Thermocouple Thermometer - Company Ranking(4 companyies in total)
Last Updated: Aggregation Period:Jul 09, 2025〜Aug 05, 2025
This ranking is based on the number of page views on our site.
Display Company Information
Company Name | Featured Products | ||
---|---|---|---|
Product Image, Product Name, Price Range | overview | Application/Performance example | |
■Temperature Measurement of the Thermometer Body Thermocouple Type (Measurement Range) and Accuracy: K (-200 to +1370℃): ±0.1℃: ≤600℃, ±0.2℃: >600℃ J (-100 to +750℃): ±0.05℃: ≤400℃, ±0.1℃: >400℃ T (-200 to +400℃): ±0.1℃ N (-200 to +1300℃): ±0.1℃: ≤600℃, ±0.2℃: >600℃ R (200 to 1480℃): ±0.25℃ S (200 to 1480℃): ±0.3℃ B (200 to 1800℃): ±0.35℃ E (-200 to +750℃): ±0.1℃: ≤300℃, ±0.15℃: >300℃ Resolution: 0.05℃: ≤199.95℃, 0.1℃: 200℃ to full scale *The stated accuracy pertains only to the thermometer body and does not include errors from the thermocouple or cold junction reference sensor (accuracy ±0.2℃). Temperature Drift: 0.02%/℃ (at 20℃) Drift after 1 year: 0.1℃/year ■Thermometer Body Dimensions (L×W×H): 185×90×40mm (excluding protrusions) Weight: Approximately 470g (including battery) Housing Material: ABS resin, rubber | High-precision temperature measurement compatible with various thermocouples. | ||
■Temperature Measurement of the Thermometer Body Thermocouple Type (Measurement Range) and Accuracy: K (-200 to +1370℃): ±0.1℃: ≤600℃, ±0.2℃: >600℃ J (-100 to +750℃): ±0.1℃: ≤400℃, ±0.2℃: >400℃ T (-200 to +400℃): ±0.1℃ E (-200 to +750℃): ±0.1℃: ≤300℃, ±0.2℃: >300℃ Resolution: 0.1℃ *The stated accuracy only pertains to the thermometer body and does not include errors from the thermocouple or cold junction reference sensor (accuracy ±0.2℃). Temperature Drift: 0.02%/℃ (at 20℃) Drift after 1 year: 0.1℃/year ■Thermometer Body Dimensions (L×W×H): 140×88×38mm Weight: Approximately 160g (including batteries) Housing Material: ABS Resin Display: 2×4½ digits and display symbols, visible area dimensions 52×42mm ■Operating Conditions Operating Temperature: -5 to +50℃ Storage Temperature: -25 to +65℃ Operating Humidity: 0 to 90% RH, without condensation Protection Rating: IP67 ■Power Supply Batteries: 1.5V AA batteries × 3 | High-precision temperature measurement with two channels compatible with various thermocouples. | ||
■Temperature Measurement of the Thermometer Body ●RTD Sensor Pt100 Measurement Range: -200 to +650℃ Pt1000 Measurement Range: -200 to +650℃ Resolution: 0.1℃ Accuracy: ±0.05℃ Drift after 1 year: 0.1℃/year ■Thermocouple ●Thermocouple Types (Measurement Range) and Accuracy K Thermocouple (-200 to +1370℃): ±0.1℃ (up to 600℃), ±0.2℃ (beyond 600℃) J Thermocouple (-100 to +750℃): ±0.1℃ (up to 400℃), ±0.2℃ (beyond 400℃) T Thermocouple (-200 to +400℃): ±0.1℃ N Thermocouple (-200 to +1300℃): ±0.1℃ (up to 600℃), ±0.2℃ (beyond 600℃) E Thermocouple (-200 to +750℃): ±0.1℃ (up to 300℃), ±0.2℃ (beyond 300℃) Resolution: 0.1℃ Temperature Drift (at 20℃): 0.02%/℃ Drift after 1 year: 0.1℃/year *The stated accuracy only pertains to the thermometer body. Errors due to the thermocouple or cold junction reference sensor (accuracy ±0.2℃) are not included. ■Operating Conditions Operating Temperature: -5 to +50℃ Storage Temperature: -25 to +65℃ | Temperature measurement tailored to the application allows for extensive and highly accurate temperature analysis. | ||
---
--- |
--- |
-
- Featured Products
-
Thermocouple thermometer HD2108.1/HD2108.2
- overview
- ■Temperature Measurement of the Thermometer Body Thermocouple Type (Measurement Range) and Accuracy: K (-200 to +1370℃): ±0.1℃: ≤600℃, ±0.2℃: >600℃ J (-100 to +750℃): ±0.05℃: ≤400℃, ±0.1℃: >400℃ T (-200 to +400℃): ±0.1℃ N (-200 to +1300℃): ±0.1℃: ≤600℃, ±0.2℃: >600℃ R (200 to 1480℃): ±0.25℃ S (200 to 1480℃): ±0.3℃ B (200 to 1800℃): ±0.35℃ E (-200 to +750℃): ±0.1℃: ≤300℃, ±0.15℃: >300℃ Resolution: 0.05℃: ≤199.95℃, 0.1℃: 200℃ to full scale *The stated accuracy pertains only to the thermometer body and does not include errors from the thermocouple or cold junction reference sensor (accuracy ±0.2℃). Temperature Drift: 0.02%/℃ (at 20℃) Drift after 1 year: 0.1℃/year ■Thermometer Body Dimensions (L×W×H): 185×90×40mm (excluding protrusions) Weight: Approximately 470g (including battery) Housing Material: ABS resin, rubber
- Application/Performance example
- High-precision temperature measurement compatible with various thermocouples.
2-channel thermocouple thermometer / HD2328.0
- overview
- ■Temperature Measurement of the Thermometer Body Thermocouple Type (Measurement Range) and Accuracy: K (-200 to +1370℃): ±0.1℃: ≤600℃, ±0.2℃: >600℃ J (-100 to +750℃): ±0.1℃: ≤400℃, ±0.2℃: >400℃ T (-200 to +400℃): ±0.1℃ E (-200 to +750℃): ±0.1℃: ≤300℃, ±0.2℃: >300℃ Resolution: 0.1℃ *The stated accuracy only pertains to the thermometer body and does not include errors from the thermocouple or cold junction reference sensor (accuracy ±0.2℃). Temperature Drift: 0.02%/℃ (at 20℃) Drift after 1 year: 0.1℃/year ■Thermometer Body Dimensions (L×W×H): 140×88×38mm Weight: Approximately 160g (including batteries) Housing Material: ABS Resin Display: 2×4½ digits and display symbols, visible area dimensions 52×42mm ■Operating Conditions Operating Temperature: -5 to +50℃ Storage Temperature: -25 to +65℃ Operating Humidity: 0 to 90% RH, without condensation Protection Rating: IP67 ■Power Supply Batteries: 1.5V AA batteries × 3
- Application/Performance example
- High-precision temperature measurement with two channels compatible with various thermocouples.
RTD - Thermocouple Thermometer / HD2178.1 - HD2178.2
- overview
- ■Temperature Measurement of the Thermometer Body ●RTD Sensor Pt100 Measurement Range: -200 to +650℃ Pt1000 Measurement Range: -200 to +650℃ Resolution: 0.1℃ Accuracy: ±0.05℃ Drift after 1 year: 0.1℃/year ■Thermocouple ●Thermocouple Types (Measurement Range) and Accuracy K Thermocouple (-200 to +1370℃): ±0.1℃ (up to 600℃), ±0.2℃ (beyond 600℃) J Thermocouple (-100 to +750℃): ±0.1℃ (up to 400℃), ±0.2℃ (beyond 400℃) T Thermocouple (-200 to +400℃): ±0.1℃ N Thermocouple (-200 to +1300℃): ±0.1℃ (up to 600℃), ±0.2℃ (beyond 600℃) E Thermocouple (-200 to +750℃): ±0.1℃ (up to 300℃), ±0.2℃ (beyond 300℃) Resolution: 0.1℃ Temperature Drift (at 20℃): 0.02%/℃ Drift after 1 year: 0.1℃/year *The stated accuracy only pertains to the thermometer body. Errors due to the thermocouple or cold junction reference sensor (accuracy ±0.2℃) are not included. ■Operating Conditions Operating Temperature: -5 to +50℃ Storage Temperature: -25 to +65℃
- Application/Performance example
- Temperature measurement tailored to the application allows for extensive and highly accurate temperature analysis.
-
Membership (free) is required to view all content.
Already a Member? Log In Here