We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Reporting device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Reporting device Product List and Ranking from 16 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

Reporting device Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. NKE Kyoto//Industrial Electrical Equipment
  2. アドコン Shimane//Other manufacturing
  3. アツミ電氣 本社 Shizuoka//others
  4. 4 ヒーロー ヒーローネット Shimane//Consumer Electronics
  5. 5 セキュリティハウス Okayama//Consumer Electronics

Reporting device Product ranking

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

  1. WhiteLock21MM (reporting device equipped with LTE communication module) アドコン
  2. Automatic Email Notification Device "Renra-kun" NKE
  3. Emergency Reporting Device AMT2200 アツミ電氣 本社
  4. 4 Email Reporting Device SCE-86N セキュリティハウス
  5. 5 Emergency Notification Device Emerlink ERS100 アツミ電氣 本社

Reporting device Product List

16~30 item / All 33 items

Displayed results

Simple Email Reporting Device (General Purpose) "Renra-kun"

It is a general-purpose simple email notification device compatible with DHCP.

Renra-kun is a simple information communication terminal that notifies you of minor changes in equipment and environment via email. If you have an internet connection, you can easily set up an email reporting system by simply connecting it to your existing LAN. The settings can be configured using a computer browser, so no dedicated application is required. This allows for a smoother setup process. Additionally, it supports DHCP, further expanding its usability. 【Features】 ○ Simple information communication terminal ○ Supports automatic IP address configuration with "DHCP" ○ No cumbersome IP settings required For more details, please contact us or download the catalog.

  • Other security and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

WhiteLock21MM (reporting device equipped with LTE communication module)

It is a reporting device equipped with an LTE (4G) communication module.

The LTE (4G) communication module is built-in, allowing for remote monitoring in environments without a general line. It is possible to use NTT Docomo's LTE (4G) wireless for "voice reporting" and "SMS email reporting," with a maximum of six settings for each.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

WhiteLock110A20 (4-point remote monitoring for telephone lines)

This is a standard product for a voice reporting device that uses a regular line (telephone line).

Remote monitoring is possible using a standard line (telephone line). There are 4 input signals, and depending on the environment of the reporting destination, both "voice reporting" and "text message reporting" are available. Additionally, you can select the input signals to monitor for each reporting destination. ~ Please check the details in the catalog first!! ~

  • Power Monitoring Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Emergency Reporting Device AMT2200

It detects abnormal signals from various connected sensors and notifies abnormalities through sensor lights and external outputs. A reliable low-cost system.

● Supports up to 64 sensor inputs and can accommodate wireless devices through the installation of a wireless module, enabling cost reduction and shorter construction times. ● Polling function is standard on the AMT2200. ● Improved wiring capability for polling sensors and reduced power consumption enhance adaptability to various sites. ● Allows selection of the optimal reporting method according to the environment of the security location, such as mobile settings. ● Standard support for IP communication enables cost-effective proposals. ● Adoption of main and sub reporting methods establishes a robust reporting system. ● Two types of alert modes (Alert/Home) can be selected. Operations for the alert mode can be performed for each tenant, allowing control for up to 10 tenants and 5 shared areas. ● The entry/exit timer function allows the use of the sensor's alarm delay timer when performing alert/disarm operations within the alert area. ● History data can be saved up to a maximum of 1000 entries.

  • Other security

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

In-house PHS-compatible FA automatic reporting device "SX100"

Would you like to effectively utilize on-site PHS for factory equipment monitoring?

This is a standard model of a notification device that uses an internal PHS (Personal Handy-phone System) for internal communication in factories and hospitals to notify equipment abnormalities via short message. It connects directly to a PLC (Programmable Logic Controller) and easily sends short messages in conjunction with internal relays (ON/OFF). It can build a large-capacity notification system with 250 input points and 10 recipients across 10 groups. There is no need for an email server or internal LAN, and it operates solely on internal communication, making it suitable for high-security factories related to semiconductors and automobiles. ■ Main Features - Internal PHS terminals can be used not only for calls but also for alarm email notifications. - Confirmation can be obtained that the notification has reached the PHS terminal. - High-speed notification with a delay time of about 7 seconds. - No email server is required due to the direct mail delivery method. - It continues to operate from where it left off during power outages and resumes notifications when power is restored. - Custom-made options are available, such as increasing input points and linking with production management servers. - It performs self-diagnosis notifications, including the connected PLC.

