List of Gas recovery/treatment equipment products
- classification:Gas recovery/treatment equipment
361~390 item / All 556 items
Reduce the workload from handling heavy objects! Here are five case studies that solved customer challenges! We are also accepting free consultations and tests tailored to your work!
- Other conveying machines
Presentation of explanatory materials on JIS and ISO standards. We propose suitable safety barriers from a rich product series! Free rental of demo kits.
- Other safety and hygiene products
Removal of HCI gas from an inlet concentration of 100 ppm to an outlet concentration of less than 10 ppm! Introducing a case study of an acidic gas absorption tower.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
The processing gas volume is 50m³/min! A case study of a hydrochloric acid gas absorption tower that removes the outlet concentration to below 2 ppm.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
The processing gas volume is 100 Nm3! We present a case study of an environmental device designed to remove carbon particles!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Acetic acid gas is reduced from 25,000 ppm to below 1 ppm, and fume-like sublimates are removed from 5 g/Nm³ to below 0.1 g/Nm³!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
The processing gas volume is 4568 Nm3/h! The gas-liquid contact is achieved with water (circulation + supply) for cooling and hydrogen removal!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Delivery case of a mist eliminator with a design removal rate of over 99% for particles larger than 20μm and a processing gas volume of 290m³/min.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
The processing gas volume is 1160 m³/min, and the salt recovery concentration is 200–260 g/L. Removal is done using brine (circulation + replenishment)!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
After gas removal, combine to eliminate methanol and formaldehyde! Introducing examples of absorption device deliveries.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Maximum processing gas volume: 35m³/min! A case study of a hydrochloric acid gas absorption tower that removes outlet concentration to below 5 ppm.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Removal of inlet concentration of 10 vol% to an outlet concentration of 0.5 vol% or lower! Introducing a case study of a chlorine gas absorption tower.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Filling height is 3m + with distributor! Case of SO2 dispersion tower with a discharge liquid flow rate of 7.5m3/h.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
The filling height is 3.7m! Introducing a case of an environmental device delivered for the removal of propylene oxide!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Designed to operate within the water supply! Removes inlet hydrochloric acid concentration of 114,444 ppm to an outlet concentration of below 2,289 ppm!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Processing gas volume 70 Nm³/h x 2 series! The coarse removal rate before the filter is designed for an 80% removal efficiency!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Gas concentration is 9300 ppm! Case study of an isopropyl alcohol removal tower with a design removal rate of 80-90%.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Remove to below 40ppm from 715,000ppm! React and convert EG and PG with dilute sulfuric acid solution.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Design removal rate of 90% or more for particles larger than 20μm! We will introduce examples of salt dust removal towers.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Treating exhaust gas from the zinc dissolution tank! Gas temperature is at room temperature with a design removal rate of over 95% for particles larger than φ20μm!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Absorption using caustic soda aqueous solution! Introducing a case study of a hydrogen sulfide removal system with a design removal rate of 99%.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
98% sulfuric acid concentration at the entrance and 60% at the exit! Absorbing and removing moisture from chlorine gas with concentrated sulfuric acid!
- others
- Other environmental equipment
- Gas recovery/treatment equipment
The absorption by water is Max 90°C! We will introduce a case where the outlet concentration of hydrochloric acid gas was below 5 ppm.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
The outlet concentration should be below 2ppm for cyanide gas! We will introduce examples of the delivery of high-concentration chlorine gas and cyanide gas removal towers.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Removal rate of over 90%! We will introduce a case study of an environmental device designed to remove rubber micro-dust.
- others
- Other environmental equipment
- Gas recovery/treatment equipment
Mixing the air in the laboratory with the gas from the source! A compact high-temperature, high-concentration ammonia removal device has been unitized and delivered!
- Gas recovery/treatment equipment
- others
- Other environmental equipment
Recovery of hydrochloric acid in propylene gas as a 20% aqueous solution! Case study of hydrochloric acid recovery and removal equipment delivery.
- Gas recovery/treatment equipment
- others
- Other environmental equipment
Removal rate of over 90% of the design value! Case study of removal target gases such as methyl acrylate and toluene.
- Gas recovery/treatment equipment
- others
- Other environmental equipment
The blower is shared with the denitrification system! When switching to sulfuric acid pickling, remove sulfuric acid mist from 100 mg/m3 to below 5 mg/Nm3.
- Gas recovery/treatment equipment
- others
- Other environmental equipment
To shorten the fermentation time, we promote the activity of fermentation microorganisms (aerobic thermophilic bacteria) through heating, allowing for rapid fermentation within a day.
- Gas recovery/treatment equipment
Introducing a groundbreaking injection molding quality improvement item with an exhaust cross-sectional area 100 times that of conventional gas grooves!
- Ventilation and Exhaust
- Gas recovery/treatment equipment
- Other molds