iPROS Manufacturing
  • Search for products by classification category

    • Electronic Components and Modules
      Electronic Components and Modules
      55896items
    • Machinery Parts
      Machinery Parts
      70742items
    • Manufacturing and processing machinery
      Manufacturing and processing machinery
      95514items
    • Scientific and Physics Equipment
      Scientific and Physics Equipment
      33004items
    • Materials
      Materials
      34865items
    • Measurement and Analysis
      Measurement and Analysis
      52711items
    • Image Processing
      Image Processing
      14547items
    • Control and Electrical Equipment
      Control and Electrical Equipment
      50370items
    • Tools, consumables, and supplies
      Tools, consumables, and supplies
      62939items
    • Design and production support
      Design and production support
      11703items
    • IT/Network
      IT/Network
      40960items
    • Office
      Office
      13068items
    • Business support services
      Business support services
      39948items
    • Seminars and Skill Development
      Seminars and Skill Development
      5817items
    • Pharmaceutical and food related
      Pharmaceutical and food related
      23095items
    • others
      59294items
  • Search for companies by industry

    • Manufacturing and processing contract
      7356
    • others
      5052
    • Industrial Machinery
      4435
    • Machine elements and parts
      3289
    • Other manufacturing
      2871
    • IT/Telecommunications
      2516
    • Trading company/Wholesale
      2454
    • Industrial Electrical Equipment
      2318
    • Building materials, supplies and fixtures
      1821
    • software
      1652
    • Electronic Components and Semiconductors
      1574
    • Resin/Plastic
      1494
    • Service Industry
      1401
    • Testing, Analysis and Measurement
      1132
    • Ferrous/Non-ferrous metals
      979
    • environment
      702
    • Chemical
      631
    • Automobiles and Transportation Equipment
      560
    • Printing Industry
      506
    • Information and Communications
      431
    • Consumer Electronics
      422
    • Energy
      321
    • Rubber products
      311
    • Food Machinery
      305
    • Optical Instruments
      284
    • robot
      270
    • fiber
      250
    • Paper and pulp
      232
    • Electricity, Gas and Water Industry
      173
    • Pharmaceuticals and Biotechnology
      165
    • Warehousing and transport related industries
      144
    • Glass and clay products
      142
    • Food and Beverage
      134
    • CAD/CAM
      121
    • Educational and Research Institutions
      108
    • retail
      106
    • Medical Devices
      99
    • Ceramics
      95
    • wood
      87
    • Transportation
      83
    • Medical and Welfare
      61
    • Petroleum and coal products
      60
    • Shipbuilding and heavy machinery
      53
    • Aviation & Aerospace
      47
    • Fisheries, Agriculture and Forestry
      39
    • self-employed
      23
    • Public interest/special/independent administrative agency
      19
    • equipment
      19
    • Mining
      17
    • Materials
      15
    • Research and development equipment and devices
      14
    • Finance, securities and insurance
      13
    • Government
      13
    • Individual
      10
    • Restaurants and accommodations
      8
    • Police, Fire Department, Self-Defense Forces
      7
    • cosmetics
      7
    • Laboratory Equipment and Consumables
      3
    • Contracted research
      3
    • Raw materials for reagents and chemicals
      2
  • Special Features
  • Ranking

    • Overall Products Ranking
    • Overall Company Ranking
Search for Products
  • Search for products by classification category

  • Electronic Components and Modules
  • Machinery Parts
  • Manufacturing and processing machinery
  • Scientific and Physics Equipment
  • Materials
  • Measurement and Analysis
  • Image Processing
  • Control and Electrical Equipment
  • Tools, consumables, and supplies
  • Design and production support
  • IT/Network
  • Office
  • Business support services
  • Seminars and Skill Development
  • Pharmaceutical and food related
  • others
Search for Companies
  • Search for companies by industry

  • Manufacturing and processing contract
  • others
  • Industrial Machinery
  • Machine elements and parts
  • Other manufacturing
  • IT/Telecommunications
  • Trading company/Wholesale
  • Industrial Electrical Equipment
  • Building materials, supplies and fixtures
  • software
  • Electronic Components and Semiconductors
  • Resin/Plastic
  • Service Industry
  • Testing, Analysis and Measurement
  • Ferrous/Non-ferrous metals
  • environment
  • Chemical
  • Automobiles and Transportation Equipment
  • Printing Industry
  • Information and Communications
  • Consumer Electronics
  • Energy
  • Rubber products
  • Food Machinery
  • Optical Instruments
  • robot
  • fiber
  • Paper and pulp
  • Electricity, Gas and Water Industry
  • Pharmaceuticals and Biotechnology
  • Warehousing and transport related industries
  • Glass and clay products
  • Food and Beverage
  • CAD/CAM
  • Educational and Research Institutions
  • retail
  • Medical Devices
  • Ceramics
  • wood
  • Transportation
  • Medical and Welfare
  • Petroleum and coal products
  • Shipbuilding and heavy machinery
  • Aviation & Aerospace
  • Fisheries, Agriculture and Forestry
  • self-employed
  • Public interest/special/independent administrative agency
  • equipment
  • Mining
  • Materials
  • Research and development equipment and devices
  • Finance, securities and insurance
  • Government
  • Individual
  • Restaurants and accommodations
  • Police, Fire Department, Self-Defense Forces
  • cosmetics
  • Laboratory Equipment and Consumables
  • Contracted research
  • Raw materials for reagents and chemicals
Special Features
Ranking
  • Overall Products Ranking
  • Overall Company Ranking
  • privacy policy
  • terms of service
  • About Us
  • Careers
  • Advertising
  1. Home
  2. others
  3. T.K.K.エボリューション (株式会社エランビタールは2022年4月1日より社名変更しました)
  4. Product/Service List
others
  • Added to bookmarks

    Bookmarks list

    Bookmark has been removed

    Bookmarks list

    You can't add any more bookmarks

    By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

    Free membership registration

T.K.K.エボリューション (株式会社エランビタールは2022年4月1日より社名変更しました)

addressKanagawa/Minami-ku, Yokohama-shi/25-2 Sanchuntai
phone045-231-1686
  • Official site
last updated:Feb 14, 2023
T.K.K.エボリューションlogo
  • Contact this company

    Contact Us Online
  • Before making an inquiry

    Download PDF
  • Company information
  • Products/Services(41)
  • catalog(19)
  • news(51)

T.K.K.エボリューション List of Products and Services

  • category

1~41 item / All 41 items

Displayed results

class="retina-image"

"Use rust to control rust" - Measures to combat the deterioration of water pipes!

With the "Piping Magnetite Method," achieve low cost, short construction time, and a higher level of water environment!

If you install a BW system utilizing the piping magnetite method in your water supply pipe facilities, the water quality will change, and the red rust inside the pipes will begin to transform into black rust. Black rust is a crystalline form that is closer to metal, with a density ten times higher than that of red rust, which improves the blockage rate within the pipes. Additionally, areas where the wall thickness has become thin, nearing leakage, will be repaired by black rust. This method can also be applied to drainage pipes. Please feel free to contact us for on-site surveys or estimates. * We are currently providing a comparison with other methods and case studies in PDF format. * For more details, please download the PDF or contact us. * The section titled 'What sparked your interest?' displayed during the PDF download is generated by Ipros Inc.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

"Control rust with rust" - Measures against water pipe deterioration!

With the "Piping Magnetite Method," achieve low cost, short construction period, and a higher level of water environment!

By installing a BW system utilizing the piping magnetite method in the water supply pipe facilities, the water quality will change, and the red rust inside the pipes will begin to transform into black rust. Black rust is a crystalline form that is closer to metal, with a density ten times higher than that of red rust, which improves the blockage rate inside the pipes, and areas where the wall thickness is thin and on the verge of leaking will be repaired by black rust. Additionally, this method can also be applied to drainage pipes. Please feel free to contact us for on-site surveys or estimates. *We are currently providing comparisons with other methods and case studies in PDF format. *For more details, please download the PDF or contact us. *The section titled 'What sparked your interest' displayed during the PDF download is generated by Ipros Co., Ltd.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water supply pipe red rust countermeasure "Piping Magnetite Method" - NETIS registered!

【Low Budget Black Rusting!】By installing a water conditioning device, the red rust in the pipes is transformed into black rust through water conditioning, restoring the thickness of the degraded pipes!

The "Piping Magnetite Method" is a technique that uses the treated water from the water treatment device "The Bio Water" to convert the red rust in the water supply pipes into black rust (Fe3O4), thereby extending the life of the piping. Through water treatment, the crystals of calcium carbonate coating inside the pipes become denser. As a result, the oxidation of the base metal beneath the coating progresses slowly, reacting with the existing red rust and converting it into black rust (Fe2O3 + Fe0 → Fe3O4). This black rust formation repairs and restores the areas of pitting in the pipes. If we can obtain a sample of the water from the site where the work will be performed, we will conduct a laboratory test to predict the effectiveness (this testing method is patented in Japan, the USA, Europe, Singapore, and Malaysia). Improvements in the blockage rate of the pipes, as well as prevention of leaks and red water occurrence, can be achieved with a low budget and short construction period. Depending on the hardness, it is generally maintenance-free, thus reducing maintenance costs and effort. 【Features】 ◇ Registered with NETIS (KT-160125-VR) ◇ Construction involves simple work at the water supply pipe connection, with a short construction period of about half a day to one day ◇ There is no need to replace pipes, allowing for low-cost red rust countermeasures ◇ The effects are semi-permanent, allowing the water supply pipes to be used for the lifespan of the building ◇ The BOD of the wastewater decreases, reducing the environmental impact on water ◇ The ability to predict effectiveness through laboratory tests ensures peace of mind during construction

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

They are completely different! The difference between "piping magnetite method" and "magnetic device."

A thorough comparison of the advantages, such as the elimination of the "magnetic field control every few years" that comes with magnetic devices, and the long-lasting effects of modified water!

■Construction Method 【Piping Magnetite Method】 Install BWΩ in the piping to modify the water passing through the device, converting red rust to black rust and repairing the deteriorated areas with black rust. 【Magnetic Method】 Install a magnetic device in the piping to increase the potential in areas that prevent iron from rusting. ■Construction 【Piping Magnetite Method】 Install at one location on the main water supply pipe. 【Magnetic Method】 Installation of the device is required every 50 meters. ■Maintenance 【Piping Magnetite Method】 No maintenance required. 【Magnetic Method】 The effectiveness weakens if the direction of the magnetic field is not changed every few years. ■Cost and Construction Period 【Piping Magnetite Method】 Particularly low cost compared to other methods, with a short construction period. 【Magnetic Method】 Lower cost and shorter construction period compared to other methods. ■Sustainability of Modified Water Effects 【Piping Magnetite Method】 Lab tests confirmed effects lasting 4 months, and field tests confirmed effects lasting up to 8 years. 【Magnetic Method】 Effects disappear in about 84 hours. ■Environmental Impact 【Piping Magnetite Method】 Produces good water for domestic use and reduces water environmental impact such as wastewater. 【Magnetic Method】 No impact on the water environment. Additionally, comparisons with piping replacement work and lining methods are available in PDF format. For more details, please refer to the PDF document or feel free to contact us.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water supply pipe rust prevention "Piping Magnetite Method" - NETIS registered!

Low budget black rusting! By installing a water conditioning device, the red rust in the pipes is transformed into black rust, restoring the thickness of the deteriorated pipes!

The "Piping Magnetite Method" uses the modified water from the water modification device "The Bio Water" to convert the red rust in the water supply pipes into black rust (Fe3O4), thereby extending the life of the piping. Through water modification, the crystals of the calcium carbonate coating inside the pipes become denser. As a result, the oxidation of the base metal beneath the coating progresses slowly, reacting with the existing red rust to form black rust (Fe2O3 + Fe0 → Fe3O4). This black rust formation repairs and restores the areas of pitting in the piping. If we can obtain a sample of the water from the construction site, we will conduct a laboratory test to predict the effectiveness (this testing method is patented in Japan, the U.S., Europe, Singapore, and Malaysia). Improvements in the blockage rate of the piping, as well as prevention of leaks and red water occurrence, can be achieved with a low budget and short construction period. Depending on the hardness, it is generally maintenance-free, thus reducing maintenance costs and efforts. 【Features】 ◇ NETIS registered (KT-160125-VR) ◇ The construction involves simple work at the water supply pipe connection, taking about half a day to one day ◇ There is no need to replace pipes, allowing for low-cost red rust countermeasures ◇ The effects are semi-permanent, allowing the water supply pipes to be used for the lifespan of the building ◇ The BOD of the wastewater decreases, reducing the environmental impact on water ◇ Laboratory tests can predict effectiveness, ensuring peace of mind during construction

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Comparison of the Piping Magnetite Method with Other Methods

Comparison with typical water supply pipe deterioration countermeasures! We introduce the duration of effectiveness and issues.

The "Piping Magnetite Method" involves installing BW in the water supply pipes, which slows down the oxidation rate, transforming red rust into black rust and repairing the deteriorated areas. This method can also be applied to leaking pipes and has a semi-permanent effect. The "Piping Replacement Work" is an immediate and fundamental solution since the pipes are new, but it is very costly and generates a large amount of waste. The "Lining Method" damages the pipes, making a second application impossible. The "Magnetic Device Installation" has issues such as being ineffective at low flow rates. In addition, we also provide materials that cover all topics. 【Features of the Piping Magnetite Method】 ■ Low cost and short construction period ■ Effects extend to drainage pipes ■ Improved cleaning power, antioxidant power, and antibacterial power ■ Effect measurement device allows for FS *For more details, please refer to the PDF materials or feel free to contact us. *The section "Trigger for Interest" displayed during the PDF download is shown by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Countermeasures for red rust deterioration of water supply pipes: "Piping Magnetite Method" *NETIS registered

By installing a water modification device, the red rust in the pipes changes to black rust, restoring the thickness of the degraded pipes!

The "Piping Magnetite Method" is a technique that uses the water quality improvement device "The Bio Water" to convert the red rust in water supply pipes into black rust (ferric oxide), aiming to extend the lifespan of the piping. The modified water forms a dense and continuous coating of calcium carbonate and other substances inside the pipes. As the red rust transforms into black rust, it repairs and restores the corroded areas of the degraded pipes. This method allows for improvements in the blockage rate of the pipes and prevents leaks and the occurrence of red water, all at a low cost and within a short construction period. Depending on the hardness, it is generally maintenance-free, thus reducing maintenance costs and efforts. 【Features】 ■ NETIS registered [KT-160125-A] ■ Installation involves simple construction at the water supply pipe's origin, with a short construction period of about half a day to one day ■ There is no need to replace the pipes, allowing for low-cost measures against red rust ■ The effects are semi-permanent, enabling the use of water supply pipes for the lifespan of the building ■ Reduces BOD in wastewater, thereby lessening the environmental impact on water *From the download link below, you can view materials introducing the "Piping Magnetite Method" and the product catalog for "The Bio Water" all together. *The section titled "Trigger for Interest" displayed during the PDF download is generated by AI from Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The Bio Water (BW System) Pipeline Magnetite Method

Measures against the deterioration of water supply pipes! A piping magnetite method to reduce costs for large-scale repairs.

By installing The Bio Water in the water supply pipe, it changes the quality of the water and slows down the oxidation rate of iron, promoting the formation of a stable oxidation film (black rust) inside the piping. Existing red rust will also transform into black rust. Since black rust has a density about ten times higher than red rust, the blockage rate of the piping will also improve. Additionally, piping that has lost thickness due to deterioration and is on the verge of leaking can be restored to its original thickness through black rust formation, thus avoiding the risk of leakage. 【Features】 ○ Low cost ○ Short construction period ○ Principally maintenance-free ○ Can be safely used in water supply pipes until the building's lifespan *For more details, please contact us or download the catalog. *The section titled 'Reason for Interest' displayed during the PDF download is generated by Ipros Inc.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Black Rust Effect Case Study: Maison Excellent (Sakae Ward, Yokohama City)

Even after 23 years of installation, the black rust effect continues! Introducing a case study from Maison Excellent (Sakae Ward, Yokohama)!

Here is a case study of Maison Excellent (Sakae Ward, Yokohama City). In a condominium built in 1989, "The Bio Water" was installed in 1992. After 23 years, in 2015, the pipes were removed along with the adjacent room that did not have the installation, allowing for a comparison of the two. The sharp peaks observed in the modified water indicate the presence of rust-resistant magnetite and maghemite. In contrast, the unmodified water showed the presence of oxyhydroxide iron, as well as goethite and ferrihydrite, which are components of red rust. 【Qualitative Analysis Results of Modified Water】 ■ Modified Water (Room 201) - Type of Rust: Black Rust - Condition of Rust Attachment: Hard and difficult to peel off - Detected Substances: Mostly magnetite and maghemite, with very small amounts of goethite and ferrihydrite. *For more details, please refer to the related link page or feel free to contact us. *The section "Trigger for Interest" displayed during the PDF download is generated by Ipros Inc.'s AI.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Pipeline Magnetite Method] NTT-AT Creative Co., Ltd.

Clear water within one month of installation! Introducing examples of measures against pipe deterioration and red water in circulation cooling lines.

From November 2016 to June 2017 (for 8 months), a field test was conducted at the NTT-AT Creative Corporation headquarters factory (Tokushima Prefecture) on the circulating cooling line, aimed at addressing pipe deterioration and red water issues. A water conditioning device called The Bio Water (Punch Box: hereafter PB) was installed in the water tank of the sealed circulating cooling line, and the changes in iron content and color of the water in the tank were regularly monitored. The water used is municipal water. During the test period, the water was not replaced, but approximately 20L/month of supplementary water was added. One month after the introduction of the "Pipe Magnetite Method," the red water became clear. After that, the iron content and color fluctuated several times, gradually stabilizing to a clear water quality. [Overview] ■ November 2016 to June 2017 (for 8 months) ■ NTT-AT Creative Corporation headquarters factory (Tokushima Prefecture) ■ A field test was conducted on the circulating cooling line to address pipe deterioration and red water issues. *For more details, please refer to the related links or feel free to contact us. *The section titled "Trigger for Interest" displayed during the PDF download is generated by AI from Ipros Corporation.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Energy Saving Effect Measurement Case] Chiller for Clean Room Air Conditioning System

Power consumption decreased by 30% within two months after installation! Introducing the energy-saving effects of the refrigeration unit using the water reforming device "The Bio Water."

We would like to introduce a case study measuring the energy-saving effects of our clean room air conditioning system's refrigeration unit. A water conditioning device, The Bio Water, was installed in the cooling tower's (350RT) water tank, and changes in water quality were measured, along with changes in the power consumption of the refrigeration unit's compressor. Additionally, we confirmed the changes in the replacement cycle of the filters installed in the cooling water for production equipment. The power consumption of the refrigeration unit's compressor decreased by 30% within two months after the installation of The Bio Water. This was due to the removal of scale in the cooling water piping circulating from the cooling tower to the refrigeration unit, resulting in a reduced load on the compressor and confirming the energy-saving effect. [Test Overview] ■ Test Location: Taichung City Precision Injection Molding Factory ■ BW Installation Date: November 14, 2018 - Installation of The Bio Water in the cooling tower ■ Test Period: November 14, 2018 - January 25, 2019 ■ Test Content: Measurement of energy-saving effects of the refrigeration unit in the clean room air conditioning system * The production equipment installed in the clean room includes injection molding machines and deposition devices. * For more details, please refer to the PDF document or feel free to contact us.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Improvement of Antioxidant Power Case] Removal of Active Oxygen by The Bio Water Modified Water

The antioxidant power is improved by more than 2 to 6 times compared to tap water! Here are some examples of The Bio Water modified water.

We will introduce a case study measuring which has greater antioxidant power: The Bio Water Modified Water (flow treatment type, direct connection) or tap water. Superoxide, a type of reactive oxygen species, was artificially generated, and we measured which had a greater ability to eliminate superoxide when modified water was added versus when tap water was added, using the electron spin resonance (ESR) method. Tap water eliminated 40 units, while modified water eliminated 86 units, indicating that modified water has 2.15 times the reactive oxygen removal capability of tap water. [Measurement Overview] ■ Measurer: Aging Control Inspection Department, Japan Aging Control Research Institute Additionally, in a case where the sister product, Elan Vital, was soaked in 500ml for 2 hours, measurements using the electron spin resonance method for superoxide showed that the modified water has a 6-fold improvement in reactive oxygen removal function, which is said to be a cause of disease and aging. *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Trigger for Interest' displayed during PDF download is generated by AI from Ipros Co., Ltd.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Ion Exchange Resin Longevity Case Study] Yanagisawa Seiki Co., Ltd. Kawasaki Factory

Here is an example of extending the life of ion exchange resin in the case of wire cut electrical discharge machining!

The processing fluid (40L) for wire cut electrical discharge machining was treated with tap water (from Kawasaki City) using a BW device, and the treated water was added each time the processing fluid was replenished. The lifespan of the ion exchange resin was compared over a period of 5 months with and without BW treated water. As a result, the lifespan of the ion exchange resin with untreated BW water was 1400 hours, while with treated water it was 2924 hours, demonstrating approximately double the ion exchange capacity. Additionally, the movement of the movable wire guide became stable, and the phenomenon of poor movement was eliminated, significantly reducing machine stoppages during unmanned operation. 【Case Overview】 ■ Machine Type: Sodick AQ300L ■ Test Method - Treated tap water (from Kawasaki City) with BW device for processing fluid (40L) - Added treated water when the processing fluid decreased - Compared the lifespan of ion exchange resin with and without BW treatment *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Reason for Interest' displayed during the PDF download is generated by the AI of Ipros Co., Ltd.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Ion Exchange Resin Longevity Case Study] Victor Company of Japan, Limited

The lifespan of ion exchange resin has improved by about 40%! Here are some installation examples of The Bio Water.

This verification was conducted at the Kurihama Research Institute of Victor Company of Japan, Limited. The difference in the lifespan of the ion exchange resin was measured between cases where The Bio Water was installed just before the ion exchange resin and cases where it was not installed. When The Bio Water was attached, we confirmed how much longer the lifespan of the ion exchange resin could be extended. As a result, when the water activator was attached, the usage period was 62 days, compared to 45 days without it, allowing for an extension of 17 days (approximately 38%). [Test Conditions] - Ion Exchange Resin: Nippon Rensui Co., Ltd. C-40S (resin amount 40 liters) - Water Conditioning Device: Urban Expansion Co., Ltd. Ceramic Water Activator The Bio Water - Measuring Instrument: Kurita Water Industries Ltd. Water Quality Meter KD-32 *For more details, please refer to the PDF document or feel free to contact us. *The section "Trigger for Interest" displayed during the PDF download is generated by AI from Ipros Co., Ltd.

  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Magnetite Pipe Method Case Study] Shibaura Mechatronics Corporation Building No. 2

The shape and quality of the rust that can form are completely different, and it has been confirmed that it is effective in preventing the deterioration of the water supply pipes!

Here is a case study of Shibaura Mechatronics Co., Ltd. Building No. 2 (Yokohama City, Kanagawa Prefecture). The water from the circulating water system's cushion tank (WT2) was treated with The Bio Water. As a comparison, the cushion tank (T2) from the clean room air conditioning system was used as an untreated control tank. Test pieces were placed in each tank for comparison. As a result, it was confirmed that the shape and quality of rust that could form were completely different with and without The Bio Water, demonstrating its effectiveness in preventing the deterioration of the water supply pipes. 【Test Pieces Used】 - Two types were set: thin plates of soft iron (Test Piece 1) and joints of GP pipes with the zinc plating removed (Test Piece 2). - Five sets of each were placed in each tank. *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Reason for Interest' displayed during PDF download is generated by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Improvement of Cleaning Ability Case Study] Certain Copier Manufacturer

Heat roll yield 100%! Cleaning power has improved.

Here is a case study from a certain copier manufacturer. The heat roll can be considered the heart of products such as copiers. If the heat roll is not perfectly round, it will cause unevenness in the printing surface, making the round shape crucial. Therefore, we conduct thorough inspections on all products and sometimes perform manual polishing. The yield rate for this component has improved by about 1% each year, but it has plateaued at 95%. By adding a BW device to the hot water washing machine after polishing to improve the quality of the water, the yield rate increased from 95% to 100%. [Case Study] ■ Before BW installation: Yield rate 95% ■ After BW installation: Yield rate 100% *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Trigger for Interest' displayed during the PDF download is generated by Ipros Inc.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Improvement of Cleaning Ability Case] Odawara CMS_Hitachi Storage Division

The degradation rate of the solvent is reduced by half, and the cleaning power of pure water is improved!

We would like to introduce the results of the effect analysis of The Bio Water conducted by the Odawara CMS, a division of Hitachi, Ltd.'s Storage Division. After the installation of The Bio Water, the degradation rate of the solvent cleaning solution was reduced to less than half, significantly improving the cleaning capability. No scale (silica, needle-like crystals of calcium) has occurred in the filter tank. These effects were observed two weeks after the installation of The Bio Water. You can check the evaluation of the installation of The Bio Water in the "PDF Download" section below regarding the "Package Board Pure Water Cleaning Device." The report sent from the other party is published without any modifications, so please take a look. *For more details, please refer to the PDF materials or feel free to contact us. *The section "Trigger for Interest" displayed during the PDF download is shown by Ipros, Inc.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study on Wastewater BOD and Sludge Reduction] Ricoh Company, Ltd. Ebina Factory

We will introduce a case study of a lab test for reducing excess sludge treatment costs!

We would like to introduce a case study of a laboratory test conducted at Ricoh's Ebina Plant to reduce excess sludge treatment costs. As a result of three BOD comparison tests, an average reduction of approximately 20% in BOD was confirmed. In this test, the wastewater was diluted by half. However, in actual use, since the entire wastewater is modified, a BOD reduction of about 40%, which is double the test results, can be expected. 【Method of BOD Laboratory Test】 1. Collect 1 liter each of inflow and outflow water from Ricoh's Ebina Plant. 2. Divide the inflow into 500ml portions, labeling them A and B. Similarly, divide the outflow into 500ml portions. Further, modify inflow A with BW (Bio Water). 3. Mix inflow A with outflow A, and inflow B with outflow B (since it's 500ml each, the ratio is 1 to 1). 4. Measure the BOD of the BW-treated water and untreated water (using the 20°C 7-day incubation method). *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Reason for Interest' displayed during the PDF download is generated by AI from Ipros Inc.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study on Wastewater BOD and Sludge Reduction] Ohtaki Co., Ltd. Ibaraki Factory

The installation of The Bio Water reduced sludge by 77% in 3 months!

We would like to introduce a case study from Ohtaki Co., Ltd. at the Ibaraki factory. Out of the two automatic washing lines in the oshibori laundry factory, we installed the water conditioning device The Bio Water Ω80 on one line and compared the finished products from the line with the conditioning device and the line without it. Since we cannot meet the wastewater standards (BOD25) of Mito City, we are investigating the impact of water conditioning on wastewater. *For more details, please refer to the PDF document or feel free to contact us. *The section titled "Reason for Interest" displayed during the PDF download is generated by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study on Wastewater BOD and Sludge Reduction] Mr. N's Residence in Kouzutsu, Odawara City, Kanagawa Prefecture

The amount of sludge in the purification tank has drastically decreased by 80%, and the transparency of the water inside the tank has also surged!

We would like to introduce a case study from Mr. N's residence in Kōzu, Odawara City, Kanagawa Prefecture. Before the installation of The Bio Water, the activated sludge in the septic tank increased from 20% to 70-80% over three months. After the installation of The Bio Water, it dramatically decreased to 5%. The water clarity of the septic tank also surged from an average of 9.3 cm before installation to an average of 16 cm after installation, and the amount of dissolved oxygen, which activates aerobic microorganisms that consume sludge, also increased. You can check the changes in "SV values of sludge (sludge settling rate) and water clarity of Mr. N's septic tank" in tables and graphs from the "PDF Download" below. Please take a look. *For more details, please refer to the PDF materials or feel free to contact us. *The section "What sparked your interest?" displayed during the PDF download is generated by AI from Ipros Inc.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Scale Countermeasures Case Study] Hotel Diamont (Niigata City) Two Cooling Towers

Six months after the installation of The Bio Water, scale in the cooling tower has noticeably detached, and red rust has also been suppressed!

We would like to introduce a case study of two cooling towers at Hotel Diamont (Niigata City). We conducted a scale detachment test. The testing method involved installing two The Bio Water Punch Boxes in one of the two cooling towers under the same conditions. We performed "scale attachment status" and "cooling water salt chamber analysis" at each location. In the cooling tower where The Bio Water Punch Box was installed, the packing material naturally detached the scale. The water quality test of the cooling water demonstrated that The Bio Water has excellent rust prevention and scale detachment effects. [Case Study] ■ Testing Method - Installed two The Bio Water Punch Boxes in one of the two cooling towers under the same conditions. - Conducted "scale attachment status" and "cooling water salt chamber analysis" at each location. *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Reason for Interest' displayed during the PDF download is generated by Ipros Co., Ltd.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Scale Measures Case Study] Hitachi Computer Equipment Co., Ltd. (Odawara City)

The bio-water installation eliminated scale in the pipes within 4 months!

Here is a case study of Hitachi Computer Equipment Co., Ltd. (Odawara City). A scale removal field test was conducted. The Bio Water was installed in the boiler feed water piping and makeup water piping on the premises. Two months later, significant scale suppression effects were observed at three locations: the interior of the boiler water pipes, the inner wall surfaces, and the screws of the inspection ports. By four months later, the scale was completely suppressed, and the existing scale began to be removed. [Case Study] ■ Location: Boiler feed water piping and makeup water piping on the premises ■ Two months later - Significant scale suppression effects were observed at three locations: the interior, inner wall surfaces, and screws of the inspection ports ■ Four months later - Scale was completely suppressed - Existing scale also began to be removed *For more details, please refer to the PDF document or feel free to contact us. *The section "Reason for Interest" displayed during the PDF download is generated by Ipros Co., Ltd.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Scale Measures Case Study] Ryouzen Nishi-Shinjuku Store (Bento Delivery - Tokyo)

The bio-water peeled off the scale in the boiler inner tube after 2 weeks at 1/3 concentration!

We would like to introduce a case study from Rishin Nishi-Shinjuku Store (Bento Delivery, Tokyo). A scale removal field test was conducted. The Bio Water 1/3 was installed in the hyper steamer. Before installation, it was completely filled with scale, but after 2 weeks of installation, the scale began to peel off. [Case Study] ■ Location: Installation of Bio Water 1/3 in the hyper steamer *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Trigger for Interest' displayed during PDF download is generated by Ipros Inc.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Mechanism of scale measures

The mechanism of scale removal and prevention by The Bio Water!

Scale refers to the phenomenon where calcium carbonate (CaCO3) or silicon dioxide (silica, SiO2) precipitates and adheres to pipes and water supply and heating equipment. We will introduce the reaction mechanism of scale detachment and prevention through water modification by The Bio Water. In the case of calcium carbonate (CaCO3), with The Bio Water modified water, gases that were dissolved under high pressure do not vaporize but are encapsulated within the chain of water molecules (hydration), maintaining a stable state among uniformly sized water molecules. As a result, CaCO3 reacts with water and the abundant CO2 to become water-soluble Ca(HCO3)2. CaCO3 + H2O + CO2 → Ca(HCO3)2 In the case of silicon dioxide (silica, SiO2), a phenomenon occurs where water molecules surround the silica SiO2 in the modified water. This makes it difficult for the silica SiO2 to bond laterally, hindering the formation of a gel membrane and making it less likely for a strong deposit layer to form as scale. On the other hand, in unmodified water, a strong layered gel membrane is formed. SiO2 + H2O → H2SiO3 *For more details, please refer to the PDF document or feel free to contact us.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Antibacterial Effect Case Study] Matsubara Trading Co., Ltd. Tulip Cultivation Farm

The suppressive effect of water mold in hydroponics! Shoots have emerged from all the bulbs.

Here is a case study of Matsubara Trading Co., Ltd.'s tulip cultivation farm in Fujimi City, Saitama Prefecture. The tulip bulbs for hydroponic cultivation had a waste rate of about 13%, with 1-2% upon arrival, 3% due to mold during storage, 3% due to poor germination and rooting, and 6% not producing buds. To address this, the hydroponic water was modified with The Bio Water. All bulbs sprouted. Subsequently, they grew smoothly, achieving an almost 100% yield. Additionally, all the mold on the bulbs was eradicated. [Case Study] ■ Issue: Waste rate of about 13% ■ Proposal: Modify hydroponic water with The Bio Water ■ Results - All bulbs sprouted - Grew smoothly, achieving an almost 100% yield - All mold on the bulbs was eradicated *For more details, please refer to the PDF materials or feel free to contact us. *The section titled 'Trigger for Interest' displayed during the PDF download is generated by Ipros Co., Ltd.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Antibacterial Effect Case Studies] Two companies in Tohoku (Company A, Company P) and one company in Kansai (N Ironworks)

The phenomenon of spoilage in water-soluble cutting oils is eliminated! A comparison between The Bio Water modified water and tap water.

We will introduce the cases of two companies in Tohoku (Company A and Company P) and one company in Kansai (N Steel Works). A comparison (survey) was conducted between The Bio Water modified water and tap water. Measurements were taken every Tuesday and Friday at 1 PM by veteran craftsmen with over 20 years of experience in metal processing. You can check the results of the measurements for 11 items, as well as changes in the cutting process due to the water quality of water-soluble cutting oils, from the "PDF Download." Please take a look. 【Implemented Items (Partial)】 ■ Dirt around the machine ■ Condition of the sliding oil on the surface of the cutting oil ■ Sludge condition inside the cutting oil tank ■ Bacterial (germ) proliferation condition ■ Intensity of unpleasant odors *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'Trigger for Interest' displayed during the PDF download is generated by AI from Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Antibacterial Effect Case Study] Kanagawa Prefectural Industrial Technology Center

Outstanding antibacterial power! Bacteria began to decrease immediately after E. coli inoculation, and after 8 hours, it was almost zero!

We would like to introduce the lab data of the case study "Sister Product Elan Vital" from the Kanagawa Prefectural Industrial Technology Center. The bacteria began to decrease immediately after inoculation with E. coli, and after 8 hours, it was almost zero. Even after one day, the bacteria did not increase, so it is safe to carry at room temperature. In addition, you can check the "Factory Comparison Data of The Bio Water" from Aqua Pier Co., Ltd. (Osaka Prefecture) and more through the "PDF Download." We have published several examples of antibacterial effects. Please take a look. *For more details, please refer to the PDF materials or feel free to contact us. *The section "Trigger for Interest" displayed during the PDF download is shown by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Antibacterial Effect Case Study] Kitasato Environmental Science Center (Foundation)

It has about 5 times the antibacterial power against Legionella bacteria and about 4 times against O-157 bacteria!

We will introduce a case study from the Kitasato Environmental Science Center (Foundation). The test waters are "tap water" and "The Bio Water Modified Water." Each was placed in a 1L glass bottle, into which Legionella bacteria and O-157 bacteria were injected. The bottles were kept 3 meters apart and, immediately after sampling, as well as one day and two days later, the colony counts of each bacterium in the test waters were measured. You can check the test results by downloading the PDF. *For more details, please refer to the PDF materials or feel free to contact us. *The section titled 'Trigger for Interest' displayed during the PDF download is generated by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Antibacterial Effect Case Study] Professor Jun Sawai, Department of Applied Chemistry, Kanagawa Institute of Technology

Even after one week, there was zero occurrence of general bacteria (tap water showed growth after four days)! Here are examples of antibacterial effects.

We would like to introduce a case study by Professor Jun Sawai from the Department of Applied Chemistry at Kanagawa Institute of Technology. The samples used were "The Bio Water Modified Water," "Tap Water," "Distilled Water," and "Sterilized Distilled Water." 500ml of each of the four samples was prepared in two sterilized beakers. A small amount of the sample water was taken daily, and the total viable count was measured using the colony count method (standard agar medium from Eiken Chemical). 【Case Study Results】 ■ BW Modified Water: No bacteria were detected ■ Tap Water: Bacteria appeared after 5 days ■ Distilled Water: Bacteria appeared on the same day ■ Sterilized Distilled Water: No bacteria were detected *For more details, please refer to the PDF document or feel free to contact us. *The section "Trigger for Interest" displayed during the PDF download is generated by AI from Ipros Inc.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Magnetite Pipe Construction Method Case Study] Seki Cleaning Store (Katsushika Ward, Tokyo)

Ten years after the installation of The Bio-Water, a magnificent layer of black rust covered the pipe walls!

Here is a case study of the Seki Cleaning Shop (Katsushika Ward, Tokyo). Ten years after the installation of The Bio Water, when the pipe was removed, a remarkable black rust coating covered the pipe wall (the type of pipe is GP pipe). At this point, the deterioration of the piping stops, and there are no leaks. Additionally, you can check the cases of Show Special Manufacturing Co., Ltd. (Kawasaki City) and Shikaoi Junior High School (Hokkaido) from the "PDF Download." *For more details, please refer to the PDF materials or feel free to contact us. *The section titled 'Trigger for Interest' displayed during the PDF download is generated by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Magnetite Pipe Method Case Study] Kosodate Heights Building J (Tokorozawa City, Saitama Prefecture)

I will introduce how the rust at the joint of the coupling and the rust that forms between the vinyl coating and the base metal has changed five years after the installation of The Bio Water!

Here is the translation: We would like to introduce a case study of the "Shoshin Finger Heights Building J" located in Tokorozawa City, Saitama Prefecture. After investigating methods to prevent deterioration of the water supply pipes 20 years after construction, we installed The Bio Water following a year-long field test. The type of water supply pipe in this building is "internally coated lined steel pipe." This type of pipe is protected by a vinyl coating on the inside, but the ends of the pipes where they connect are exposed, leading to the progression of red rust from that area. Additionally, water can enter between the vinyl coating and the exposed metal, causing corrosion of the iron without notice, which eventually leads to leaks. We will introduce what happened to the two types of rust—"rust at the joint connection" and "rust that forms between the vinyl coating and the exposed metal"—five years after the installation of The Bio Water. [Five Years After The Bio Water Installation] ■ Rust at the Joint Connection - A white calcium layer has formed on the exposed metal part of the joint, with a strong black rust layer underneath. - Not only is there black rust, but a calcium layer has also formed on top of it. - When the calcium layer is removed, the black rust underneath appears to have formed around the exposed metal of the joint as if it were artificially welded. *For more details, please refer to the PDF document or feel free to contact us.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Magnetite Piping Method Case Study] JR Takasaki Station (Takasaki City, Gunma Prefecture)

Check and analyze the condition of the test pieces (untreated tap water, untreated well water, BW mixed water)!

Here is an example from JR Takasaki Station (Takasaki City, Gunma Prefecture). Due to the mixing of well water with the tap water, scale issues occurred in the station's shops. After installing The Bio Water in the shops for one year and observing the results, it was confirmed that scale adhesion was suppressed. In light of this result, we conducted the following tests to determine whether installing The Bio Water throughout the entire station building would be effective in suppressing scale and addressing the deterioration of the water supply equipment due to rust. From the measurement data of the roughness gauge, it was found that the mixed BW treated water had a smaller surface roughness, and corrosion was progressing slowly across the entire surface. [Test Overview] ■ Test Method - The condition of test pieces (untreated tap water, untreated well water, BW mixed water) was checked and analyzed four times: at installation, 3 months later, 6 months later, and 23 months later. ■ Equipment Used - The Bio Water Omega-100 - Punch Box (16 pieces) *For more details, please refer to the PDF document or feel free to contact us. *The section titled 'What sparked your interest' displayed during the PDF download is generated by Ipros Inc.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Piping Magnetite Method Case Study] JR East South Nagasaki Housing

Is there really black rust forming after the installation of The Bio Water? Proof of magnetite formation!

Here is an introduction to the case of JR East Japan Minami-Nagasaki Housing (Minami-Nagasaki, Toshima Ward, Tokyo). We conducted a demonstration of magnetite (black rust) formation using the "Piping Magnetite Method." After 14 months of installing The Bio Water, we quantitatively analyzed the rust components to determine if black rust had indeed formed. When the ratio of divalent iron to trivalent iron in the rust is 1:2, it can be classified as black rust (i.e., magnetite Fe3O4). As a result, the divalent iron measured 0.6 and the trivalent iron measured 1.3, giving a ratio of approximately 1:2. Given that the component ratio is nearly 1:2, we can conclude that this rust is indeed black rust. 【Case Overview】 ■ Test Methods - Qualitative analysis of rust components in the water supply pipe using fluorescent X-ray analysis - Blockage rate of the water supply pipe using a gamma-ray piping diagnostic device - Measurement of remaining wall thickness using an ultrasonic thickness gauge - Water quality testing (iron content testing / conducted 9 times) *For more details, please refer to the PDF document or feel free to contact us. *The section titled "Reason for Interest" displayed during the PDF download is generated by the AI of Ipros Inc.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

What is the piping magnetite method (TM)?

From red rust to black rust! The 'Piping Magnetite Method (TM)' industrializes traditional techniques!

The core technology of the "Piping Magnetite Method (TM)" is water modification. The water modification method that has been used in Japan for a long time utilized natural minerals. We perform water modification using artificially developed mineral crystals. This modified water changes the calcium carbonate film that forms on metal surfaces due to rust reactions into a denser form than usual. This dense film reduces the amount of oxygen supply near the base metal under the rust layer. As a result, the progression of oxidation slows down, and red rust transforms into black rust. This black rust repairs and restores the areas eroded by red rust back to their original thickness, extending the lifespan of the water supply pipes. 【Features】 ■ Applicable to leaking pipes ■ Low cost ■ Short construction period ■ Maintenance-free in principle ■ Usable until the lifespan of the building ■ Positive effects on drainage pipes ■ Feasibility tests can be conducted in the lab *For more details, please download the catalog or contact us. *The section "What sparked your interest?" displayed during the PDF download is shown by Ipros Co., Ltd.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Information] The piping magnetite method, where the traditional technique of water quality improvement has become an industrial technology.

One construction site for the Great Yuan is OK! Introducing the positioning of the piping magnetite method by the Japan Waterworks Association!

This document introduces the "Piping Magnetite Method," which allows for the restoration of corroded pipes and prevention of leaks without touching the pipes. It provides detailed explanations using diagrams and photos on topics such as "the difference between red rust and black rust," "the relationship between mineral crystals and water modification," and "the locations of red rust deterioration in VLGP pipes." Additionally, you can view case studies and comparisons with other methods. We encourage you to read it. [Contents (excerpt)] ■ What is the "Piping Magnetite Method"? ■ Changing water quality without touching the pipes ■ "Restoration" rather than "prevention" ■ Effects extending to drainage pipes ■ Comparison with other methods *For more details, please refer to the PDF document or feel free to contact us. *The section titled "What sparked your interest?" displayed during the PDF download is generated by Ipros Co., Ltd.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Piping Magnetite Method] BOD decreased from 25 to 2.6!

Improving the water environment! Introduction of a case study on the piping magnetite method to reduce BOD load.

We would like to introduce a case study from Ohtaki Co., Ltd.'s Ibaraki factory, which has implemented our proposed "Piping Magnetite Method." In the company's oshibori laundry factory, one of the two automatic cleaning lines was equipped with a water conditioning device, "The Bio Water Ω80." A comparison was made between the product quality of the line with the conditioning device and the line without it. As a result, the BOD levels decreased from 25 to 2.6 after the installation of the device, clearing the city's standard values within three months. Additionally, we have materials that cover all topics available for your reference. [Case Study] ■ BOD Reduction in Wastewater Field Test ■ Location: Ohtaki Co., Ltd. Ibaraki Factory ■ Duration: March 13, 2005 - June 13, 2005 *For more details, please refer to the PDF document or feel free to contact us. *The section "Trigger for Interest" displayed during the PDF download is generated by AI from Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study of Piping Magnetite Method] Water Quality Inspection in the Water Storage Tank of the Circulating Cooling Water Line

Conducted water quality tests four times! Introducing a case where the piping magnetite method was implemented as a countermeasure against red rust in the cooling water line.

We would like to introduce a case study of NTT-AT Creative Co., Ltd., located in Itano-gun, Tokushima Prefecture, which has implemented our proposed "Piping Magnetite Method." The company has taken measures against red rust in the cooling water line by placing four punch boxes in the water storage tank (10t) of the circulating cooling water line. They collected water from the storage tank every week and conducted water quality tests four times. As a result, water quality improved, and the components of red rust that had dissolved in the water transformed into black rust. The issue of red water was resolved. Additionally, we have materials that cover all topics available for your review. [Case Study] ■ Measures against red rust in the cooling water line ■ NTT-AT Creative Co., Ltd. (Itano-gun, Tokushima Prefecture) ■ Installation of punch boxes (November 12, 2016) *For more details, please refer to the PDF document or feel free to contact us. *The section titled "Trigger for Interest" displayed during the PDF download is generated by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Free explanatory materials available!] Clarification of the mechanism of red rust turning into black rust and development of measurement devices.

Completed as industrial technology! Information on the piping magnetite method process and coating resistance measurement method is included!

This document explains the mechanism of black rust formation from red rust using the "Piping Magnetite Method" and the development of measurement devices. It provides detailed information about the "process of the Piping Magnetite Method" and "devices for measuring the degree of water modification," accompanied by diagrams and photographs. Additionally, patents have been obtained both domestically and internationally. We encourage you to read it. We also introduce materials that cover all topics. [Contents] ■ Process of the "Piping Magnetite Method" (Formation of calcium film) ■ Process of the "Piping Magnetite Method" (Formation of iron oxide under the calcium film) ■ Process of the "Piping Magnetite Method" (Completion of the Piping Magnetite Method) ■ Device for measuring the degree of water modification (Film resistance measurement method) ■ Patent certificate *For more details, please refer to the PDF document or feel free to contact us. *The section "Trigger for interest" displayed during PDF download is generated by the AI of Ipros Co., Ltd.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study Included] Piping Magnetite Method

Change water quality without touching the pipes! Introducing a method that only requires construction at one main location.

The "Piping Magnetite Method" is a technique that has transformed traditional water purification technology into an industrial process. Instead of natural stones, artificial mineral crystals are used, industrializing the traditional techniques. It repairs rusted pipes without touching them, restoring the pipe thickness and allowing for leaks. Using "The Bio Water," we conducted a three-dimensional measurement to see how the wall thickness of new GP pipes changes after 10 years. The results from measuring the wall thickness at 20 locations showed that in all cases, the thickness increased compared to when they were new. Additionally, we also provide materials that cover all topics. 【Features】 ■ Repairs rusted pipes without touching them ■ Restores pipe thickness and allows for leaks ■ Changes water quality without touching the pipes ■ Installation is sufficient at one main point ■ Uses artificial mineral crystals instead of natural stones *For more details, please refer to the PDF materials or feel free to contact us. *The section titled "What sparked your interest" displayed during the PDF download is shown by Ipros Co., Ltd.'s AI.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water Quality Improvement Device "The Bio Water"

Measures against red rust, red water, and scale that can be installed directly on water pipes! It also has the effect of forming black rust that prevents the progression of rust!

We have developed "The Bio Water," a new technology aimed at fundamentally changing the water environment by transforming tap water into water resembling the pure spring water found in the mountains. This device is equipped with a self-assessment system that determines its own water modification capability and is completed as an industrial technology. By simply installing it in the water supply pipes, tap water undergoes physical changes to resemble spring water, effectively addressing issues such as red rust, red water, and scale, while also forming black rust that prevents the progression of rust. 【Features】 ■ Significant reduction in sludge volume in septic tanks ■ Extended lifespan of ion exchange resins ■ Natural detachment of scale ■ No decay even after one week ■ Rust and corrosion prevention in water supply pipes *For more details, please request materials or view the PDF data available for download. *The section titled 'What sparked your interest?' displayed during the PDF download is generated by the AI of Ipros Inc.

  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Water Purification Device

Water purification device

This is a live water device that connects directly to pipes and neutralizes without removing chlorine! 【What is activated water?】 The chlorine in activated water is hydrated, so it does not bond with other elements. It retains its disinfection capability and produces safe and vital water, which is Bio Water. === Main Usage Locations (excerpt) === ● Disk, semiconductor, and substrate manufacturing ● Food manufacturing factories ● Medical facilities ● Brewing industry ● Office buildings ● Production farms, shipping locations, cut vegetable factories ● Saunas, pools, bathing facilities ● Livestock industry ========================= Published Patent: No. 11-33541 Published Patent: No. 2000-107752 Utility Model Registration: No. 1888871 Design Registration: No. 33599 Trademark Registration: No. 120935 Japan Water Works Association Water Supply Equipment Certification Registration: No. Z-92, Z-93 Ministry of Health, Labour and Welfare Water Supply Law Standard Compliance: No. JIS-3200-07 ========================= *For more details, please refer to the materials and catalog.

  • others

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration
Prev 1 Next
  • ケーブルマーキングや銘板などに! 耐水性 耐薬性 耐熱性 耐擦過性 ブラザー独自構造のラミネートラベル 実物ラベル サンプルプレゼント!
  • イプロスがリアル展示会を主催します! AI/DX 営業・マーケティング展 出展社募集中 リード数・商談数が止まらない!新しいリアル展示会を提供 会期 2026年3月24日(火)~25日(水) 会場 東京ビッグサイト東4ホール 出展概要資料を進呈!
    • Contact this company

      Contact Us Online
    • Before making an inquiry

      Download PDF

    Products

    • Search for Products

    Company

    • Search for Companies

    Special Features

    • Special Features

    Ranking

    • Overall Products Ranking
    • Overall Company Ranking

    support

    • site map
    IPROS
    • privacy policy Regarding external transmission of information
    • terms of service
    • About Us
    • Careers
    • Advertising
    COPYRIGHT © 2001-2025 IPROS CORPORATION ALL RIGHTS RESERVED.
    Please note that the English text on this page is automatically translated and may contain inaccuracies.