We would like to introduce a case where our silent rack, the 'dBP07V(ZR)-7048grtr', was implemented in the laboratory of the Faculty of Information Science and Engineering at Ritsumeikan University. The target equipment is the "SUPER MICRO 7049GP-TRT". "We started using it right away, and it has become so quiet that I couldn't help but laugh; it is very comfortable to use. Thank you very much for this wonderful product," we received in an email. In the email granting permission to publish the comment, it was also mentioned, "It is genuinely quiet." [Case Overview] ■ Target Equipment: SUPER MICRO 7049GP-TRT ■ Implemented Product: dBP07V(ZR)-7048grtr (can be reused for 7049GP-TRT) ■ Installation Location: Ritsumeikan University, Faculty of Information Science and Engineering ■ Laboratory Name: Not disclosed *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe would like to introduce a case where our silent rack, the 'S8.0ZR-24U', was implemented in the laboratory of Toyota Technological Institute. The noise measurement conditions involved placing the measurement microphone 1 meter away from the target equipment at a height of 1 meter. The average value from four measurements taken at the back of the rack was -26.9 dB(A). "We noticed a significant reduction in noise even under maximum load conditions. With this, we can hold meetings and classes in this room. There are no issues with the required performance," was the feedback we received. 【Case Overview】 ■ Target Equipment: VT64 Server XS2-2TI and others ■ Implemented Rack: S8.0ZR-24U ■ System Support: Visual Technology Co., Ltd. ■ Laboratory Name: Confidential *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document summarizes the installation conditions and heat dissipation that affect the results of introducing a silent rack, based on common examples. It includes information on "installation location," as well as "room size" and "rack orientation." This is general information that can be widely utilized, not limited to our products. It will guide you through common issues in server operations and their solutions, as well as related products, so please make use of it. [Contents] ■ Installation location ■ Room size ■ Rack orientation ■ Air conditioning suitability (calculation of air conditioning capacity) ■ Overall room airflow and air conditioner shape *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe "ZITS Heat Diffusion System" is an air-cooled management solution that offers numerous benefits and risk avoidance through the installation of a simple air cooling device, providing an extremely high cost-effectiveness. By diffusing the heat generated in the server room into the adjacent large business area, it distributes the load across the entire area's air conditioning units. Machine cooling ensures that the room temperature (up to 28°C) from the return flow path is always maintained, smartly avoiding localized heat buildup in the server room. Additionally, we conduct on-site diagnostics for heat buildup around server racks and throughout the room. We perform an on-site investigation to identify issues and their solutions, along with predictions of the results. There are no costs involved. Please feel free to consult us. 【Features】 ■ Customized design and on-site installation based on various conditions ■ Resolves temperature issues in the server room ■ No need for additional air conditioning units ■ Soundproofing with no sound leakage *For more details, please refer to the PDF materials or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThis document is an FAQ that summarizes frequently asked questions about the SI Silent Rack. It addresses various service-related questions such as "How do I determine the rack size?" as well as product-related inquiries like "What temperature environment can it be used in?" and "Are there any easy and simple products available?" Our dedicated staff, who are well-versed in the "sound and heat" issues related to silent racks, are here to assist you, so please feel free to reach out for consultation. 【Contents (Excerpt)】 ■ Service-related Q1. What are the delivery methods? Q2. What kind of compatibility checks are conducted? Q3. How do I determine the rack size? Q4. How many machines can be mounted? Q5. What happens if the number of machines increases or decreases? Q6. What about warranties and maintenance contracts? Q7. What are the terms of trade? *For more details, please refer to the PDF document or feel free to contact us.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe will conduct a field survey to identify issues, their solutions, and expected outcomes! There are no costs involved. We will verify the feasibility of solutions for your specific issues and challenges. We will provide technical advice and, if necessary, prepare estimates and proposals in writing. There will be no charges, so please feel free to take advantage of this service.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA quiet type suitable for general offices and small-scale HPC. We widely accommodate the development of individual specifications and custom designs according to the machines and installation locations. We provide reliable implementation results through specialized technology. Each product comes with "product + technical service," which includes machine matching (compatibility investigation). A dedicated representative will individually respond to each project and develop rack specifications. We ensure the achievement of objectives with zero risk for the customer, taking responsibility on the supply side.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA heat dissipation-focused design that matches high-performance computing (HPC) machines with high heat output and GPU-equipped systems. A "specialized" high-spec version with numerous implementations and practical data accumulated in universities and research institutions. All products come with "product + technical service" that includes machine matching (compatibility investigation). A dedicated representative will individually respond to each project and develop rack specifications. We ensure achievement of objectives with zero risk to the customer, taking responsibility from the supply side. 【Features】 - Multi-layer soundproof walls made of multiple materials and a sealed case structure - Equipped with an expansion chamber-type silencer to prevent sound leakage in the ventilation ducts - Forced air cooling with push-pull fans for intake and exhaust (compatible with additional installations and lifespan replacements) - Comprehensive planning and machine matching tailored to the scale of the machines is a mandatory inclusion - Airflow designed to prevent short circuits (recirculation of exhaust heat) is a mandatory inclusion - Sealed wiring ports with no sound or air leakage - Common 19-inch mount standard across all companies. *Free heat dissipation diagnosis for server rooms is also available. *For more details, please contact us or download the PDF materials.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA portable soundproof box for one machine. Despite its simple structure, it offers sound insulation and safety heat dissipation comparable to high-end models. We will develop a dedicated specification for each machine.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe double structure of the inner and outer boxes provides advanced sound insulation with floating contact surfaces. While designed for broadcasting stations and recording studios, it has also been implemented in quiet spaces such as small residential rooms, small offices, reception rooms, and executive offices.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe assembly-type soundproof partition panels allow you to surround existing racks while continuing their operation, effectively addressing noise issues. Equipped with appropriate fan units and large-capacity silencers tailored to the scale of the machines, they achieve a powerful airflow and reliable noise reduction. This low-type stationary unit complies with legal standards, making it suitable for rental buildings where the installation of hyper-partitions is not possible. We provide comprehensive operational management that considers everything from on-site surveys to individual design, installation, and airflow throughout the entire room.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Completely sealed tour case housing - Equipped with the necessary number of forced air cooling fan units - High dust-proof elements use automotive cabin filters - Sealed wiring entry "cable clamper" - Rack size can be customized - Full support for securing airflow and specifications based on machine configuration
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Noise-proof with no sound leakage - No need for additional air conditioning - Energy-saving & simple air cooling system - Stable operation of machines, extended lifespan - Increased focus and work efficiency in a comfortable office!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Noise-proof with no sound leakage - No need for additional air conditioning - Energy-saving & simple air cooling system - Stable operation of the machine, extended lifespan - Increased focus on work and improved efficiency in a comfortable office!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Noise-proof with no sound leakage - No need for additional air conditioning - Energy-saving & simple air cooling system - Stable operation of the machine, extended lifespan - Increased focus on work and improved work efficiency in a comfortable office!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Noise-proof with no sound leakage - No need for additional air conditioning - Energy-saving & simple air cooling system - Stable operation of machines, extended lifespan - Increased focus and work efficiency in a comfortable office!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Noise-proof with no sound leakage - No need for additional air conditioning - Energy-saving & simple air cooling system - Stable operation of machines, extended lifespan - Increased focus and work efficiency in a comfortable office!
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration- Soundproofing enhanced partition - Joints, gaps, and pipe seals - Door stop modification, soundproofing packing - Cooling equipment compatible with horsepower - Machine power supply, air conditioning power supply installation - Fire prevention inspection, adjustment, equipment modification
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration● Silent rack SYSTEM 4.5 according to machine configuration ● Cold air intake box (with built-in active fan) ● Cold air duct ● Cooler connection manifold ● Complete local installation ○ Installation of room air conditioner
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationCustom options for the Silent Rack SYSTEM 4.5. It is a light airflow system that requires no installation and is equipped with an exhaust extension duct. It effectively prevents localized heat buildup due to heat diffusion, making it suitable for small booths separated by office partitions.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA high-end model for one slim tower server. This compact hot version features a specially designed shielding structure and a push-pull fan that provides a double effect of "pushing in + pulling out," condensing high quietness and safety into a small chassis.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe SYSTEM100 silent and soundproof rack features simple functionality that balances basic performance and cost reduction. The rear door employs an expansion chamber-type silencer equivalent to the high-end model SYSTEM4.5, ensuring basic performance. Safety and quietness are highly balanced. The front door adopts a new simple passive structure. As a passive design with a proven track record in the dBP series, it achieves cost reduction. Additionally, the reduction of used parts and a design specifically for mid-sized units contribute to lower costs. This mid-grade silent and soundproof rack is a fusion of noise reduction techniques feedback from high-end models and the development of a simple structure. ⇒【Optimization】 In soundproof racks that seal noise, optimizing the rack specifications to suit each customer is crucial. Insufficient performance compromises safety, while excessive features undermine quietness. The SYSTEM100, fully responsive to compatibility investigations, offers individual technical services free of charge with product sales to guide you to the optimal rack specifications. ⇒【Functionality】 All functions except for the front door are equivalent to the high-end model SYSTEM4.5, incorporating many highly specialized features. ⇒【Custom 14 Colors & CMYK Order Print】
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA convenient fanless type for one machine. It is compatible with both rack and tower types, and can be designed for hubs, switches, and various measuring instruments with different heat dissipation pathways. By adopting a three-layer soundproof sealed enclosure and an expansion chamber type silencer, it significantly reduces noise and ensures safe operation of the machine by partitioning the intake and exhaust pathways to form a one-way flow.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationA smart energy-saving and environmentally friendly system utilizing room temperature air cooling for multiple server racks. We will install server booths and machine rooms using office partitions and dividers. By optimally combining airflow design to prevent heat buildup and silencers to contain noise, we achieve both safe operation and quietness. It is also possible to set up independent booths in large floors or factories. We offer a variety of options including air conditioning equipment, dust prevention, and security.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationHeat dissipation and noise control measures for server rooms. We propose the most suitable and efficient construction methods for our customers to achieve maximum "cost-effectiveness." A quiet and air-cooled server room construction package that enhances effectiveness through a natural and feasible approach.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registration●Noise reduction level Front = -11 dB(A) Back = -13.5 dB(A) ●Width 250 × Height 550 × Depth 850 mm (for server size 220 × 450 × 650) We implement safe and reliable noise control using optimized airflow technology. Please consult us for soundproofing noisy office servers, loud machines, noise control, and air conditioning in server rooms.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationWe offer noise reduction solutions for server racks with coolers. This includes soundproof partitions like the dB-HCP-AP, which significantly reduce noise from ITC-AR1300S and ITC-AR1900S, as well as quiet racks that incorporate the rack-mounted cooler ITC-M1700AS. We provide comprehensive management of optimal piping and thermal airflow. Installation work will be carried out individually based on the specific conditions of each customer’s site.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYSTEM 5.0 has been redesigned with the silencer volume on the rack side. It features a shortened depth and an acrylic window, with a noise reduction of -20dB(A) and a minimum operating sound of 40dB(A) or higher. Due to its large width, the transport route needs to be investigated, and there are limitations on airflow.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationSYSTEM 6.0 has been redesigned with the silencer volume adjusted vertically. This allows for a significant reduction in the installation floor area. An acrylic window can be installed. The decrease in the number of mounting points enables compatibility with machine configurations of medium scale or smaller.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationThe intermediate model SYSTEM60, between the budget version dBP08 and the high-end model SYSTEM4.5, is a specially designed unit equipped with an exhaust fan tailored for a single machine. It secures silencer volume above and below the casing, achieving quietness, safe heat dissipation, and compactness all at once.
Added to bookmarks
Bookmarks listBookmark has been removed
Bookmarks listYou can't add any more bookmarks
By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.
Free membership registrationBuilt-in Apiste Cooler ITC-M1700AS. It enables stable server cooling even in an unstable room temperature environment. The cooler noise is reduced to as low as 43dB(A), allowing for significant cooling advantages without noise complaints.