  • PBX/IP phone
  • Other FA equipment
  • Email/Fax transmission

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

On-site PHS-compatible hybrid automatic reporting device "SVX100"

It is a message server that integrates PHS short messages and phone voice.

This is a notification device that uses the internal PHS (Personal Handy-phone System) for internal telephones utilized in factories and hospitals to inform about equipment abnormalities via short messages and voice calls. By incorporating two types of transmission ports, it enables applications such as: - Sending PHS short message notifications during regular hours and voice notifications to security personnel's mobile phones at night. - If the abnormal flag is not cleared after the short message notification is completed, a voice reminder notification will be sent. It can build a large-capacity notification system with a standard input of 250 points and 10 recipients per group across 10 groups. Notification groups can choose between short messages and voice calls. The SVX series is particularly known for its high level of customization. ■ Main Features - Internal PHS terminals can be used not only for calls but also for alarm message notifications. - Confirmation can be obtained that the message has been delivered to the PHS terminal. - No email server is required due to the direct mail and direct phone methods. - It operates without failure during power outages and resumes from the point of waiting for notifications when power is restored. - It supports customizations such as increasing input points and redundancy systems. - The voice call port can also be used as a waiting port for push-button commands.

  • PBX/IP phone
  • Other FA equipment
  • Email/Fax transmission

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Emergency Reporting Device Multi-Reporting Machine ADS-100

In case of emergency, automatically report to the registered destination by "signals from various sensors," "pressing the report button," and "lifting the receiver"!

This device connects to a telephone line and automatically makes reports or hotline connections. ● You can choose from three usage modes: "Absent Mode," "Emergency Mode," and "Hotline Mode" by switching the operation mode. - Absent Mode: It automatically dials the reporting destination and sends a reporting message upon receiving an activation signal from the sensor. - Emergency Mode: It automatically dials the reporting destination and sends a reporting message when the "report button" on the main unit is pressed or when it receives an activation signal from the sensor. - Hotline Mode: When the receiver of the connected telephone is lifted, it automatically dials the reporting destination, allowing for a call after sending an announcement message. ● Up to three reporting destinations can be registered. ● In "Absent Mode" and "Emergency Mode," it is possible to monitor indoor sounds or amplify sound from the reporting destination. ● The power supply can be selected from three types: AC power, DC power, or dry batteries.

  • Other PCs and OA equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Automatic Reporting Device E-mail Reporting Device WhiteLock110A17

[Made in Japan] A dedicated reporting device for email using telephone lines. It can be used for equipment monitoring and security surveillance.

You can send emails using the telephone line. A maximum of 30 email notifications can be registered. *Registration is required (monthly fee/paid 500 yen and up).

  • Other security
  • Other security

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Automatic reporting device emergency reporting device WhiteLock110A20

This is an automatic reporting device that connects to general lines and PBX lines. It is equipped with 4 contact inputs for power failure reporting and power restoration reporting functions.

This device incorporates external contacts and automatically reports to mobile phones, telephones, and general telephones. It can also report power outages and restorations. 【Features】 ■ Can connect to general telephone lines and PBX lines. It can be used in conjunction with other telephones, fax machines, and monitoring devices. ■ Various sensors and devices can be connected to four contact inputs. ■ Capable of voice reporting to a maximum of six locations. ■ Can be mounted on a control panel. *For more details, please refer to the PDF document or feel free to contact us.

  • Other security

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Emergency Earthquake Alert Dedicated Notification Device 'SignalNow'

We will notify you before an earthquake based on information provided by the Meteorological Agency.

"SignalNow" is a dedicated reporting device for "advanced users" that offers three reporting functions linked to the Japan Meteorological Agency's emergency earthquake alerts. By utilizing the emergency earthquake alerts, our product informs you of the magnitude of seismic shaking at your specified location using the calculation methods established by the Japan Meteorological Agency. Please feel free to contact us if you have any requests. 【Implementation Effects】 ■ Ensuring the safety of human life ■ Crisis management and disaster prevention measures ■ BCP (Business Continuity Planning) *For more details, please download the PDF or feel free to contact us.

  • Other information systems
  • Other safety equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Security Automatic Reporting Device SC-810X

Automatic reporting of abnormal inputs up to 10 locations by 8 o'clock. Device settings can also be easily configured using the setup tool.

■ Connect to a standard telephone line You can connect to the NTT standard telephone line currently in use, so there is no need to establish a new telephone line. * ISDN lines cannot be used. (In some cases, it may be possible to use them with a TA (Terminal Adapter).) * IP telephone lines cannot be used. (In some cases, it may be possible to use them with an analog port that allows connection of analog telephones, such as a VoIP adapter.) ■ Report up to 8 abnormal inputs It monitors and reports up to 8 abnormalities per sensor or loop. Additionally, you can select the reporting destination for each input. ■ Up to 10 reporting destinations can be registered You can register up to 10 reporting destinations with simple key operations. You can also select between a telephone or mobile phone (voice report) and a computer (data report) for each reporting destination. ■ Reporting with custom voice is possible In addition to fixed messages, you can freely record and confirm original messages.

  • Other security and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Emergency Notification Device SC-25T

It is an emergency reporting device that can use three different modes depending on the purpose.

■Features ● In the event of an emergency, it can send a notification with a custom message of up to 35 seconds to up to three external locations. ● Direct hands-free conversation is possible with the notification destination or an external phone. ● Three modes can be used according to the application: Emergency Mode: Sends a notification when the activation input is triggered or the emergency button is pressed. Absent Mode: Sends a notification after waiting for 30 seconds following the activation input. Hotline Mode: Dials when the handset of the connected phone is lifted. ● If the notification state is activated while on a call with the connected phone, the call will be forcibly terminated.

  • Other security and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Email Reporting Device SCE-86N

We will report the signal anomaly at 8 o'clock via email to mobile phones, computers, etc.

■Features ● Up to 8 signals can be received, and for each input, a maximum of 6 types of notification emails can be registered. (There is no limit on the number of recipients.) ● The existing internet connection environment can be used as is. ● By sending command emails from mobile phones, it is possible to control the monitoring ON/OFF, check the current status, and control remote outputs. ● Its compact design, which takes up little space, makes it ideal for integration into existing alarm panels.

  • Other security and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Multifunctional Emergency Notification Device HEC-610

One-touch emergency call! It is a multifunction type that can also connect with various sensors.

■Easy operation with large buttons ■Adopted large push buttons that are easy to operate for the elderly. ■Up to 10 emergency contacts can be registered ■During an emergency call, it will redial up to 9 times to a maximum of 10 registered contacts. (One answered call will end the emergency notification.) ■Optional message addition is possible ■During an emergency call, it will notify with a 'custom (voice recording up to 15 seconds) + fixed (about 6 seconds, selectable from 16 types)' message. ■System expansion is possible with 6 input contacts and 2 control outputs ■It has 6 input contacts for activating the emergency call, one powered output for LED indicators, and one voltage-free contact output that can also be used for remote control. ■A talkable wireless push button (optional) is available ■You can use up to 8 optional subunits 'talkable wireless push button [TPC-30]'. (Radio range approximately 20m in line of sight) ■Register 3 frequently dialed numbers to one-touch buttons By pressing the one-touch button on the main unit, it will automatically dial without lifting the receiver, allowing for hands-free conversation directed towards the main unit.

  • Other security and surveillance systems

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration