We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column×アジレント・テクノロジー株式会社 - List of Manufacturers, Suppliers, Companies and Products

column Product List

91~105 item / All 157 items

Displayed results

GC column "DB-5"

Low breed! We introduce a non-polar column with a wide range of applications at high upper temperature limits!

The "DB-5" is a non-polar column made of (5% phenyl) methyl siloxane. It features a chemical bond and crosslinking type, and is capable of solvent washing. It corresponds to USP Phase G27, and we offer a wide variety of column sizes. Please feel free to contact us when you need assistance. 【Features】 ■ (5%-phenyl)-methyl polysiloxane ■ Non-polar ■ Excellent general-purpose column ■ Wide range of applications ■ Low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-5"

Chemical bonding and cross-linking type, with a wide range of applications! We introduce an excellent general-purpose column!

The "HP-5" is a non-polar column made of (5%-phenyl)-methylpolysiloxane. It corresponds to USP Phase G27 and can be solvent cleaned at high upper temperature. We continue to pursue further improvements in analytical performance standards such as separation efficiency, reproducibility of retention times, and peak height ratios. Please feel free to contact us when you need assistance. 【Features】 ■ (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Excellent general-purpose column ■ Wide range of applications ■ High upper temperature *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 8 CB"

It shows excellent selectivity for aromatic compounds and is a suitable column for condition testing!

The 'CP-Sil 8 CB', which uses 5% phenyl and 95% dimethyl polysiloxane as the liquid phase, is a column with slightly higher polarity than the 'CP-Sil 5 CB'. It demonstrates excellent selectivity for aromatic compounds and is suitable for condition testing. Additionally, it shows good inter-column reproducibility, high separation efficiency, and selectivity. 【Features】 ■ Uses 5% phenyl and 95% dimethyl polysiloxane as the liquid phase ■ High-efficiency and high-precision GC column ■ Offers various column sizes ■ Improves productivity with excellent reproducibility and selectivity *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-35"

Pursuing further improvement in analysis performance standards such as separation efficiency and peak height ratio!

We would like to introduce the GC column "DB-35" that we handle. It has a slightly higher polarity than medium polarity (HP-35) and low bleed. It is inert to active solutes and suitable for confirmation analysis. It is a chemically bonded and cross-linked type, allowing for solvent washing. 【Features】 ■ (35%-phenyl) methyl polysiloxane ■ Slightly higher polarity than medium polarity (HP-35) ■ Low bleed ■ Inert to active solutes ■ Suitable for confirmation analysis *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC Column "HP-35"

Methyl siloxane column with substituted phenyl groups! Suitable for EPA Method 8081.

We would like to introduce the GC column "HP-35" that we handle. This is a methyl siloxane column with phenyl groups substituted. This column is suitable for EPA Method 8081 and is equivalent to USP G-42. Additionally, due to its medium polarity, it is suitable for the analysis of pesticides, herbicides, pharmaceuticals, and amines. 【Features】 ■ (35%-phenyl) methyl polysiloxane ■ Slightly lower polarity than medium polarity (DB-35) ■ Inactive towards active solutes ■ Suitable for confirmatory analysis ■ Chemically bonded and cross-linked type *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-200"

Suitable for separating difficult-to-separate positional isomers! Introducing a medium-polarity column of methyl polysiloxane.

We would like to introduce our product, the "DB-200." It is a medium-polarity column made of (35% trifluoropropyl) methylpolysiloxane. It has a higher polarity than the medium-polarity "DB-1701" and "DB-17," and exhibits unique interactions with compounds containing nitro groups, halogen groups, and carbonyl groups. 【Features】 ■ (35% trifluoropropyl) methylpolysiloxane ■ Temperature limit 300/320℃ ■ Higher polarity than medium-polarity "DB-1701" and "DB-17" ■ Suitable for difficult-to-separate positional isomers ■ Exhibits unique interactions with compounds containing nitro groups, halogen groups, and carbonyl groups *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-210"

Suitable for U.S. EPA Methods 8140 and 609! Chemical bonding/crosslinking type, solvent cleaning possible.

We would like to introduce our GC column "DB-210." It is equivalent to (50% trifluoropropyl) methyl polysiloxane and has high polarity. It is suitable for U.S. EPA Methods 8140 and 609 and is a chemically bonded and cross-linked type. It allows for solvent cleaning and serves as a replacement for HP-210. 【Features】 ■ (50% trifluoropropyl) methyl polysiloxane ■ High polarity ■ Suitable for U.S. EPA Methods 8140 and 609 ■ Chemically bonded and cross-linked type ■ Solvent cleaning possible ■ Replacement for HP-210 ■ Equivalent to USP Phase G6 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-1301"

Pursuing further improvement of performance standards! Alternatives to HP-1301/HP-1701.

We would like to introduce our GC column "DB-1301." It is a (6% cyanopropylphenyl) methylpolysiloxane, equivalent to USP Phase G43. It has low to medium polarity and is of the chemical bond/crosslink type. It serves as a substitute for HP-1301/HP-1701. 【Features】 ■ (6% cyanopropylphenyl) methylpolysiloxane ■ Equivalent to USP Phase G43 ■ Low to medium polarity ■ Chemical bond/crosslink type ■ Substitute for HP-1301/HP-1701 ■ Solvent-cleanable *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "SE-30/SE-54"

Highly reliable qualitative/quantitative results can be obtained! Operating temperature range is 0 to 325/350℃.

The "SE-30" is a 100% dimethyl polysiloxane column, while the "SE-54" is a (5%-phenyl) (1%-vinyl)-methyl polysiloxane column. Both columns are precisely designed to ensure a temperature operating range of 0 to 325/350°C, providing high accuracy, efficiency, and reproducibility of results. These columns can be used in established methods that require columns without cross-linked or chemically bonded polymer phases, as they are neither chemically bonded nor cross-linked. 【Features】 ■ Operating temperature range of 0 to 325/350°C ■ Precisely designed to ensure high accuracy, efficiency, and reproducibility of results ■ Neither chemically bonded nor cross-linked ■ Can be used in established methods that require columns without cross-linked or chemically bonded polymer phases *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column 'DB-WAXetr'

Excellent reproducibility between columns! Introducing solvent-washable chemical bond and crosslink type columns.

The "DB-WAXetr" is a column with a wide temperature range and high polarity. It is a chemically bonded and cross-linked type, and can be cleaned with solvents. It corresponds to USP Phase G16. Our commitment to the reliability and reproducibility of our products supports the improvement of quality levels demanded by chromatography professionals. 【Features】 ■ Polyethylene glycol (PEG) ■ Wide temperature range (etr: Extend Temperature Range) ■ High polarity ■ Excellent reproducibility between columns ■ Chemically bonded and cross-linked type ■ Can be cleaned with solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-INNOWax"

Excellent reproducibility of inter-column inertness! Solvent cleaning possible with chemical bonding and cross-linking type.

"HP-INNOWax" is a polyethylene glycol (PEG) stationary phase characterized by high polarity and a high temperature limit. It corresponds to the USP (United States Pharmacopeia) G16 liquid phase and is intended for applications such as food, fragrances, and perfumes. The improved Agilent J&W HP-INNOWax GC column series utilizes an innovative inert treatment also employed in the manufacturing of Agilent J&W DB-Wax ultra-inert columns. These columns maintain excellent inertness over the long term, even after repeated temperature cycling up to the column's upper temperature limit. 【Features】 ■ High polarity ■ PEG bonded phase with the highest temperature limit ■ Achieves sharp, symmetrical peak shapes for highly active polar compounds ■ Excellent reproducibility of inter-column inertness ■ Solvent-washable with chemical bonding and cross-linking type ■ Corresponds to USP G16 liquid phase *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-FFAP"

Chemical bonding and crosslinking type, solvent cleaning is possible! Free fatty acids can be analyzed up to C24.

The "HP-FFAP" is a column that allows for the injection of organic acids without derivatization by modifying polyethylene glycol polymer with acid. It can analyze free fatty acids up to C24 and is designed for the analysis of volatile fatty acids and phenols. It features chemical bonding and cross-linking types, and solvent washing is possible. It corresponds to USP Phase G35. 【Features】 ■ Nitroterephthalic acid modified polyethylene glycol ■ High polarity ■ Temperature range of 60°C to 240/250°C (230/240°C for 0.53mm) ■ Designed for the analysis of volatile fatty acids and phenols ■ Equivalent to OV-351 ■ Corresponds to USP Phase G35 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Wax 57 CB"

Unique selectivity suitable for alcohol analysis in wine and beer! Unique high-polarity wax column.

"CP-Wax 57 CB" is a GC column suitable for alcohol analysis in beverages. It has a unique selectivity that is ideal for alcohol analysis in wine and beer. Due to high passivation treatment, it shows excellent peak shapes even for high-polarity compounds. Particularly, the model with an inner diameter of 0.15mm significantly improves analysis speed. 【Features】 ■ Unique high-polarity wax column ■ Uses chemically bonded 100% polyethylene glycol in the liquid phase ■ Good peak shapes for alcohol and glycol *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-1ht"

Chemical bonding, crosslinking type! Achieves excellent peak shape and rapid elution with high boiling point compounds.

The "DB-1ht" column demonstrates high performance across a wide range of GC/MS applications, designed to achieve high quality and stability. It has been specially treated to operate at temperatures up to 400°C and is equipped with an optimized polyimide-coated fused silica tube. Additionally, using these chemically bonded, cross-linked type columns allows for excellent peak shapes with high boiling point compounds, while also reducing elution times. Cleaning with solvents is also possible. 【Features】 ■ 100% Dimethylpolysiloxane ■ Non-polar ■ Specially treated for a temperature limit of 400°C ■ Fused silica tube with polyimide coating for high temperatures ■ Achieves excellent peak shapes and rapid elution with high boiling point compounds ■ Cleaning with solvents is possible *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-5ht"

Optimize sensitivity and accuracy for the analysis of high molecular weight compounds! Lifespan is extended, and peak shape is improved.

The "DB-5ht" is a column suitable for analyzing high-boiling compounds with low bleed even at high temperatures. It is based on ultra-low bleed technology and demonstrates high selectivity, sensitivity, and accuracy in the analysis of high molecular weight compounds. The temperature range is -60 to 400°C for fused silica and -60 to 450°C for UltiMetal stainless steel. 【Features】 - Improved stability extends column life and reduces downtime. - Enhanced detector performance improves the detection limit. - Maintains ultra-low bleed even at high temperatures, making it ideal for analyzing high-boiling compounds. - Optimizes sensitivity and accuracy for the analysis of high molecular weight compounds. - Same selectivity as VF-5ms (the bleed specification for a 30m×0.25mm column is <5pA at 400°C). *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration