We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Temperature Transmitters.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Temperature Transmitters - Company Ranking(1 companyies in total)

Last Updated: Aggregation Period:Jul 23, 2025〜Aug 19, 2025
This ranking is based on the number of page views on our site.

Company Name Featured Products
Product Image, Product Name, Price Range overview Application/Performance example
■Input Sensor: Thermocouple K, J, T, N Connection: 2-wire Measurement Range (Thermocouple): K: -200 to +1200℃, T: -200 to +300℃, J: -200 to +800℃, N: -200 to +1200℃ Linearization: EN60584-1-2, ASTM E230-ANSI (MC96-1) Standard Setting Range: Tc=K, Range=0 to 1000℃ Minimum Measurement Span: 50℃ Conversion Speed: 2 times/second Accuracy: ±0.04% FS ±0.04% rdg or 0.5℃ (whichever is greater) Cold Junction Temperature Range: 0 to 70℃ ■Output Output Type: 4-20mA (or 20-4mA), 22mA output for sensor connection failure or abnormality in 2-wire connection Resolution: [HD978TR1] 4μA [HD978TR2] 4μV display, 0.1℃: Temperature <200℃, 1℃: Temperature >200℃ Power Supply: DC9-30V (with reverse polarity protection) Effect of Power Supply Voltage Fluctuation: 0.4μA/V Load Resistance: RLmax =(Vdc-9)/0.022 RLmax = 680Ω at Vdc = DC24V Warm-up Time: 2 minutes Operating Temperature: 0 to 70℃ Storage Temperature: -40 to +80℃ Industrial process control Power and energy management Temperature monitoring of machinery and engines, etc.
[3 Models Common] Operating Temperature: -40 to +80℃ Dimensions: φ26×225mm Maximum Terminal Diameter: φ5mm (20AWG-0.5mm²) [HD9008.T7AC] Power Supply: DC10 to 30V Measurement Range: -40 to +80℃ Output Scaling: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): <15 seconds (when filter (P1) is installed) Output Signal: DC4 to 20mA Load Resistance: RLmax = (Vdc - 10) / 22mA Maximum Cable Length: 200m [HD9008.T7S] Power Supply: DC5 to 30V Measurement Range: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): 15 seconds (without filter) Output Signal: RS485 Modbus-RTU Maximum Cable Length: Depends on baud rate and line number [HD9008.03] Power Supply: No power supply required Measurement Range/Output Scaling: JISC1604:2013, dependent on receiver side, scaling required Accuracy: JISC1604:2013, Class A compliant Response Time (t₆₃): 15 seconds (without filter) Output Signal: Pt100 resistance value Ideal for indoors as well as outdoors, such as weather stations.
● Temperature ○ Measurement Range [Standard Range] -20 to +80℃ [Extended Range] -40 to +150℃ ○ Accuracy [Standard Range] ±0.3℃ (0 to 70℃), ±0.4℃ (-20 to 0℃, 70 to 80℃) [Extended Range] ±0.3℃ ● Relative Humidity ○ Measurement Range: 0 to 100% RH ○ Accuracy [Temperature Range 15 to 35℃] ±1.5% RH (0 to 90% range) ±2.0% RH (outside the above range) [Other Temperature Ranges] ±(1.5 + 1.5% rdg) % RH ● Dew Point ○ Measurement Range: -20 to +80℃ DP ○ Accuracy *Refer to Catalog Table 1 ● Output *Refer to Catalog Table 2 ● Power Supply HD48□□ Series: DC 18 to 40V or AC 24V ±10%, Modbus output models: DC 12 to 30V HD49□□ Series: DC 12 to 40V ● Current Consumption [HD48□□ Series] (at 24V) Voltage output models: 4mA Current output models: 4mA when output is open, 20mA at 12mA output RS485 output models: 2mA [HD49□□ Series] 4 to 20mA, 22mA during error output ● Connection Electrical connection: Terminal connection, Cable gland PG16 Designed for controlling temperature and relative humidity in the HVAC and BEMS fields, it can be used in various industries and civilian applications such as pharmaceutical factories, museums, clean rooms, ventilation ducts, kitchens and dining halls, auditoriums, sports gyms, and farm facilities.
---

---

---
  1. Featured Products
    Thermocouple Temperature Transmitter / HD978TR1/TR2Thermocouple Temperature Transmitter / HD978TR1/TR2
    overview
    ■Input Sensor: Thermocouple K, J, T, N Connection: 2-wire Measurement Range (Thermocouple): K: -200 to +1200℃, T: -200 to +300℃, J: -200 to +800℃, N: -200 to +1200℃ Linearization: EN60584-1-2, ASTM E230-ANSI (MC96-1) Standard Setting Range: Tc=K, Range=0 to 1000℃ Minimum Measurement Span: 50℃ Conversion Speed: 2 times/second Accuracy: ±0.04% FS ±0.04% rdg or 0.5℃ (whichever is greater) Cold Junction Temperature Range: 0 to 70℃ ■Output Output Type: 4-20mA (or 20-4mA), 22mA output for sensor connection failure or abnormality in 2-wire connection Resolution: [HD978TR1] 4μA [HD978TR2] 4μV display, 0.1℃: Temperature <200℃, 1℃: Temperature >200℃ Power Supply: DC9-30V (with reverse polarity protection) Effect of Power Supply Voltage Fluctuation: 0.4μA/V Load Resistance: RLmax =(Vdc-9)/0.022 RLmax = 680Ω at Vdc = DC24V Warm-up Time: 2 minutes Operating Temperature: 0 to 70℃ Storage Temperature: -40 to +80℃
    Application/Performance example
    Industrial process control Power and energy management Temperature monitoring of machinery and engines, etc.
    Temperature Transmitter / HD9008.T7AC_T7S_03Temperature Transmitter / HD9008.T7AC_T7S_03
    overview
    [3 Models Common] Operating Temperature: -40 to +80℃ Dimensions: φ26×225mm Maximum Terminal Diameter: φ5mm (20AWG-0.5mm²) [HD9008.T7AC] Power Supply: DC10 to 30V Measurement Range: -40 to +80℃ Output Scaling: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): <15 seconds (when filter (P1) is installed) Output Signal: DC4 to 20mA Load Resistance: RLmax = (Vdc - 10) / 22mA Maximum Cable Length: 200m [HD9008.T7S] Power Supply: DC5 to 30V Measurement Range: -40 to +80℃ Accuracy: ±0.2℃ ±0.15% rdg Response Time (t₆₃): 15 seconds (without filter) Output Signal: RS485 Modbus-RTU Maximum Cable Length: Depends on baud rate and line number [HD9008.03] Power Supply: No power supply required Measurement Range/Output Scaling: JISC1604:2013, dependent on receiver side, scaling required Accuracy: JISC1604:2013, Class A compliant Response Time (t₆₃): 15 seconds (without filter) Output Signal: Pt100 resistance value
    Application/Performance example
    Ideal for indoors as well as outdoors, such as weather stations.
    Humidity, temperature, and dew point temperature transmitter / HD48_HD49Humidity, temperature, and dew point temperature transmitter / HD48_HD49
    overview
    ● Temperature ○ Measurement Range [Standard Range] -20 to +80℃ [Extended Range] -40 to +150℃ ○ Accuracy [Standard Range] ±0.3℃ (0 to 70℃), ±0.4℃ (-20 to 0℃, 70 to 80℃) [Extended Range] ±0.3℃ ● Relative Humidity ○ Measurement Range: 0 to 100% RH ○ Accuracy [Temperature Range 15 to 35℃] ±1.5% RH (0 to 90% range) ±2.0% RH (outside the above range) [Other Temperature Ranges] ±(1.5 + 1.5% rdg) % RH ● Dew Point ○ Measurement Range: -20 to +80℃ DP ○ Accuracy *Refer to Catalog Table 1 ● Output *Refer to Catalog Table 2 ● Power Supply HD48□□ Series: DC 18 to 40V or AC 24V ±10%, Modbus output models: DC 12 to 30V HD49□□ Series: DC 12 to 40V ● Current Consumption [HD48□□ Series] (at 24V) Voltage output models: 4mA Current output models: 4mA when output is open, 20mA at 12mA output RS485 output models: 2mA [HD49□□ Series] 4 to 20mA, 22mA during error output ● Connection Electrical connection: Terminal connection, Cable gland PG16
    Application/Performance example
    Designed for controlling temperature and relative humidity in the HVAC and BEMS fields, it can be used in various industries and civilian applications such as pharmaceutical factories, museums, clean rooms, ventilation ducts, kitchens and dining halls, auditoriums, sports gyms, and farm facilities.