[3 Models Common] Operating Temperature: -40 to +80℃ Dimensions: φ26×225mm Maximum Terminal Diameter: φ5mm (20AWG-0.5mm²) [HD9008.T7AC] Power Supply: DC10 to 30V Measurement Range: -40 to +80℃ Output Scaling: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): <15 seconds (when filter (P1) is installed) Output Signal: DC4 to 20mA Load Resistance: RLmax = (Vdc - 10) / 22mA Maximum Cable Length: 200m [HD9008.T7S] Power Supply: DC5 to 30V Measurement Range: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): 15 seconds (without filter) Output Signal: RS485 Modbus-RTU Maximum Cable Length: Depends on baud rate and line number [HD9008.03] Power Supply: No power supply required Measurement Range/Output Scaling: JISC1604:2013, dependent on receiver side, scaling required Accuracy: JISC1604:2013, Class A compliant Response Time (t₆₃): 15 seconds (without filter) Output Signal: Pt100 resistance value | Ideal for indoors as well as outdoors, such as weather stations. | ||
■Input Sensor: Thermocouple K, J, T, N Connection: 2-wire Measurement Range (Thermocouple): K: -200 to +1200℃, T: -200 to +300℃, J: -200 to +800℃, N: -200 to +1200℃ Linearization: EN60584-1-2, ASTM E230-ANSI (MC96-1) Standard Setting Range: Tc=K, Range=0 to 1000℃ Minimum Measurement Span: 50℃ Conversion Speed: 2 times/second Accuracy: ±0.04% FS ±0.04% rdg or 0.5℃ (whichever is greater) Cold Junction Temperature Range: 0 to 70℃ ■Output Output Type: 4-20mA (or 20-4mA), 22mA output for sensor connection failure or abnormality in 2-wire connection Resolution: [HD978TR1] 4μA [HD978TR2] 4μV display, 0.1℃: Temperature <200℃, 1℃: Temperature >200℃ Power Supply: DC9-30V (with reverse polarity protection) Effect of Power Supply Voltage Fluctuation: 0.4μA/V Load Resistance: RLmax =(Vdc-9)/0.022 RLmax = 680Ω at Vdc = DC24V Warm-up Time: 2 minutes Operating Temperature: 0 to 70℃ Storage Temperature: -40 to +80℃ | Industrial process control Power and energy management Temperature monitoring of machinery and engines, etc. | ||
[HD9008TRR/HD9009TRR Common] Humidity measurement range: 0 to 100% RH Humidity accuracy: At 15 to 35℃: ±1.5% (0 to 90% RH) / ±2% (humidity range other than the above) Outside the above temperature range: ±(1.5 + 1.5% rdg)% Temperature measurement range: -40 to +80℃ Temperature accuracy: ±0.2℃ ±0.15% rdg [HD9008TRR] Power supply: DC 10 to 30V (4 to 20mA) Humidity output signal: 0% RH = 4.0mA 100% RH = 20.0mA Humidity load resistance: RLmax = (Vdc - 10) / 22mA Temperature output signal: -40℃ = 4.0mA +80℃ = 20.0mA Temperature load resistance: RLmax = (Vdc - 10) / 22mA Maximum cable length: 200m [HD9009TRR] Power supply: DC 5 to 35V (2mA) Humidity output signal: 0% RH = DC 0.00V 100% RH = DC 1.00V Humidity load resistance: Rinmin = 10kΩ Temperature output signal: -40℃ = DC 0.00V +80℃ = DC 1.00V Temperature load resistance: Rinmin = 10kΩ Maximum cable length: 10m | Ideal for indoors as well as outdoors, such as weather stations. | ||
---
--- |
--- |
-
- Featured Products
-
Temperature Transmitter / HD9008.T7AC_T7S_03
- overview
- [3 Models Common] Operating Temperature: -40 to +80℃ Dimensions: φ26×225mm Maximum Terminal Diameter: φ5mm (20AWG-0.5mm²) [HD9008.T7AC] Power Supply: DC10 to 30V Measurement Range: -40 to +80℃ Output Scaling: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): <15 seconds (when filter (P1) is installed) Output Signal: DC4 to 20mA Load Resistance: RLmax = (Vdc - 10) / 22mA Maximum Cable Length: 200m [HD9008.T7S] Power Supply: DC5 to 30V Measurement Range: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): 15 seconds (without filter) Output Signal: RS485 Modbus-RTU Maximum Cable Length: Depends on baud rate and line number [HD9008.03] Power Supply: No power supply required Measurement Range/Output Scaling: JISC1604:2013, dependent on receiver side, scaling required Accuracy: JISC1604:2013, Class A compliant Response Time (t₆₃): 15 seconds (without filter) Output Signal: Pt100 resistance value
- Application/Performance example
- Ideal for indoors as well as outdoors, such as weather stations.
Thermocouple Temperature Transmitter / HD978TR1/TR2
- overview
- ■Input Sensor: Thermocouple K, J, T, N Connection: 2-wire Measurement Range (Thermocouple): K: -200 to +1200℃, T: -200 to +300℃, J: -200 to +800℃, N: -200 to +1200℃ Linearization: EN60584-1-2, ASTM E230-ANSI (MC96-1) Standard Setting Range: Tc=K, Range=0 to 1000℃ Minimum Measurement Span: 50℃ Conversion Speed: 2 times/second Accuracy: ±0.04% FS ±0.04% rdg or 0.5℃ (whichever is greater) Cold Junction Temperature Range: 0 to 70℃ ■Output Output Type: 4-20mA (or 20-4mA), 22mA output for sensor connection failure or abnormality in 2-wire connection Resolution: [HD978TR1] 4μA [HD978TR2] 4μV display, 0.1℃: Temperature <200℃, 1℃: Temperature >200℃ Power Supply: DC9-30V (with reverse polarity protection) Effect of Power Supply Voltage Fluctuation: 0.4μA/V Load Resistance: RLmax =(Vdc-9)/0.022 RLmax = 680Ω at Vdc = DC24V Warm-up Time: 2 minutes Operating Temperature: 0 to 70℃ Storage Temperature: -40 to +80℃
- Application/Performance example
- Industrial process control Power and energy management Temperature monitoring of machinery and engines, etc.
Temperature and Humidity Transmitter / HD9008TRR
- overview
- [HD9008TRR/HD9009TRR Common] Humidity measurement range: 0 to 100% RH Humidity accuracy: At 15 to 35℃: ±1.5% (0 to 90% RH) / ±2% (humidity range other than the above) Outside the above temperature range: ±(1.5 + 1.5% rdg)% Temperature measurement range: -40 to +80℃ Temperature accuracy: ±0.2℃ ±0.15% rdg [HD9008TRR] Power supply: DC 10 to 30V (4 to 20mA) Humidity output signal: 0% RH = 4.0mA 100% RH = 20.0mA Humidity load resistance: RLmax = (Vdc - 10) / 22mA Temperature output signal: -40℃ = 4.0mA +80℃ = 20.0mA Temperature load resistance: RLmax = (Vdc - 10) / 22mA Maximum cable length: 200m [HD9009TRR] Power supply: DC 5 to 35V (2mA) Humidity output signal: 0% RH = DC 0.00V 100% RH = DC 1.00V Humidity load resistance: Rinmin = 10kΩ Temperature output signal: -40℃ = DC 0.00V +80℃ = DC 1.00V Temperature load resistance: Rinmin = 10kΩ Maximum cable length: 10m
- Application/Performance example
- Ideal for indoors as well as outdoors, such as weather stations.
-