We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Transmitter.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Transmitter - Company Ranking(34 companyies in total)

Last Updated: Aggregation Period:Jul 23, 2025〜Aug 19, 2025
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
[3 Models Common] Operating Temperature: -40 to +80℃ Dimensions: φ26×225mm Maximum Terminal Diameter: φ5mm (20AWG-0.5mm²) [HD9008.T7AC] Power Supply: DC10 to 30V Measurement Range: -40 to +80℃ Output Scaling: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): <15 seconds (when filter (P1) is installed) Output Signal: DC4 to 20mA Load Resistance: RLmax = (Vdc - 10) / 22mA Maximum Cable Length: 200m [HD9008.T7S] Power Supply: DC5 to 30V Measurement Range: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): 15 seconds (without filter) Output Signal: RS485 Modbus-RTU Maximum Cable Length: Depends on baud rate and line number [HD9008.03] Power Supply: No power supply required Measurement Range/Output Scaling: JISC1604:2013, dependent on receiver side, scaling required Accuracy: JISC1604:2013, Class A compliant Response Time (t₆₃): 15 seconds (without filter) Output Signal: Pt100 resistance value Ideal for indoors as well as outdoors, such as weather stations.
■Input Sensor: Thermocouple K, J, T, N Connection: 2-wire Measurement Range (Thermocouple): K: -200 to +1200℃, T: -200 to +300℃, J: -200 to +800℃, N: -200 to +1200℃ Linearization: EN60584-1-2, ASTM E230-ANSI (MC96-1) Standard Setting Range: Tc=K, Range=0 to 1000℃ Minimum Measurement Span: 50℃ Conversion Speed: 2 times/second Accuracy: ±0.04% FS ±0.04% rdg or 0.5℃ (whichever is greater) Cold Junction Temperature Range: 0 to 70℃ ■Output Output Type: 4-20mA (or 20-4mA), 22mA output for sensor connection failure or abnormality in 2-wire connection Resolution: [HD978TR1] 4μA [HD978TR2] 4μV display, 0.1℃: Temperature <200℃, 1℃: Temperature >200℃ Power Supply: DC9-30V (with reverse polarity protection) Effect of Power Supply Voltage Fluctuation: 0.4μA/V Load Resistance: RLmax =(Vdc-9)/0.022 RLmax = 680Ω at Vdc = DC24V Warm-up Time: 2 minutes Operating Temperature: 0 to 70℃ Storage Temperature: -40 to +80℃ Industrial process control Power and energy management Temperature monitoring of machinery and engines, etc.
[HD9008TRR/HD9009TRR Common] Humidity measurement range: 0 to 100% RH Humidity accuracy: At 15 to 35℃: ±1.5% (0 to 90% RH) / ±2% (humidity range other than the above) Outside the above temperature range: ±(1.5 + 1.5% rdg)% Temperature measurement range: -40 to +80℃ Temperature accuracy: ±0.2℃ ±0.15% rdg [HD9008TRR] Power supply: DC 10 to 30V (4 to 20mA) Humidity output signal: 0% RH = 4.0mA 100% RH = 20.0mA Humidity load resistance: RLmax = (Vdc - 10) / 22mA Temperature output signal: -40℃ = 4.0mA +80℃ = 20.0mA Temperature load resistance: RLmax = (Vdc - 10) / 22mA Maximum cable length: 200m [HD9009TRR] Power supply: DC 5 to 35V (2mA) Humidity output signal: 0% RH = DC 0.00V 100% RH = DC 1.00V Humidity load resistance: Rinmin = 10kΩ Temperature output signal: -40℃ = DC 0.00V +80℃ = DC 1.00V Temperature load resistance: Rinmin = 10kΩ Maximum cable length: 10m Ideal for indoors as well as outdoors, such as weather stations.
---

---

---
  1. Featured Products
    Temperature Transmitter / HD9008.T7AC_T7S_03Temperature Transmitter / HD9008.T7AC_T7S_03
    overview
    [3 Models Common] Operating Temperature: -40 to +80℃ Dimensions: φ26×225mm Maximum Terminal Diameter: φ5mm (20AWG-0.5mm²) [HD9008.T7AC] Power Supply: DC10 to 30V Measurement Range: -40 to +80℃ Output Scaling: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): <15 seconds (when filter (P1) is installed) Output Signal: DC4 to 20mA Load Resistance: RLmax = (Vdc - 10) / 22mA Maximum Cable Length: 200m [HD9008.T7S] Power Supply: DC5 to 30V Measurement Range: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): 15 seconds (without filter) Output Signal: RS485 Modbus-RTU Maximum Cable Length: Depends on baud rate and line number [HD9008.03] Power Supply: No power supply required Measurement Range/Output Scaling: JISC1604:2013, dependent on receiver side, scaling required Accuracy: JISC1604:2013, Class A compliant Response Time (t₆₃): 15 seconds (without filter) Output Signal: Pt100 resistance value
    Application/Performance example
    Ideal for indoors as well as outdoors, such as weather stations.
    Thermocouple Temperature Transmitter / HD978TR1/TR2Thermocouple Temperature Transmitter / HD978TR1/TR2
    overview
    ■Input Sensor: Thermocouple K, J, T, N Connection: 2-wire Measurement Range (Thermocouple): K: -200 to +1200℃, T: -200 to +300℃, J: -200 to +800℃, N: -200 to +1200℃ Linearization: EN60584-1-2, ASTM E230-ANSI (MC96-1) Standard Setting Range: Tc=K, Range=0 to 1000℃ Minimum Measurement Span: 50℃ Conversion Speed: 2 times/second Accuracy: ±0.04% FS ±0.04% rdg or 0.5℃ (whichever is greater) Cold Junction Temperature Range: 0 to 70℃ ■Output Output Type: 4-20mA (or 20-4mA), 22mA output for sensor connection failure or abnormality in 2-wire connection Resolution: [HD978TR1] 4μA [HD978TR2] 4μV display, 0.1℃: Temperature <200℃, 1℃: Temperature >200℃ Power Supply: DC9-30V (with reverse polarity protection) Effect of Power Supply Voltage Fluctuation: 0.4μA/V Load Resistance: RLmax =(Vdc-9)/0.022 RLmax = 680Ω at Vdc = DC24V Warm-up Time: 2 minutes Operating Temperature: 0 to 70℃ Storage Temperature: -40 to +80℃
    Application/Performance example
    Industrial process control Power and energy management Temperature monitoring of machinery and engines, etc.
    Temperature and Humidity Transmitter / HD9008TRRTemperature and Humidity Transmitter / HD9008TRR
    overview
    [HD9008TRR/HD9009TRR Common] Humidity measurement range: 0 to 100% RH Humidity accuracy: At 15 to 35℃: ±1.5% (0 to 90% RH) / ±2% (humidity range other than the above) Outside the above temperature range: ±(1.5 + 1.5% rdg)% Temperature measurement range: -40 to +80℃ Temperature accuracy: ±0.2℃ ±0.15% rdg [HD9008TRR] Power supply: DC 10 to 30V (4 to 20mA) Humidity output signal: 0% RH = 4.0mA 100% RH = 20.0mA Humidity load resistance: RLmax = (Vdc - 10) / 22mA Temperature output signal: -40℃ = 4.0mA +80℃ = 20.0mA Temperature load resistance: RLmax = (Vdc - 10) / 22mA Maximum cable length: 200m [HD9009TRR] Power supply: DC 5 to 35V (2mA) Humidity output signal: 0% RH = DC 0.00V 100% RH = DC 1.00V Humidity load resistance: Rinmin = 10kΩ Temperature output signal: -40℃ = DC 0.00V +80℃ = DC 1.00V Temperature load resistance: Rinmin = 10kΩ Maximum cable length: 10m
    Application/Performance example
    Ideal for indoors as well as outdoors, such as weather stations.