Product Image, Product Name, Price Range overview Application/Performance example
●Up to 4 branches are possible within 1 unit. ●Can be selected for either rail assembly or shaft assembly. (Shaft assembly can be mounted with 2-point or 4-point fixation.) ●Can be easily attached and detached from the DIN rail. ●The cross groove on the bolt head allows for temporary tightening with a screwdriver. Branch wiring applications for electric wires, etc.
● Rated insulation voltage: 600V ● Rated current: 30A ● Maximum connected wire: 5.5mm² ● Screw size: M4X8.5 ● Dielectric strength: AC2500V/1 minute ● Lightning impulse: ±6kV/3 times per pole (1.2/50μs) ● Operating ambient temperature: -20 to 50℃ ● Storage temperature: -40 to 75℃ ● Operating conditions (elevation): below 2000m Control panel, distribution panel, etc.
● Achieving Compactness - Since terminals are integrated inside the unit, it can be installed compactly. ● Two Types of Assembly Available - Both rail assembly and shaft assembly are possible, allowing for selection based on application. ● Increased Safety During Crimping Operations - Installation using connecting pins for spencers is also possible, enhancing safety during crimping operations. ● Large Covers Also Available - Covers for reinforcing the protection of crimped areas are also available for selection. Capable of high-capacity power supply.
---

---

---
  1. Featured Products
    Branch terminal block (TX-□DF type)Branch terminal block (TX-□DF type)
    overview
    ●Up to 4 branches are possible within 1 unit. ●Can be selected for either rail assembly or shaft assembly. (Shaft assembly can be mounted with 2-point or 4-point fixation.) ●Can be easily attached and detached from the DIN rail. ●The cross groove on the bolt head allows for temporary tightening with a screwdriver.
    Application/Performance example
    Branch wiring applications for electric wires, etc.
    Terminal block (AFD type)Terminal block (AFD type)
    overview
    ● Rated insulation voltage: 600V ● Rated current: 30A ● Maximum connected wire: 5.5mm² ● Screw size: M4X8.5 ● Dielectric strength: AC2500V/1 minute ● Lightning impulse: ±6kV/3 times per pole (1.2/50μs) ● Operating ambient temperature: -20 to 50℃ ● Storage temperature: -40 to 75℃ ● Operating conditions (elevation): below 2000m
    Application/Performance example
    Control panel, distribution panel, etc.
    Terminal block (TX□-325F type)Terminal block (TX□-325F type)
    overview
    ● Achieving Compactness - Since terminals are integrated inside the unit, it can be installed compactly. ● Two Types of Assembly Available - Both rail assembly and shaft assembly are possible, allowing for selection based on application. ● Increased Safety During Crimping Operations - Installation using connecting pins for spencers is also possible, enhancing safety during crimping operations. ● Large Covers Also Available - Covers for reinforcing the protection of crimped areas are also available for selection.
    Application/Performance example
    Capable of high-capacity power supply.