We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column Product List and Ranking from 17 Manufacturers, Suppliers and Companies | IPROS GMS

Last Updated: Aggregation Period:Feb 11, 2026~Mar 10, 2026
This ranking is based on the number of page views on our site.

column Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Feb 11, 2026~Mar 10, 2026
This ranking is based on the number of page views on our site.

  1. アジレント・テクノロジー株式会社 Tokyo//Testing, Analysis and Measurement
  2. Restek Tokyo//Testing, Analysis and Measurement
  3. 日本ウォーターズ(米国本社 Waters Corporation)  Tokyo//Testing, Analysis and Measurement
  4. 4 山善 Osaka//Machine elements and parts
  5. 5 null/null

column Product ranking

Last Updated: Aggregation Period:Feb 11, 2026~Mar 10, 2026
This ranking is based on the number of page views on our site.

  1. GC column "SE-30/SE-54" アジレント・テクノロジー株式会社
  2. Low-adsorption LC column MaxPeak Premier column 日本ウォーターズ(米国本社 Waters Corporation) 
  3. GC column "DB-624" アジレント・テクノロジー株式会社
  4. 4 RMX GC column using TriMax deactivation technology Restek
  5. 5 Column "Inject Column" 山善

column Product List

121~150 item / All 192 items

Displayed results

Column "DB-5.625"

Wide-ranging support for the analysis of basic, neutral, and acidic compounds! Cleaning with solvents is also possible.

The "DB-5.625" is a non-polar column of the chemical bonding type, enhanced in inertness and sensitivity through special processing. It is suitable as a standard column for the analysis of semi-volatile compounds using EPA methods 625, 1625, 8270, and CLP protocols. It features excellent thermal stability, a high temperature limit, and low bleed. Special testing has ensured performance that exceeds EPA performance standards for semi-volatile compounds. 【Features】 ■ Performance comparable to (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Performance exceeding EPA performance standards for semi-volatile compounds ■ Inert to basic, neutral, and acidic compounds ■ Excellent thermal stability, allowing for a high temperature limit and low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-5ms Semi-Volatile"

Demonstrates industry-leading sensitivity and consistency in the effective temperature range of -60 to 325/350℃!

The "HP-5ms Semi-Volatile" is a column that has been confirmed through testing to be inert to highly active compounds such as acidic and basic compounds. It demonstrates industry-leading sensitivity and consistency within an effective temperature range of -60 to 325/350°C. Testing is conducted based on Agilent's strict QC industry standards, and it features a chemical bond and cross-linking type, allowing for cleaning with solvents. 【Features】 ■ Has the same selectivity as HP-5 (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Ultra-low bleed suitable for GC/MS ■ Inertness to active compounds such as acidic and basic compounds confirmed through testing ■ Improved sensitivity and mass spectrum integrity due to excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 5/C18 CB for PCB"

Designed for high-resolution analysis of PCBs! It has a C18 substituent and lower polarity than 100% polydimethylsiloxane.

The "CP-Sil 5/C18 CB for PCB" is a column with a C18 substituent that has lower polarity than 100% polydimethylsiloxane. Due to the absence of a cyano group, it allows for ECD detection with a high S/N ratio. With a 100m column, it can separate important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190. 【Features】 ■ Designed for high-resolution analysis of PCBs ■ Has a C18 substituent and lower polarity than 100% polydimethylsiloxane ■ Allows for ECD detection with a high S/N ratio ■ Offers suitable column lengths for the separation of important isomer pairs 28/31, 56/60, 149/118, 105/153/132, and 170/190 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-Dioxin"

Separation of 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis!

"DB-Dioxin" is a column designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF). It is capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis. A 100 psi regulator is required to achieve the appropriate carrier gas flow rate. 【Features】 ■ Designed for the analysis of polychlorinated dibenzo-p-dioxins (PCDD) and polychlorinated dibenzofurans (PCDF) ■ Capable of separating 2,3,7,8-TCDD and 2,3,7,8-TCDF from all other isomers in a single analysis ■ Low bleed ■ Chemical bonding and cross-linking type ■ Washable with solvent *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select PAH"

Completely separate all PAH isomers! Provide accurate analysis results without false positives.

"Select PAH" is a capillary column that serves as a single solution for the analysis of polycyclic aromatic hydrocarbons (PAH). With excellent resolution for PAH isomers, it allows for the rapid, easy, and accurate quantification of PAHs in environmental and food samples. Since all isomers are separated in a single run, reliable analysis results without false positives can be obtained. 【Features】 ■ Completely separates all PAH isomers, providing accurate analysis results without false positives ■ Fully separates EPA-designated PAHs, including chrysene, triphenylene, and benzo(a)fluoranthene, in under 7 minutes, and EU-regulated PAHs in under 30 minutes ■ Provides rapid results in a single analysis ■ High sensitivity due to low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-EUPAH"

Designed for the analysis of PAHs regulated by the EU! Appropriate column dimensions to achieve reliable performance.

The "DB-EUPAH" column is optimized to achieve maximum performance in the analysis of all 16 types of polycyclic aromatic hydrocarbons (PAHs) regulated by the EU. Testing with application-specific QC test mixtures is conducted on all columns. It has very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene. 【Features】 ■ Designed for the analysis of EU-regulated PAHs ■ Testing with application-specific QC test mixtures is conducted on all columns ■ Excellent resolution for important isomers such as benzo(b,j,k)fluoranthene ■ Very high thermal stability, allowing for accurate analysis of high-boiling PAHs such as dibenzopyrene ■ Excellent S/N ratio *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select 624 CB"

Excellent column-to-column reproducibility! Highly reliable qualitative/quantitative results can be obtained.

The "CP-Select 624 CB" is a column that further enhances the reproducibility of the proven 624 stationary phase. Bleed is kept to 1/2 to 1/3 of that of typical columns (for a column with a length of 30m, an inner diameter of 0.53mm, and a film thickness of 3.00μm, the bleed specification is 9pA). With 6% cyanopropylphenyl and 94% dimethylpolysiloxane as the stationary phase, maximum inter-column reproducibility is ensured through rigorous synthesis based on strict standards and thorough characterization. 【Features】 ■ Reliable and precise separation of EPA-designated volatile compounds according to EPA methods 524.2, 624, and 8015. ■ Designated column for the pharmacopoeial method V.3.3.9 for residual solvent analysis, ensuring compliance. ■ Excellent inter-column reproducibility. ■ Low bleed. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select 624 Hexane"

Since it undergoes testing based on QC specifications, highly reliable qualitative/quantitative results can be obtained!

The "CP-Select 624 Hexane" is a column designed for the separation of hexane isomers and dichloromethane, offering excellent reproducibility. Specialized QC tests for applications ensure appropriate resolution and inter-column reproducibility. Please feel free to contact us when you need assistance. 【Features】 ■ A stationary phase equivalent to USP G43 optimized for the separation of hexane isomers and dichloromethane ■ Separates acetonitrile and dichloromethane with a specified resolution of ≧1.0 according to USP <467> Residual Solvents ■ Excellent inter-column reproducibility ■ Undergoes testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results ■ Ensures the resolution of the CP-Select 624 Hexane column for separating dichloromethane from hexane isomers through application-specific QC tests *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-VOC"

Cleaning with solvent is possible, excellent peak shape! Highly reliable qualitative/quantitative results can be obtained!

The "HP-VOC" is a column precisely designed to exhibit excellent performance in the analysis of volatile organic compounds. The effective temperature range is -60 to 280/290°C, optimized for EPA Methods 502.2, 524.2, and 8260. This chemical bond/cross-linked type column provides high-quality peak shapes and can be used for applications requiring the analysis of purgeable or volatile organic compounds, volatile aromatic hydrocarbons, and unsaturated hydrocarbons. 【Features】 ■ Optimized selectivity for U.S. EPA Methods 502.2, 524.2, and 8260 ■ Low polarity ■ Excellent peak shape ■ Chemical bond/cross-linked type ■ Washable with solvent ■ Subjected to testing based on very stringent industry QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-502.2"

Wide temperature range! We also offer a 105m column suitable for the analysis of volatile compounds.

The DB-502.2 is a column that achieves excellent peak shape in analyses based on EPA Method 502.2. It features a chemical bond and crosslinking type, and can be cleaned with solvents. Rigorous testing based on extremely strict industry QC standards ensures that highly accurate and consistent analytical results can be obtained. Additionally, a wide operating temperature range of 0 to 260/280°C is one of the characteristics of this precisely designed product. 【Features】 - A 105m column is also available for the analysis of volatile compounds - Excellent peak shape - Chemical bond and crosslinking type - Can be cleaned with solvents - Due to testing based on the industry's very stringent QC specifications regarding column bleed, sensitivity, and efficiency, highly reliable qualitative and quantitative results can be achieved. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-MTBE"

Since it undergoes testing based on QC specifications, highly reliable qualitative/quantitative results can be obtained!

The "DB-MTBE" we handle is a column with a low-polarity stationary phase. It is of the chemical bonding and crosslinking type, allowing for cleaning with solvents. This product undergoes extensive testing based on extremely strict industry QC standards and is precisely designed to enable purge and trap injection without low-temperature concentration. It can separate MTBE from 2-methylpentane and 3-methylpentane, demonstrating excellent resolution over a temperature range of 35 to 260/280°C. 【Features】 ■ Low-polarity stationary phase ■ Separates MTBE from 2-methylpentane and 3-methylpentane, improving the reliability of quantitative results ■ Purge and trap injection possible without low-temperature concentration ■ Chemical bonding and crosslinking type ■ Cleaning with solvents is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Select CB for MTBE"

Highly reliable qualitative/quantitative results can be obtained! Unique selectivity allows for easy analysis of MTBE!

Our column "CP-Select CB for MTBE" ensures highly reproducible results in the analysis of MTBE in reformulated gasoline. It features a wide dynamic range suitable for the quantification of MTBE, maximizing productivity for increasingly demanding volatile compound applications. It is ideal as a primary analysis column or as a complementary confirmation column. 【Features】 ■ Designed for the analysis of MTBE in reformulated gasoline ■ Unique selectivity for MTBE ■ Wide dynamic range suitable for the quantification of MTBE ■ Suitable as a primary column or confirmation column ■ Subjected to testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-TPH"

Temperature range of -10 to 320°C! Introducing high-speed analysis columns with chemical bonding and cross-linking types!

The column "DB-TPH" handled by our company is designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and the analysis of leaks (LUFT) from underground fuel tanks. It can perform three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection. It allows for solvent cleaning and is compatible with a temperature range of -10 to 320°C. Additionally, high quality is ensured through extensive QC testing, demonstrating excellent performance in petroleum analysis applications. 【Features】 ■ Designed for the analysis of total petroleum hydrocarbons (TPH), soil analysis, and LUFT analysis ■ Capable of performing three analyses (gasoline range organic compounds, diesel range organic compounds, motor oil) in a single injection ■ High-speed analysis ■ Chemical bonding and cross-linking type ■ Solvent cleaning is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-FastFAME"

Corresponds to the requirements of AOAC, AOCS, and IOC regulatory methods! Chemical bonding, crosslinking type, solvent washable.

"DB-FastFAME" is a cyano-propyl phase designed for the high-speed and selective separation of both saturated and unsaturated fatty acid methyl esters (FAME). It also accommodates the separation of challenging cis-trans FAME isomers without compromising the separation capability obtained with conventional 100m columns. In less than 8 minutes, it can separate conventional FAMEs, including C18:1 and C18:2 cis/trans isomers, as well as common FAMEs such as DPA and EPA found in dairy fat, vegetable oils, and fish oils. 【Features】 ■ A cyano-propyl phase (G48) designed for the high-speed and selective separation of FAME ■ Ensures reproducibility of FAME equivalent chain length (ECL) values through individual testing with FAME mixtures ■ Complies with the requirements of AOAC, AOCS, and IOC regulatory methods ■ Chemically bonded, cross-linked type, solvent-washable ■ Intuvo specifications are also available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-88"

Maximum temperature 250/260℃! Designed for the separation of fatty acid methyl esters (FAME).

We would like to introduce the column "HP-88" that we handle. It is designed for the separation of fatty acid methyl esters (FAME) and is highly polar. It excels in the separation of cis/trans isomers compared to "DB-23" and is designed to withstand even higher temperatures while having nearly the same selectivity as "CP-Sil 88." 【Features】 ■ (88%-cyanopropyl) methylallyl polysiloxane ■ Upper limit temperature 250/260℃ ■ High polarity ■ Designed for the separation of cis/trans fatty acid methyl esters (FAMEs) ■ Even better separation of cis-trans isomers than "DB-23" *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraBOND U"

Expand the maximum operating temperature! Improve data accuracy and detection limit with a low bleed type.

"PoraBOND U" is a chemical bond-type PLOT column that uses a high-polarity polymer as an adsorbent. The maximum operating temperature has been expanded from 190°C to 300°C. By keeping the bleed level low, the detection limit can be lowered, and the stabilization time of the column can also be shortened. Additionally, because it is a chemical bond-type column, it can be applied to analytical methods that require pressure changes. 【Features】 ■ Expanded maximum operating temperature ■ Low bleed type improves data accuracy and detection limits ■ Chemical bond type for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT Q"

The reproducibility of retention time is stable! Water elutes at a sharp peak, improving quantification accuracy.

"PoraPLOT Q" is a column suitable for the analysis of a wide range of volatile compounds. This product can elute water with a sharp peak. It is capable of analyzing not only high-polarity volatile compounds but also non-polar hydrocarbons and permanent gases. Please feel free to consult us when you need assistance. 【Features】 ■ Applicable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Elutes water with a sharp peak, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT S"

Good reproducibility! Volatile compounds from high polarity to non-polar eluted with symmetrical peaks.

"PoraPLOT S" is a column for the analysis of hydrocarbons and ketones. It uses divinylbenzene-vinylpyridine as an adsorbent. It is suitable for the analysis of moderately polar volatile compounds that require higher temperatures than the maximum usage temperature. Please feel free to consult us when you need assistance. 【Features】 ■ Elution of volatile compounds from high polarity to non-polar with symmetrical peaks ■ Minimization of particle shedding ■ Good reproducibility *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 KCl"

Recommended for many ASTM methods! Suitable for KCI deactivated alumina.

The "HP-PLOT Al2O3 KCl" is a column that can separate gases at room temperature. It is suitable for the analysis of low molecular weight hydrocarbon isomers from C1 to C8. It has been treated with different inertization methods on Al2O3, providing good resolution in hydrocarbon isomer analysis. Please feel free to consult us when you need assistance. 【Features】 ■ Low polarity alumina phase ■ Inertized with KCl ■ Recommended for many ASTM methods ■ Suitable for alumina treated with KCl inertization ■ Lower retention of olefins compared to corresponding paraffins *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Al2O3/KCl"

High separation ability for hydrocarbons! Expands the scope of analysis with two polarities.

The "CP-Al2O3/KCl" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offers high separation capability, and allows for analysis in a shorter time. Compared to capillary columns using a liquid phase, it has higher selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands the range of analysis with two polarities *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Al2O3/Na2SO4"

High separation ability for hydrocarbons! A metal column that is resistant to physical shock.

The "CP-Al2O3/Na2SO4" is a column for the analysis of C1 to C5 hydrocarbons and impurities. It can analyze more compounds at once than packed columns, offering high separation capability and allowing for analysis in a shorter time. Compared to capillary columns using liquid phases, this product has high selectivity and can separate C1 to C5 hydrocarbon isomers. 【Features】 ■ High separation capability for hydrocarbons ■ Short analysis time for hydrocarbons at temperatures above room temperature ■ Expands analysis range with two polarities ■ Metal column resistant to physical shocks *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Al2O3 M"

Inactivated with KCl! Suitable for the analysis of lower hydrocarbons of C1 to C8 hydrocarbon isomers.

The "HP-PLOT Al2O3 M" is a column that can separate gases at room temperature. It is suitable for accurate quantitative analysis of dienes, particularly for separating propadiene and butadiene from the flow of ethylene and propylene. It has undergone different inertization treatments on Al2O3, providing good resolution in hydrocarbon isomer analysis. 【Features】 ■ Inertized with KCl ■ Low polarity alumina phase ■ Suitable for KCl inertized alumina ■ Recommended for many ASTM methods ■ Standard column suitable for low hydrocarbon analysis of C1 to C8 hydrocarbon isomers *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "GS-CarbonPLOT"

High stability, combined carbon layer stationary phase! Unique selectivity for inorganic and organic gases.

The "GS-CarbonPLOT" is a column with high stability and a bonded carbon layer stationary phase. The temperature limit has been extended to 360°C. It has retention stability that is not affected by water. Agilent's commitment to reliability and reproducibility in its products supports the improvement of quality levels demanded by chromatography experts. Please feel free to consult us when needed. 【Features】 ■ High stability, bonded carbon layer stationary phase ■ Unique selectivity for inorganic and organic gases ■ Temperature limit extended to 360°C ■ Suitable for GC/MS - does not generate particles ■ Retention stability that is not affected by water *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CarboPLOT P7"

Analyzing carbon monoxide at ppmR levels! Stability and robustness to enhance the reproducibility of results.

The "CarboPLOT P7" is a column compliant with ASTM D 2505. It is suitable for the analysis of samples containing oxygen or air. It can separate nitrogen and carbon monoxide, demonstrating excellent performance for quantifying carbon monoxide at the ppm level. 【Features】 ■ Column compliant with ASTM D 2505 ■ Stability and robustness that enhance result reproducibility ■ Fast separation of carbon monoxide and carbon dioxide ■ Separation of oxygen and nitrogen ■ Analysis of carbon monoxide at the ppm level *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "AdvanceBio Peptide Plus"

Excellent in speed, sensitivity, and efficiency! Quickly confirm and identify target proteins and peptides.

"AdvanceBio Peptide Plus" is a reverse-phase surface porous particle LC column optimized for the separation of target peptides, impurities, and post-translational modifications. By modifying 2.7μm particles with a C18 stationary phase treated with a hybrid end-capping process and a pore size of 100Å, a charged surface is formed. Using this product, multiple critical quality attributes can be reliably identified using LC/MS. [Features] ■ Achieves high separation efficiency with the particle morphology of Poroshell, maintaining performance even at high load amounts. ■ Excellent performance is achieved even when using mobile phases containing formic acid, thanks to the hybrid C-18 and chemically modified silica that provide surface charge. ■ It is also possible to use standard C18 columns to improve the separation and resolution of important components. *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "AdvanceBio Amino Acid Analysis (AAA)"

Designed as an innovative solution for the characterization of biomolecules!

The "AdvanceBio Amino Acid Analysis (AAA)" is an LC column for biopharmaceutical analysis that can separate amino acids from protein hydrolysates and cell culture media with high speed, excellent sensitivity, and reproducibility. It includes proven reagents for amino acid derivatization, a prepared amino acid standard kit, columns based on our innovative Poroshell technology, and support from our experts. When used in conjunction with Agilent InfinityLab LC series instruments, it provides a complete solution for amino acid analysis. 【Features】 ■ Achieves high separation capability with the efficient particle morphology of Poroshell ■ Long column life due to robust chemically modified silica with excellent resistance to high pH ■ Utilizes 2.7μm diameter particles, compatible with both HPLC and UHPLC systems ■ Standard solutions and reagents available as a kit ■ Uses a general analysis injection system *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-WAX Ultra Inert"

Highly active and analytically challenging compounds, minimizing adsorption and decomposition! Achieving consistent inertness.

The "DB-WAX Ultra Inert" column provides symmetrical peak shapes and demonstrates better results for challenging polar compounds by using a highly inert polyethylene glycol. Individually tested with the Ultra Inert WAX test mixture based on QC specifications, it minimizes adsorption and decomposition for highly active, difficult-to-analyze compounds such as free fatty acids, alcohols, diols, and aldehydes, achieving consistent inertness. Additionally, it has the same selectivity as DB-WAX, allowing for easy column upgrades without the need to recreate existing compound libraries. 【Features】 ■ Improved peak shapes for challenging polar compounds ■ High inertness ■ Selectivity equivalent to DB-WAX: no need to revalidate methods ■ Equivalent to USP G16 ■ Excellent performance for acidic compounds including free fatty acids ■ Solvent-cleanable *For more details, please refer to the PDF document or feel free to contact us.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

PL Rapide

Providing high speed and high resolution with an older system.

The "PL Rapide GPC Column" combines high-efficiency PLgel media with wide-bore hardware to provide high speed and high resolution for older systems. By increasing the flow rate and reducing analysis time, it enhances overall resolution in high dead volume systems and large flow cell detectors. *For more details, please refer to the PDF materials or feel free to contact us.*

  • Analytical Equipment and Devices
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "FlexFire C8"

For the separation of methods and improvement of peak shapes! We provide retention and separation, not time savings.

The "FlexFire C8" is a column developed primarily based on hydrophobic interactions, just like the FlexFire C18. Traditionally, the short alkyl chain provided advantages in time reduction, but it offers retention and separation instead of time savings. It is useful for improving the separation and peak shape of established methods. 【Features】 ■ Developed primarily based on hydrophobic interactions, like the FlexFire C18 ■ Provides retention and separation instead of time savings ■ Useful for improving the separation and peak shape of established methods ■ Despite having a carbon content of 12%, its bonding density is almost the same as that of C18 ■ Utilizes refined silica gel *For more details, please refer to the PDF document or feel free to contact us.

  • Other protein analysis
  • Column Chromatography
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "FlexFire HILIC"

Building methods with organic solvent composition rich! Improved detection sensitivity in LC/MS is expected.

"FlexFire HILIC" simply utilizes silica gel as the base material to achieve the retention and separation of highly polar compounds. By adding a 1.6μm particle size, which was not previously available in the lineup, it enables time savings and solvent reduction through ultra-fast analysis. Additionally, analysis in normal phase mode using non-aqueous solvents is possible, allowing for behaviors not seen in reverse phase columns. [Features] ■ Improved retention and separation of highly polar compounds ■ Expected enhancement in detection sensitivity in LC/MS ■ Time savings and solvent reduction through ultra-fast analysis ■ Analysis in normal phase mode using non-aqueous solvents is also possible ■ Utilizes refined silica gel *For more details, please refer to the PDF document or feel free to contact us.

  • Other protein analysis
  • Column Chromatography
  • column

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration