We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 67 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:May 13, 2026~Jun 09, 2026
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:May 13, 2026~Jun 09, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. 東ソー バイオサイエンス事業部 計測分野 Tokyo//Chemical
  3. 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement
  4. 4 サーモフィッシャーサイエンティフィック株式会社/Thermo Fisher Scientific K.K. Tokyo//Testing, Analysis and Measurement
  5. 5 Restek Tokyo//Testing, Analysis and Measurement

column Product ranking

Last Updated: Aggregation Period:May 13, 2026~Jun 09, 2026
This ranking is based on the number of page views on our site.

  1. Innovative solid-phase extraction column Oasis PRiME HLB 日本ウォーターズ(米国本社 Waters Corporation) 
  2. ACQUITY UPLC column 日本ウォーターズ(米国本社 Waters Corporation) 
  3. Shim-pack Series Catalog
  4. 4 Resolute Manual Chromatography Column Sartorius Stedim Japan K.K.
  5. 5 HPLC Column "GPC Column - Molecular Weight Marker" 東ソー バイオサイエンス事業部 計測分野

column Product List

511~540 item / All 640 items

Displayed results

Column "DB-FastFAME"

Corresponds to the requirements of AOAC, AOCS, and IOC regulatory methods! Chemical bonding, crosslinking type, solvent washable.

"DB-FastFAME" is a cyano-propyl phase designed for the high-speed and selective separation of both saturated and unsaturated fatty acid methyl esters (FAME). It also accommodates the separation of challenging cis-trans FAME isomers without compromising the separation capability obtained with conventional 100m columns. In less than 8 minutes, it can separate conventional FAMEs, including C18:1 and C18:2 cis/trans isomers, as well as common FAMEs such as DPA and EPA found in dairy fat, vegetable oils, and fish oils. 【Features】 ■ A cyano-propyl phase (G48) designed for the high-speed and selective separation of FAME ■ Ensures reproducibility of FAME equivalent chain length (ECL) values through individual testing with FAME mixtures ■ Complies with the requirements of AOAC, AOCS, and IOC regulatory methods ■ Chemically bonded, cross-linked type, solvent-washable ■ Intuvo specifications are also available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-88"

Maximum temperature 250/260℃! Designed for the separation of fatty acid methyl esters (FAME).

We would like to introduce the column "HP-88" that we handle. It is designed for the separation of fatty acid methyl esters (FAME) and is highly polar. It excels in the separation of cis/trans isomers compared to "DB-23" and is designed to withstand even higher temperatures while having nearly the same selectivity as "CP-Sil 88." 【Features】 ■ (88%-cyanopropyl) methylallyl polysiloxane ■ Upper limit temperature 250/260℃ ■ High polarity ■ Designed for the separation of cis/trans fatty acid methyl esters (FAMEs) ■ Even better separation of cis-trans isomers than "DB-23" *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Particle Trap Integrated PLOT PT Column

Analysis using GCMS and Capillary Flow Technology (CFT) is possible!

The "Particle Trap Integrated PLOT PT Column" is designed to enhance laboratory analysis work. There is no need to install a separate particle trap, allowing for leak-free analysis to be performed easily and reliably. The integrated particle trap technology is incorporated into the column as a single continuous fused silica tube. 【Features】 ■ Enables analysis using GCMS and Capillary Flow Technology (CFT), which have been difficult with PLOT columns until now. ■ No unions or traps are required for connecting a separate particle trap. ■ The integrated particle trap technology is incorporated into the column as a single continuous fused silica tube. *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraBOND U"

Expand the maximum operating temperature! Improve data accuracy and detection limit with a low bleed type.

"PoraBOND U" is a chemical bond-type PLOT column that uses a high-polarity polymer as an adsorbent. The maximum operating temperature has been expanded from 190°C to 300°C. By keeping the bleed level low, the detection limit can be lowered, and the stabilization time of the column can also be shortened. Additionally, because it is a chemical bond-type column, it can be applied to analytical methods that require pressure changes. 【Features】 ■ Expanded maximum operating temperature ■ Low bleed type improves data accuracy and detection limits ■ Chemical bond type for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT Q"

The reproducibility of retention time is stable! Water elutes at a sharp peak, improving quantification accuracy.

"PoraPLOT Q" is a column suitable for the analysis of a wide range of volatile compounds. This product can elute water with a sharp peak. It is capable of analyzing not only high-polarity volatile compounds but also non-polar hydrocarbons and permanent gases. Please feel free to consult us when you need assistance. 【Features】 ■ Applicable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Elutes water with a sharp peak, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT S"

Good reproducibility! Volatile compounds from high polarity to non-polar eluted with symmetrical peaks.

"PoraPLOT S" is a column for the analysis of hydrocarbons and ketones. It uses divinylbenzene-vinylpyridine as an adsorbent. It is suitable for the analysis of moderately polar volatile compounds that require higher temperatures than the maximum usage temperature. Please feel free to consult us when you need assistance. 【Features】 ■ Elution of volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimization of particle shedding ■ Good reproducibility *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 KCl"

Recommended for many ASTM methods! Suitable for KCI deactivated alumina.

The "HP-PLOT Al2O3 KCl" is a column that can separate gases at room temperature. It is suitable for the analysis of low molecular weight hydrocarbon isomers from C1 to C8. It has been treated with different inertization methods on Al2O3, providing good resolution in hydrocarbon isomer analysis. Please feel free to consult us when you need assistance. 【Features】 ■ Low polarity alumina phase ■ Inertized with KCl ■ Recommended for many ASTM methods ■ Suitable for alumina treated with KCl inertization ■ Lower retention of olefins compared to corresponding paraffins *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Al2O3/KCl"

High separation ability for hydrocarbons! Expands the scope of analysis with two polarities.

The "CP-Al2O3/KCl" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offers high separation capability, and allows for analysis in a shorter time. Compared to capillary columns using a liquid phase, it has higher selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands the range of analysis with two polarities *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Al2O3/Na2SO4"

High separation ability for hydrocarbons! A metal column that is resistant to physical shock.

The "CP-Al2O3/Na2SO4" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offering high separation capability and allowing for analysis in a shorter time. Compared to capillary columns using liquid phases, this product has high selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands analysis range with two polarities ■ Metal column resistant to physical shocks *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 M"

Inactivated with KCl! Suitable for the analysis of lower hydrocarbons of C1 to C8 hydrocarbon isomers.

The "HP-PLOT Al2O3 M" is a column that can separate gases at room temperature. It is suitable for accurate quantitative analysis of dienes, particularly for separating propadiene and butadiene from the flow of ethylene and propylene. It has undergone different inertization treatments on Al2O3, providing good resolution in hydrocarbon isomer analysis. 【Features】 ■ Inertized with KCl ■ Low polarity alumina phase ■ Suitable for KCl inertized alumina ■ Recommended for many ASTM methods ■ Standard column suitable for low hydrocarbon analysis of C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-CarbonPLOT"

High stability, combined carbon layer stationary phase! Unique selectivity for inorganic and organic gases.

The "GS-CarbonPLOT" is a column with high stability and a bonded carbon layer stationary phase. The temperature limit has been extended to 360°C. It has retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ High stability, bonded carbon layer stationary phase ■ Unique selectivity for inorganic and organic gases ■ Temperature limit extended to 360°C ■ Suitable for GC/MS - does not generate particles ■ Retention stability that is not affected by water *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CarboPLOT P7"

Analyzing carbon monoxide at ppmR levels! Stability and robustness to enhance the reproducibility of results.

The "CarboPLOT P7" is a column compliant with ASTM D 2505. It is suitable for the analysis of samples containing oxygen or air. It can separate nitrogen and carbon monoxide, demonstrating excellent performance for quantifying carbon monoxide at the ppm level. 【Features】 ■ Column compliant with ASTM D 2505 ■ Stability and robustness that enhance result reproducibility ■ Fast separation of carbon monoxide and carbon dioxide ■ Separation of oxygen and nitrogen ■ Analysis of carbon monoxide at the ppm level *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

LC column for PFC analysis

Very high stability and long lifespan at a pump pressure of up to 1200 bar! To be used mounted on the pump.

