We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Variable Area Flow Meter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Variable Area Flow Meter Product List and Ranking from 4 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

Variable Area Flow Meter Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. null/null
  2. ティ・アイ・シィ計測器工業 Osaka//Machine elements and parts
  3. 大阪フローメーター工業 Osaka//Industrial Machinery 本社
  4. 4 カワキ計測工業 Hyogo//Testing, Analysis and Measurement
  5. 5 null/null

Variable Area Flow Meter Product ranking

Last Updated: Aggregation Period:Jul 16, 2025~Aug 12, 2025
This ranking is based on the number of page views on our site.

  1. Area-type flow meter "NK Series"
  2. Area-type flow meter "Purge Meter LH/EK/A·C·D"
  3. Area-type flow meter "SPT type (vertical simple type)" ティ・アイ・シィ計測器工業
  4. 4 Area-type flow meter "ST model (vertical multipurpose type)" ティ・アイ・シィ計測器工業
  5. 5 Area type flow meter "KS type (vertical type)" ティ・アイ・シィ計測器工業

Variable Area Flow Meter Product List

16~24 item / All 24 items

Displayed results

Area-type flow meter "SPT type (vertical simple type)"

Area flow meter that can be connected with flange mounting or threaded union!

This model is a simplified version of the "ST type (vertical multi-purpose type)" and is a mass-produced instrument specifically prepared for measuring clean water. Due to its shape, it features the capability for both flange mounting and screw union connection (except for SPT-15). 【Specifications (excerpt)】 ■ Application: General clean water measurement ■ Manufacturing diameters: 1/2″, 3/4″, 1″, 2″, etc. ■ Model numbers: SPT-15 to SPT-50 ■ Pressure resistance: Maximum 5 kg/cm² to 10 kg/cm² (static pressure) ■ Maximum usable temperature: 60℃ *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "RL type / RLM type"

The magnet-integrated instrument has a sealed structure. It is a flow meter designed for measuring lateral flow, opaque fluids, and fluids containing slurries.

The "RL type and RLM type" are area-type flow meters designed for use in horizontal piping installations. The "RLM type" features a built-in magnet and a sealed structure designed to prevent liquid leakage at the scale indicator, making it suitable for measuring opaque fluids and slurry-containing fluids. Additionally, this model is robust and versatile, similar to the "UL and ULM types," and allows for various linings in the wetted parts. 【Specifications (excerpt)】 ■ Applications: Measurement of opaque fluids, slurry-containing fluids, etc. (capable of measuring strong acidic, alkaline liquids, organic solvents, etc.) ■ Manufacturing diameter: 3/4″ to 12″ ■ Model numbers: RL-20 to RL-300, RLM-20 to RLM-300 ■ Pressure resistance: Maximum 10 kg/cm² to 50 kg/cm² (static pressure) *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "ULM(diameter)-HF(flange standard) for high temperature"

Heat-resistant structure capable of measuring superheated saturated water and superheated steam, equipped with cooling fins!

This model is an area-type flow meter based on the "ULM type" designed for measuring opaque fluids. It features a heat-resistant structure to enable measurements of superheated saturated water and superheated steam, and is equipped with cooling fins. With a completely sealed structure, it can be used for a wide range of applications from opaque fluids (such as slurry-containing liquids) to gases and steam. 【Specifications (excerpt)】 ■ Applications: Measurement of transparent and opaque fluids and gases (Capable of measuring alkaline, strongly acidic, organic solvents, etc.) ■ Manufacturing diameter: 1/2″ to 12″ ■ Model numbers: ULM-15-HF-(flange standard) to ULM-300-HF-(flange standard) ■ Pressure resistance: Maximum 50kg/cm2G (static pressure) *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meters "ULA type, RLA type"

Guideline display for easy reading of values! It is also possible to add upper and lower limit contact mechanisms and output signals.

The "ULA type / RLA type" is a multipurpose instrument that adopts a pointer display method based on the "UL type / RL type." In addition to the advantage of being able to perform isolation measurements visually, it is also possible to add upper and lower limit contact mechanisms and output signals. It can be used for opaque fluids, slurries, and other similar fluids. 【Specifications (excerpt)】 ■ Applications: For measuring transparent and opaque fluids, gases, etc. ■ Manufacturing diameter: 1″ to 12″ ■ Model numbers: ULA-25 to 300, RLA-25 to 300 ■ Pressure resistance: Up to 30 kg/cm² ■ Maximum allowable temperature: 120℃ *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meters "ULE type, RLE type"

A flow meter that allows control by quantity rather than by pressure or other factors!

The "ULA type and RLA type" are versatile instruments equipped with total counters and pulse output counters, as well as instantaneous indication needles. In addition to indicating the cumulative flow value, when the cumulative flow value reaches a certain number, it emits a pulse, and the counter automatically returns to zero. This cycle can be used for further accumulation, allowing control based on quantity rather than pressure or other factors. 【Specifications (excerpt)】 ■ Applications: For measuring transparent and opaque fluids, gases, etc. ■ Model numbers: ULE-40 to 300, RLE-40 to 300 ■ Pressure resistance: Maximum 30 kg/cm² ■ Maximum operating temperature: 80°C ■ Power supply: AC100V, AC200V, 50Hz or 60Hz *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "SPV type"

Equipped with an adjustable flow needle valve! Introduction of products for measuring purge pipe flow.

The "SPV type" is a small-diameter flow meter designed and manufactured for the purpose of measuring very low flow rates. It is used for flow monitoring and features a needle valve that allows for flow adjustment while reading the position of the float, which is a significant characteristic. 【Specifications (excerpt)】 ■ Application: For monitoring flow in purge pipes, air and other gases, general clean water or liquid measurement ■ Model number: SPV-8 to 15 ■ Manufacturing diameter: 1/4" to 1/2" ■ Pressure resistance: Maximum 10 kg/cm² (static pressure) ■ Usable temperature range: +10 to +60℃ *For more details, please refer to the PDF document or feel free to contact us.

  • Other measurement, recording and measuring instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Area-type flow meter "RPF TYPE Flange Type"

It is an area flow meter that allows you to specify the flow direction.

The "RPF TYPE Flange Type" is an area-type flow meter that allows you to freely determine the flow direction. Unlike other flange types, it can be installed in any direction—front, back, left, or right—according to your specifications. 【Features】 ■ Flow direction can be freely determined ■ Can be installed in any direction—front, back, left, or right—according to specifications *For more details, please refer to the catalog or feel free to contact us.