Would you like to review and improve your equipment? Industrial electric heaters.
An example of solving a problem by changing the insulation material used for the heater's backup!
As a manufacturer of industrial electric heaters, we would like to present some improvement proposals that we can assist with. 【Issues】 "I want to prevent heat loss from the second and third layers of insulation." "I want to achieve energy-saving operation by preventing heat loss." "I want to make the furnace shell space more compact." 【Solutions】 Change the insulation material used as a backup for the heater. Use high-performance insulation material for the second layer. 【Results】 By adopting high-performance insulation material, a reduction in the amount of dissipated heat from the furnace is expected. *With the same thickness setting as calcium silicate board at 5mm, the radiated heat amount is reduced by approximately 50%. ~According to board manufacturer catalog values~
- Company:貞徳舎
- Price:Other