【Main Specifications】 ■RM-52 Measurement Method: Polarographic Method Electrode Cleaning Method: Glass Bead Cleaning and Electrical Cleaning Measurement Range: 0–2 mg/L ■RM-52PC Measurement Method: Polarographic Method Electrode Cleaning Method: Glass Bead Cleaning and Electrical Cleaning Measurement Range: 0–2 mg/L ■RM-55 Measurement Method: Polarographic Method Electrode Cleaning Method: Glass Bead Cleaning and Electrical Cleaning Measurement Range: 0–1 mg/L, 0–2 mg/L ■Tap water ■Well water (groundwater) ■Hot spring source water ■Pool and bath For more details, please contact our sales representative.
【Other Features】 ■ Two-wavelength photometric method that is resistant to cell and water contamination ■ Measurement of hard water is possible with "DPD reagent for hot springs" ■ Waterproof design that is safe even when splashed with water (IEC standard: equivalent to IP65) ■ Wide LCD digital screen with backlight *For more details, please refer to the PDF document or feel free to contact us. 【Uses】 ■ Legionella measures in bathing facilities ■ Chlorine concentration management in food factories, chemical plants, etc. ■ Water quality checks for tap water and water storage tanks ■ Water quality checks for pools and hot springs *For more details, please refer to the PDF document or feel free to contact us.
【Main Specifications】 Polarographic High Concentration Residual Chlorine Meter (HM-1000 Series) Measurement Target: Free residual chlorine in water (the quality of the source water should be similar to tap water) Measurement Method: 3-electrode polarographic method Electrode Cleaning Method: Glass bead cleaning and electrical cleaning Recommended Measurement Range: 0–5 mg/L, 5–50 mg/L, 20–200 mg/L Response Speed: Within 10 seconds from the holder inlet (90% response) Measurement Water Conditions: (1) Temperature: 0–45°C (no freezing) (2) Flow Rate: HM-1000-HB□/0.8–1.2 L/min HM-1000-HC□/1.2–4.5 L/min (3) Pressure: HM-1000-HB□/0.1–0.3 MPa HM-1000-HC□/below 0.3 MPa (4) pH Value: 6.0–10 pH (constant) ■ Monitoring of CIP disinfectant water ■ Making of disinfectant water for push water ■ Measurement of weakly acidic hypochlorous water ■ Monitoring and making of disinfectant water for rinsing ■ Monitoring of water for pasta, warmers, and coolers For more details, please contact your sales representative.
---

---

--- ---
  1. 代表製品
    Residual Chlorine Meter "RM"Residual Chlorine Meter "RM"
    概要
    【Main Specifications】 ■RM-52 Measurement Method: Polarographic Method Electrode Cleaning Method: Glass Bead Cleaning and Electrical Cleaning Measurement Range: 0–2 mg/L ■RM-52PC Measurement Method: Polarographic Method Electrode Cleaning Method: Glass Bead Cleaning and Electrical Cleaning Measurement Range: 0–2 mg/L ■RM-55 Measurement Method: Polarographic Method Electrode Cleaning Method: Glass Bead Cleaning and Electrical Cleaning Measurement Range: 0–1 mg/L, 0–2 mg/L
    用途/実績例
    ■Tap water ■Well water (groundwater) ■Hot spring source water ■Pool and bath For more details, please contact our sales representative.
    Residual Chlorine Meter 'Accurate Measurement with One Finger! Digital Residual Chlorine Tester DCT'Residual Chlorine Meter 'Accurate Measurement with One Finger! Digital Residual Chlorine Tester DCT'
    概要
    【Other Features】 ■ Two-wavelength photometric method that is resistant to cell and water contamination ■ Measurement of hard water is possible with "DPD reagent for hot springs" ■ Waterproof design that is safe even when splashed with water (IEC standard: equivalent to IP65) ■ Wide LCD digital screen with backlight *For more details, please refer to the PDF document or feel free to contact us.
    用途/実績例
    【Uses】 ■ Legionella measures in bathing facilities ■ Chlorine concentration management in food factories, chemical plants, etc. ■ Water quality checks for tap water and water storage tanks ■ Water quality checks for pools and hot springs *For more details, please refer to the PDF document or feel free to contact us.
    Residual Chlorine Meter "HACCP Compliant for Food Factories, Maximum 200 mg/L! HM"Residual Chlorine Meter "HACCP Compliant for Food Factories, Maximum 200 mg/L! HM"
    概要
    【Main Specifications】 Polarographic High Concentration Residual Chlorine Meter (HM-1000 Series) Measurement Target: Free residual chlorine in water (the quality of the source water should be similar to tap water) Measurement Method: 3-electrode polarographic method Electrode Cleaning Method: Glass bead cleaning and electrical cleaning Recommended Measurement Range: 0–5 mg/L, 5–50 mg/L, 20–200 mg/L Response Speed: Within 10 seconds from the holder inlet (90% response) Measurement Water Conditions: (1) Temperature: 0–45°C (no freezing) (2) Flow Rate: HM-1000-HB□/0.8–1.2 L/min HM-1000-HC□/1.2–4.5 L/min (3) Pressure: HM-1000-HB□/0.1–0.3 MPa HM-1000-HC□/below 0.3 MPa (4) pH Value: 6.0–10 pH (constant)
    用途/実績例
    ■ Monitoring of CIP disinfectant water ■ Making of disinfectant water for push water ■ Measurement of weakly acidic hypochlorous water ■ Monitoring and making of disinfectant water for rinsing ■ Monitoring of water for pasta, warmers, and coolers For more details, please contact your sales representative.