solutions】 ■ Conventional Method - Use of a natural radiation-type hydraulic unit ■ Issues - During summer and other times of high outside temperatures, the heat dissipation efficiency decreases, leading to an increase in oil temperature - Oil leaks occur due to seal degradation - High maintenance costs due to pump failures ■ Ideal Condition - The oil temperature of the hydraulic unit is maintained below a certain temperature year-round - No oil leaks occur - Pumps do not frequently fail - Production is not halted due to pump replacement maintenance ■ Apiste's Proposal - Installation of the VSC-N series oil chiller ■ Benefits - Achieves oil temperature management for the hydraulic unit - Resolves oil leaks caused by seal degradation - Reduces time and costs for pump replacement + Additional: Implement preventive maintenance with external output for oil temperature alarms *For more details, please refer to the related product catalog or feel free to contact us.
It's now common for oil chillers to be non-Freon! It's possible to eliminate the cost burden associated with Freon.
- Chiller
[Case Study of Solution Proposal] Implemented oil temperature management for hydraulic units, achieving stable operation of equipment! Easy explanation in 6 pages of manga!
This is a case that is possible precisely because Apiste handles both environmental improvement and air conditioning/temperature control. It would be problematic if the oil temperature rises and the hydraulic unit becomes overheated, causing production to stop. An increase in oil temperature can lead to seal degradation and pump failure. 【Proposed Solution Case】 ■ Conventional Method - Use of a natural cooling hydraulic unit ■ Issues - During summer and other times of high outside temperatures, the cooling efficiency decreases, leading to an increase in oil temperature - Oil leaks occur due to seal degradation - High maintenance costs due to pump failures ■ Ideal Condition - The oil temperature of the hydraulic unit is maintained below a certain temperature year-round - No oil leaks occur - Pumps do not frequently fail - Production is not halted due to pump replacement maintenance ■ Apiste's Proposal - Installation of the compressor-type oil chiller VSC-N series ■ Benefits - Realization of oil temperature management - Resolution of oil leaks caused by seal degradation - Reduction in time and costs for pump replacement +α Implementation of preventive maintenance with external output for oil temperature alarms (IoT compatible) *For more details, please refer to the related product catalog or feel free to contact us.
Equipped with a dashcam function! Automatically records temperature and errors, which can be used for troubleshooting in case of emergencies.
- Chiller
[New Chiller Catalog Now Available] Introducing the Apiste Chiller lineup!
Introducing our comprehensive lineup of chillers that meet all your needs! ■ Non-Freon Chiller PCU-NE Series - Uses non-Freon refrigerant R1234yf, exempt from the Freon emission suppression law - Industry-first drive recorder and time calendar function ■ Wide Range Chiller PCU-R Series - Wide range of -10 to 80℃ - Class-leading accuracy of ±0.05℃ ■ High Durability Chiller PCU-SL Series - Does not stop even in high-temperature environments - Usable outdoors
Durability that doesn't stop even in high-temperature environments of 45°C! A user-friendly chiller that excels in usability!
- Chiller
[New Chiller Catalog Now Available] Introducing the Apiste Chiller lineup!
Introducing our comprehensive lineup of chillers that meet all your needs! ■ Non-Freon Chiller PCU-NE Series - Uses non-Freon refrigerant R1234yf, exempt from the Freon emission suppression law - Industry-first drive recorder and time calendar function ■ Wide Range Chiller PCU-R Series - Wide range of -10 to 80℃ - Class-leading accuracy of ±0.05℃ ■ High Durability Chiller PCU-SL Series - Does not stop even in high-temperature environments - Usable outdoors
Significant reduction in installation and operating costs! By using "local air conditioning" that only conditions limited spaces, it enables energy-saving and high-precision management of temperature,...
- Temperature and Humidity Control
Announcement of the Publication of the Comprehensive Catalog for Precision Air Conditioning Units: Introducing the latest catalog featuring all models of Apiste's precision air conditioning units, the "PAU Series"!
[Announcement of the Publication of the Comprehensive Catalog for Precision Air Conditioning Units] Precision air conditioning units are capable of creating and blowing air at set temperature and humidity levels. They boast a control accuracy of ±0.1°C and ±0.5%, and can maintain constant temperature and humidity, as well as cooling, heating, humidifying, and dehumidifying with a single unit. By combining with an optional fan filter unit, management of cleanliness can also be achieved. Recently, clean and highly precise temperature and humidity environments have been required in various fields such as manufacturing, inspection, testing, and research processes. At Apiste, we offer precision air conditioning units based on the concept of "local air conditioning & local cleanliness," which can flexibly respond to your desired constant temperature and humidity environment. Our catalog includes case studies, features, and specifications for each series, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents (Excerpt)] ■ Proposal for Local Air Conditioning ■ Applications ■ Lineup of Precision Air Conditioning Units ■ Specifications
Collects even the extremely fine oil mist without leaving any behind! A high-performance filter with high collection efficiency that does not require replacement for a long time.
- Oil Mist Collector
High-efficiency heat dissipation. A next-generation plate heat exchanger created with unique know-how!
- Heat exchanger
"Renewal of the Control Panel Heat Exchanger Catalog" Introducing the ENH series heat exchangers for control panels that are useful for heat dissipation and dust prevention!
The ENH series heat exchangers for control panels perform heat exchange due to the temperature difference between the inside and outside of the panel, allowing for heat dissipation from the control panel. Unlike heat dissipation fans, using the control panel in a sealed state enables heat dissipation while keeping it dustproof, providing a more reliable heat management solution. At Apiste, we offer two types of heat exchangers: heat pipe type and plate type. The heat pipe type achieves ultra-high efficiency and miniaturization through "super thermal conductive pipes." The plate type enables efficient heat dissipation with the "next-generation heat dissipation module." The documentation includes more detailed features, specifications, and dimensional drawings, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents Included] ■ Lineup of ENH series heat exchangers for control panels ■ Features of heat pipe type heat exchangers ■ Features of plate type heat exchangers ■ Specifications ■ Dimensional drawings ■ Standard panel cut drawings
Achieving ultra-high efficiency and miniaturization with "super thermal conduction pipes"! Heat pipe type heat exchanger.
- Heat exchanger
"Renewal of the Control Panel Heat Exchanger Catalog" Introducing the ENH series heat exchangers for control panels that are useful for heat dissipation and dust prevention!
The ENH series heat exchangers for control panels perform heat exchange due to the temperature difference between the inside and outside of the panel, allowing for heat dissipation from the control panel. Unlike heat dissipation fans, using the control panel in a sealed state enables heat dissipation while keeping it dustproof, providing a more reliable heat management solution. At Apiste, we offer two types of heat exchangers: heat pipe type and plate type. The heat pipe type achieves ultra-high efficiency and miniaturization through "super thermal conductive pipes." The plate type enables efficient heat dissipation with the "next-generation heat dissipation module." The documentation includes more detailed features, specifications, and dimensional drawings, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents Included] ■ Lineup of ENH series heat exchangers for control panels ■ Features of heat pipe type heat exchangers ■ Features of plate type heat exchangers ■ Specifications ■ Dimensional drawings ■ Standard panel cut drawings
This is an environmentally friendly cooler that uses a Peltier element for cooling!
- Cooling system
【Peltier Cooler Catalog Now Available】Introducing environmentally friendly Peltier coolers that do not use refrigerants!
The catalog for the Peltier Cooler NRC series has been renewed. The Apiste Peltier Cooler NRC series uses fully coated special Peltier elements, achieving completely non-Freon clean cooling. It is exempt from the Freon emission control law, eliminating the need for troublesome regular inspections and disposal costs. Additionally, we offer an AC-free power supply type compatible with AC 100V to 240V. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Product Features ■ Specifications ■ Outline Drawing *If you require cooling of 100W or more, a cooler for control panels (non-Freon) is optimal. Please refer to the related products and catalogs below.
Solutions for issues such as 'The temperature of the circulating water isn't rising! It's not dropping!' and 'The circulating water isn't flowing properly!' are provided!
- Chiller
【Data "Chiller Know-How Book Vol. 1" Now Available】Clearly explains solutions to chiller problems such as unstable circulation water temperature and leaks in circulation water!
[We have published the "Chiller Know-How Book Vol. 1"] Are there any users of chillers who are experiencing issues such as "the temperature of the circulating water is unstable," "the circulating water is not flowing properly," or "algae or rust has developed in the circulation path"? This document introduces chillers that can solve such problems and their features. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■CASE01: The temperature of the circulating water won't rise! It won't drop! ■CASE02: The temperature of the circulating water is unstable! ■CASE03: The circulating water is not flowing properly! ■CASE04: Vibration occurs inside the equipment! ■CASE05: Circulating water leaked from the chiller! ■CASE06: Algae or rust has developed in the circulation path!
Solutions for issues such as 'I don't know the flow rate of the circulating water!' and 'I can't log the status of the chiller!' are posted!
- Chiller
[Data "Chiller Know-How Book Vol. 2" Now Available] Clearly explains how to solve chiller problems such as inability to confirm circulation water flow and reduction of circulation water!
[Information: "Chiller Know-How Book Vol.2" has been published] Are there any users of chillers who are facing issues such as "not knowing the flow rate of the circulating water," "the circulating water not returning," or "being unable to log the status of the chiller"? This document introduces solutions to such concerns. If you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■CASE01: I don't know the flow rate of the circulating water! ■CASE02: The temperature accuracy of the circulating water is not sufficient! ■CASE03: The circulating water has run out! ■CASE04: The circulating water is not returning! ■CASE05: Water has gotten into the electrical circuit! ■CASE06: I can't log the status of the chiller!
Introduction to the application guide featuring temperature control for molds and cooling for welding machines!
- Chiller
Introducing applications such as temperature management in the sheet extrusion process and cooling of mixers and tanks!
- Chiller
High-Performance Chiller Application Guide for the Chemical and Resin Industry Now Available
We have published an application guide for the chemical and resin industry that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the chemical and resin industry using our high-performance chiller, the "PCU-SL Series." We will solve various traditional problems in applications such as temperature management in sheet extrusion processes, coating and lamination processes, and temperature control of molds with the high-performance chiller "PCU-SL Series"! We have presented the information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Temperature management in sheet extrusion processes ■ Temperature management in coating and lamination processes ■ Cooling of the water tank for extruders ■ Temperature control of molds ■ Cooling of stirrers and tanks
Introducing applications such as cooling for X-ray inspection equipment!
- Chiller
Publication of the 'High-Performance Chiller Application Guide' for the steel and non-ferrous metal industry.
We have published an application guide for the steel and non-ferrous metal industries that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the steel and non-ferrous metal industries using our high-performance chiller, the "PCU-SL Series." We will solve various conventional problems in applications such as cooling X-ray inspection equipment, plasma seam welding machines, and temperature management for laser processing machines with the high-performance chiller "PCU-SL Series"! We have presented this information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling of X-ray inspection equipment ■ Temperature management of laser processing machines ■ Cooling of plasma seam welding machines ■ Cooling of rolls/bearings/hydraulic units ■ Cooling of high-frequency induction heating devices
Introducing applications for the development and evaluation department of engine bench testers, including cooling systems!
- Chiller
Materials for the Development and Evaluation Department 'High-Performance Chiller Application Guide' Now Available
We have published an application guide for the development and evaluation department that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the development and evaluation department using our high-performance chiller, the "PCU-SL Series." We will solve various conventional problems in applications such as cooling for engine bench testers, battery charge and discharge devices, and utilities for environmental testing rooms and air handling units with the high-performance chiller "PCU-SL Series"! We have presented the information in an easy-to-understand manner, including illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling for engine bench testers ■ Cooling for battery charge and discharge devices ■ Cooling for turbine and motor benches ■ Cooling for radiators and heat exchangers ■ Utilities for environmental testing rooms and air handling units
For cooling mixers and tanks, as well as for cooling laminators, heat sealers, and blisters!
- Chiller
Publication of the document 'High-Performance Chiller Application Guide' for the Food and Pharmaceutical Industry
We have published an application guide for the food and pharmaceutical industries that leverages the features of our high-performance chiller, the "PCU-SL Series." This document introduces applications for the food and pharmaceutical industries using our high-performance chiller, the "PCU-SL Series." We will solve various conventional problems in applications such as cooling for vacuum drying, distillation, sterilization, degassing/defoaming equipment, as well as cooling for mixers and tanks, using the high-performance chiller "PCU-SL Series"! We have presented this information clearly with illustrations, so if you are interested, please download the PDF from the related catalog below or feel free to contact us. [Contents] ■ Cooling for vacuum drying, distillation, sterilization, degassing/defoaming equipment ■ Cooling for mixers and tanks ■ Cooling for thawing equipment transmitters ■ Cooling for laminators, heat sealers, and blisters ■ Cooling for grinders and kneaders
A comprehensive lineup of "chillers" that meets all needs!
- Chiller
[New Chiller Catalog Now Available] Introducing the Apiste Chiller lineup!
Introducing our comprehensive lineup of chillers that meet all your needs! ■ Non-Freon Chiller PCU-NE Series - Uses non-Freon refrigerant R1234yf, exempt from the Freon emission suppression law - Industry-first drive recorder and time calendar function ■ Wide Range Chiller PCU-R Series - Wide range of -10 to 80℃ - Class-leading accuracy of ±0.05℃ ■ High Durability Chiller PCU-SL Series - Does not stop even in high-temperature environments - Usable outdoors
The GDE series dust collectors do not require filter replacement for a long time and can operate in an energy-saving mode, reducing maintenance and running costs.
- Dust collector
Long-term filter replacement is unnecessary, reducing maintenance costs. The Apiste dust collector GDE series allows you to quickly understand operating conditions.
- Dust collector
Long-term filter replacement-free × Easily understand operating conditions - Apiste's dust collector GDE series
- Dust collector