The "PFC Analysis LC Column" is designed and tested to efficiently delay the elution of per/polyfluoroalkyl compounds (PFCs or PFAS) released from pump components, solvent lines, and solvents. When these compounds co-elute, they can interfere with the detection of PFCs in samples such as drinking water, potentially affecting quantitative results. This product is recommended for use in conjunction with the InfinityLab PFC-Free LC Conversion Kit (5004-0006). It is not an analytical column. 【Features】 - Delays the elution of PFC compounds released from pumps, solvent lines, and solvents - Designed with particles and dimensions that allow for maximum retention while reducing column backpressure - Included in the InfinityLab PFC-Free LC Conversion Kit (5004-0006) *For more details, please refer to the related links or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

LC column for biopharmaceutical analysis 'Oligonucleotide standard sample'

Separation efficiency standard sample for testing N/N-1 separation efficiency! Comes with an analysis certificate.

The "Oligonucleotide Standard Sample" is a bio-pharmaceutical analysis LC column that is freeze-dried in high-recovery glass auto-sampler vials and shipped with an analysis certificate. It contains synthetic nucleotides of 14, 17, 20, and 21 mer, designed to test N/N-1 separation capability. The "Oligonucleotide Ladder Standard Sample" includes synthetic oligodeoxythymidines of 15, 20, 25, 30, 35, and 40 mer. By using this standard sample, you can test the selectivity and reproducibility of the column. 【Features】 ■ Separation standard sample for testing N/N-1 separation capability ■ Ladder standard sample for selectivity and reproducibility testing ■ Freeze-dried in high-recovery glass auto-sampler vials ■ Comes with an analysis certificate *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "AdvanceBio Peptide Plus"

Excellent in speed, sensitivity, and efficiency! Quickly confirm and identify target proteins and peptides.

"AdvanceBio Peptide Plus" is a reverse-phase surface porous particle LC column optimized for the separation of target peptides, impurities, and post-translational modifications. By modifying 2.7μm particles with a C18 stationary phase treated with a hybrid end-capping process and a pore size of 100Å, a charged surface is formed. Using this product, multiple critical quality attributes can be reliably identified using LC/MS. [Features] ■ Achieves high separation efficiency with the particle morphology of Poroshell, maintaining performance even at high load amounts. ■ Excellent performance is achieved even when using mobile phases containing formic acid, thanks to the hybrid C-18 and chemically modified silica that provide surface charge. ■ It is also possible to use standard C18 columns to improve the separation and resolution of important components. *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "AdvanceBio Amino Acid Analysis (AAA)"

Designed as an innovative solution for the characterization of biomolecules!

The "AdvanceBio Amino Acid Analysis (AAA)" is an LC column for biopharmaceutical analysis that can separate amino acids from protein hydrolysates and cell culture media with high speed, excellent sensitivity, and reproducibility. It includes proven reagents for amino acid derivatization, a prepared amino acid standard kit, columns based on our innovative Poroshell technology, and support from our experts. When used in conjunction with Agilent InfinityLab LC series instruments, it provides a complete solution for amino acid analysis. 【Features】 ■ Achieves high separation capability with the efficient particle morphology of Poroshell ■ Long column life due to robust chemically modified silica with excellent resistance to high pH ■ Utilizes 2.7μm diameter particles, compatible with both HPLC and UHPLC systems ■ Standard solutions and reagents available as a kit ■ Uses a general analysis injection system *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-WAX Ultra Inert"

Highly active and analytically challenging compounds, minimizing adsorption and decomposition! Achieving consistent inertness.

The "DB-WAX Ultra Inert" column provides symmetrical peak shapes and demonstrates better results for challenging polar compounds by using a highly inert polyethylene glycol. Individually tested with the Ultra Inert WAX test mixture based on QC specifications, it minimizes adsorption and decomposition for highly active, difficult-to-analyze compounds such as free fatty acids, alcohols, diols, and aldehydes, achieving consistent inertness. Additionally, it has the same selectivity as DB-WAX, allowing for easy column upgrades without the need to recreate existing compound libraries. 【Features】 ■ Improved peak shapes for challenging polar compounds ■ High inertness ■ Selectivity equivalent to DB-WAX: no need to revalidate methods ■ Equivalent to USP G16 ■ Excellent performance for acidic compounds including free fatty acids ■ Solvent-cleanable *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Multiple Affinity Removal Column - Human7

Remove seven types of excess protein with a simple method.

The "Multiple Affinity Removal Column Human7" is an LC column designed for biopharmaceutical analysis that removes seven types of proteins, including abundant albumin, from human plasma samples, making it easier to separate and identify low-concentration proteins in human serum. By removing high-concentration proteins, the dynamic range of analysis can be effectively expanded. It can enhance the performance of LC/MS and electrophoresis analysis of serum samples. 【Features】 ■ Removes approximately 88-92% of total protein ■ Available in three column sizes: ・4.6 x 50mm ・4.6 x 100mm ・10 x 100mm ■ Custom-made column sizes are also available *For more details, please refer to the related links or feel free to contact us.

  • Other consumables
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Plgel PlusPore

Demonstrates the highest level of resolution within a narrow molecular weight range.

The "PLgel GPC column" demonstrates the highest level of resolution within a narrow molecular weight range. By connecting columns, the applicable molecular weight range can be expanded. Single pore columns are suitable for measuring very small polymers or very large polymers that are usually difficult to dissolve with the more common PLgel MIXED columns. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PL Rapide

Providing high speed and high resolution with an older system.

The "PL Rapide GPC Column" combines high-efficiency PLgel media with wide-bore hardware to provide high speed and high resolution for older systems. By increasing the flow rate and reducing analysis time, it enhances overall resolution in high dead volume systems and large flow cell detectors. *For more details, please refer to the PDF materials or feel free to contact us.*

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

MonoSpin ME column for purification and concentration of trace samples

Simple and fast processing of trace samples by centrifugation.

MonoSpin is a spin column for sample preparation using silica monoliths with uniform continuous pores. Through centrifugation, it effectively facilitates the preparation of trace samples such as biological specimens. MonoSpin ME is a column that is bonded with iminodiacetic acid groups, making it ideal for the recovery of trace metals in samples. Features: ● Simple operation through centrifugation ● High-speed processing enabled by a structure with high permeability ● Excellent reproducibility even with elution volumes of less than 100 µL

  • Other experimental consumables
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Pipette tip type His-tagged protein purification PhyTip column

Comprehensive HTS from His tag purification in small amounts! IMAC PhyTip column

The IMAC PhyTip column allows for easy affinity purification in small amounts, starting from a minimum resin volume of 5 µL. If you want to process recombinant protein purification in small quantities with multiple samples, it can be handled using HTS. It is compatible with major liquid handlers for chip-type chromatography. The use of the PhyTip column requires slow pipetting operations, so a dedicated electric pipetter, such as the 'ME System', or a liquid handler robot is necessary. It supports a wide variety of resins and custom packing is also available.

  • Separation device
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

HPLC column "Ion Chromatography"

Explanation of separation and analysis using anion analysis columns, illustrated with diagrams.

This document explains ion chromatography of HPLC columns. It provides an explanation of the separation and analysis of both anion analysis columns and cation analysis columns, using diagrams and tables. 【Contents (excerpt)】 ■ Anion analysis column (for IC-2010) ■ Cation analysis column (for IC-2010) ■ Anion analysis column (non-suppressor type) ■ Anion analysis eluent ■ Cation analysis column (non-suppressor type) *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

HPLC column "Size Exclusion Chromatography"

Features of the SEC column and a list of compatibility with H-type solvents are included.

This document explains size exclusion chromatography (SEC) for HPLC columns. It includes features of SEC columns and a list of compatible H-type solvents. Additionally, the section on SEC column selection provides a detailed explanation of both aqueous SEC column selection (for synthetic polymers) and organic solvent-based SEC column selection, using tables for clarity. 【Contents (excerpt)】 ■ Features of SEC columns ■ List of compatible H-type solvents ■ SEC column selection ■ Aqueous SEC columns (for proteins, peptides, and nucleic acids) ■ Aqueous SEC columns (for synthetic polymers, polysaccharides, oligosaccharides, and nucleic acids) *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

RPC system column 'TSKgel Protein C4-300'

The recovery rate of general water-soluble proteins is high, and the peak shape is excellent.

"TSKgel Protein C4-300" is a reverse phase chromatography column for the separation of biomacromolecules, using a packing material with silica gel of particle size 3μm and pore size 30nm, with butyl groups (C4) immobilized. It exhibits strong protein retention and excellent separation selectivity. 【Features】 ■ Strong protein retention and excellent separation selectivity ■ High recovery rate for general water-soluble proteins, with superior peak shape ■ Due to the use of fine particle packing material (3μm), it enables high throughput, high separation, and high sensitivity measurements ■ The 2mm inner diameter column is suitable for LC/MS (/MS) measurements *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

SEC column "TSKgel UP-SW3000"

Due to the microparticle filler, rapid analysis of biomacromolecules such as proteins, antibodies, and enzymes is possible.

The latest column is the UP-SW3000-LS. Please refer to that as well. The "TSKgel UP-SW3000" is a size exclusion chromatography column for the separation of biomacromolecules, using a packing material that chemically bonds diol groups to the surface of silica gel particles with a diameter of 2μm. Due to the fine particle packing material, rapid analysis (15cm column) and high-resolution analysis (30cm) of biomacromolecules such as proteins, antibodies, and enzymes are possible. 【Features】 ■ Enables rapid analysis (15cm column) and high-resolution analysis (30cm) ■ Surface characteristics of the packing material are similar to existing TSKgel SW types ■ Optimized for the separation of antibody (IgG) dimers, monomers, and fragments ■ Compatible with both UHPLC and HPLC systems *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

SEC column "TSKgel UP-SW2000"

Due to the microparticle filler (2 μm), rapid analysis of biomacromolecules and mid-sized molecules such as low molecular weight proteins, peptides, and oligonucleotides is possible.

● The surface properties of the packing material are similar to the existing TSKgel SW type. ● It is suitable for the separation of low molecular weight proteins, fragments, peptides, and oligonucleotides. 【Features】 ■ Rapid analysis (15 cm column) and high-resolution analysis (30 cm) are possible. ■ The surface properties of the packing material are similar to the existing TSKgel SW type. ■ Optimized for the separation of antibody (IgG) dimers, monomers, and fragments. ■ Compatible with both UHPLC and HPLC systems. *For more details, please refer to the PDF document or feel free to contact us.*

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Tosoh's SEC columns for biomacromolecules "UP-SW Series"

The "UP-SW Series" SEC columns for biomacromolecules from Tosoh, known for their proven performance and reliability. These are high-resolution SEC columns with minimal non-specific adsorption.

Optimized microparticle fillers (2µm, 3µm) enable rapid analysis (15cm column) and high-resolution analysis (30cm) of biomacromolecules such as proteins, antibodies, and enzymes. The surface characteristics of the fillers are similar to those of the widely used general-purpose SWXL series columns. They are compatible with both UHPLC and HPLC systems.

  • UPSWシリーズ.png
  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Technical Information: About TSKgel SuperIC-WA

Explanation of columns specialized for ion chromatography focused on tap water analysis! This is a column for simultaneous analysis of anions and bromate!

This document is a technical material explaining the TSKgel SuperIC-WA column for high-performance ion chromatography. It introduces the basic properties of the packing material and column, separation characteristics, and application examples. [Contents (excerpt)] ■ Introduction ■ Product specifications list ■ Basic properties ■ Application examples - Analysis of tap water - Analysis of bromate and chlorate in sodium hypochlorite ■ Conclusion *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration