The reality is that a UPS (Uninterruptible Power Supply) alone cannot handle failures. A combination of a UPS and an STS (Static Transfer Switch) can achieve high reliability in power supply.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "ATS-Plus" is a thin, compact, and highly reliable switch. It can be used with any type of power source, including commercial power, UPS, generators, and inverters. You can choose between "Single-phase 2-wire AC100V 15A" or "AC100V 30A." Additionally, by using the included CD-ROM, you can customize the switching conditions. 【Features】 ■ Thin and compact ■ Switching time during automatic switching in case of power failure: approximately 8-12 msec ■ Usable with any type of power source ■ Ability to customize switching conditions ■ Complies with safety certification standards *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "ACRS-B" is a power switch that complies with the Electrical Appliance and Material Safety Law (PSE Law). It supports single-phase two-wire, AC100V, and 15A. It automatically switches during power outages or maintenance. Additionally, this product has been selected by Japan Post Information Technology and is scheduled to be gradually introduced for power backup at major post offices nationwide starting in the fiscal year 2022. 【Features】 ■ Supports single-phase two-wire, AC100V, and 15A ■ Automatically switches during power outages or maintenance ■ Outlet type ■ Easy backup *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "ACRS-A" is a power switch that supports single-phase two-wire systems with a maximum of 6000VA. With optional mounting brackets, it can be installed in a 19-inch rack. It automatically switches during power outages or maintenance. It can be used with any type of power source, including commercial power, UPS, generators, and inverters. 【Features】 ■ Height: 1U (44mm) ■ Switching time during automatic switching in case of power outage: approximately 2 seconds ■ Usable with any type of power source ■ Can be mounted in a 19-inch rack with optional mounting brackets ■ Supports single-phase two-wire systems with a maximum of 6000VA *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document discusses the synchronization relationship between two AC power sources, A and B, in a switch that inputs these two systems. In switching between two AC power sources, the ideal switch is one where the waveforms before and after the switch appear almost unchanged from the load side. In high-speed power switching, synchronized switching is essential, and it is necessary to switch at a timing where the phase difference between the two power sources is minimal. Furthermore, the synchronization relationship of the two power sources can be classified into two types: "sources that each have their own unique frequency" and "sources that are under synchronized control." For more detailed information, please refer to the related links below. [Overview] ■ In switching between two AC power sources, the ideal switch is one where the waveforms before and after the switch appear almost unchanged from the load side. ■ When switching with a phase difference between the two power sources, there may be inrush current depending on the load equipment, so it is necessary to consider the impact on the load equipment. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAt the Hatsuratsu no Sato light-cost elderly home in Chiba City, Chiba Prefecture, following the experience of a large-scale power outage caused by Typhoon No. 15 in 2019, efforts were made to aim for a nursing facility that could avoid the risks of power outages by considering the introduction of emergency power generation equipment. As a result, one backup emergency generator of 45kVA and one of 50kVA were installed. By automatically switching the power supply during a power outage, it became possible to safely switch the power without direct operation by employees, even in emergencies. This allowed for long-term backup of essential infrastructure such as lighting and air conditioning necessary for facility operations, enabling business continuity during power outages. [Case Overview] - Production of a power switching panel that automatically switches to emergency generators in preparation for disasters - Installation site: Hatsuratsu no Sato light-cost elderly home, Chiba City, Chiba Prefecture - Products introduced: Custom switch TGM-PS *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA certain automobile manufacturer had critical load equipment that could not be powered down even during long-term factory shutdowns. During the shutdown, it was necessary to supply the required power using an emergency generator, and as part of the preparations, changes to the power wiring routes were made. Additionally, a certain number of personnel were required to manage these arrangements during the shutdown, and improvement measures were being considered. In response, we proposed a product that adds an automatic switching function to our electromagnetic contactor. If either the commercial power or the generator goes off, it automatically switches to the other source. By starting the emergency generator and turning off the commercial power breaker, we were able to significantly reduce the human burden by automatically switching to the emergency power supply. [Case Overview] - Developed a power switching device that automatically switches power during planned factory outages. - Client: A certain automobile manufacturer. - Product implemented: Custom switch TGM-PS. *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe dual system power supply automatically switches between single-phase 100V or 200V up to a maximum of 30A. It has a compact design with a height of 1U (44mm), making it convenient for use with UPS systems. It allows for switching when preparing temporary power during maintenance. It can also be used for automatic switching to commercial power as a backup for inverter operations primarily using solar power.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- In the event of a power outage on the supply side, it can switch to the normal power supply in about 4 milliseconds. - No separate power supply is needed; it will be in standby mode as long as either of the two input systems is supplying power. - It is a self-cooling type, so there is no need to replace fans, and it can be used maintenance-free. - It is equipped with a bypass unit, allowing for the replacement of the switch without affecting the power supply in case of a failure.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe ACSS 200V high-speed power switch is an ideal product for switching between two power sources, such as UPS and commercial power. It is useful for supplying power without interruption to computer systems and building management systems. Please consider it as a measure during power outages or when maintaining the UPS.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationIt is a compact, high-capacity instantaneous excitation DC electromagnetic contactor.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration【Patent Granted】 Next-generation non-interruptible hybrid switching device as an alternative to static switches (STS)! Equipped with enhanced safety and security features, it has already been implemented for data centers. Compared to a semiconductor switch of 400A (daily power consumption of 48 kWh), replacing it with a hybrid switch (ACTS) can reduce annual power loss by 17,520 kWh.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationHX can be used for switching direct current loads (low voltage DC 24V or below) and is ideal for use in tight installation spaces.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTGH is a high-speed power switching device that confirms the synchronization timing for switching from system 1 to system 2 or from system 2 to system 1, with a switching time of less than 5 milliseconds, when two power supply systems are prepared. It incorporates a phase-locked detector.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe TGMEs series is a switch that instantly switches between commercial and backup power sources using electromagnetic coils to supply power to the load during emergencies. It is a versatile product that can be used for a wide range of applications, including switching between commercial power and emergency power sources (such as generators and batteries), as well as switching between distributed power sources represented by cogeneration systems and commercial power.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationMDN is a permanently excited (electrically held) electromagnetic contactor that is optimal for switching direct current loads. We also accommodate special designs such as AC operation.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe TGMVE series is a switch that allows for the setting of off-time and can also switch over with overlap.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe LC is an instant excitation type DC electromagnetic contactor, ideal for switching DC loads of 60V or less.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration【Patent Granted】 Next-generation hybrid switching device with no interruption, replacing static switches (STS)! Equipped with enhanced safety and security features, it has already been implemented for data centers. Compared to a semiconductor switch of 400A (daily power of 48 kWh), replacing it with a hybrid switch (ACTS) can reduce annual power loss by 17,520 kWh.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationAll the devices you use in your daily life cannot be utilized without power. When there is a power outage or when the existing power supply fails, servers, factory production lines, and everything else become unusable. What becomes necessary in such situations is a "high-speed power switch." The power switch developed by our company can immediately switch to the subline power supply in the event of a power outage or power failure.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationACRS is the ideal product for switching between two power sources, such as solar, batteries, generators, and other commercial power sources.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationTank-type engine preheating heater. Starting a generator in cold weather produces black smoke, which can cause pollution issues and disturb neighbors. By preheating the engine in advance, it is gentle on the engine and there is no worry about black smoke. It is easy to install on the engine. It has a built-in lightweight thermostat to control the temperature.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBatteries cannot perform at their best when used in cold conditions. Wrapping them with a heater can improve power. This can lead to an extended product lifespan for the battery.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis is a heater specifically for batteries. It can be placed under the battery for use. In cold environments, battery performance can decrease. It helps to maintain the battery at a temperature of around 27°C, improving performance and extending the product lifespan of the battery. Suitable for MSE batteries, HSE batteries, etc.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationDrilling holes in the engine is difficult. You can simply stick it (requires wiring) to areas you want to heat, such as the oil pan, engine block, and fuel tank. By keeping the fuel warm in cold regions, engine starts become smoother. This helps prevent white and black smoke and contributes to extending the engine's lifespan.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration