【Common Specifications】 ■ Measurement Method: Membrane Electrode Method (Membrane Galvanic Cell Method) ■ Resolution: 0.01 mg/L ■ Reproducibility: 0.1 mg/L (1 cassette) ■ Number of Measurement Samples: 3-step dilution for 16 samples (up to 328 samples with cassette replacement) ■ Sample Container: Company-designated flask ■ Stirring: Magnetic Stirrer ■ Measurement Section: 3-axis control (front, back, up, down, left, right), with electrode cleaning function, 2 cassettes (24 flasks in total: 3×8) ■ Calibration: Automatic calibration with saturated water at 20°C ■ Control: Sequencer ■ Operation: Touch Panel ■ Data Processing: Computer, Monitor, Microsoft Excel ■ Utilities ・ Power Supply: AC100V 50/60Hz 5A ・ Supply Water: 0.1 MPa or more (tap water) ・ Drainage: Must allow for natural drainage ■ Installation Conditions: Ambient temperature 5–45°C, indoors without corrosive gas generation (20°C constant temperature room is desirable) *For more details, please download the PDF or feel free to contact us. For more details, please download the PDF or feel free to contact us.
---

---

--- ---
  1. 代表製品
    Automatic BOD Measuring Device "BOD-990 Series Direct Type"Automatic BOD Measuring Device "BOD-990 Series Direct Type"
    概要
    【Common Specifications】 ■ Measurement Method: Membrane Electrode Method (Membrane Galvanic Cell Method) ■ Resolution: 0.01 mg/L ■ Reproducibility: 0.1 mg/L (1 cassette) ■ Number of Measurement Samples: 3-step dilution for 16 samples (up to 328 samples with cassette replacement) ■ Sample Container: Company-designated flask ■ Stirring: Magnetic Stirrer ■ Measurement Section: 3-axis control (front, back, up, down, left, right), with electrode cleaning function, 2 cassettes (24 flasks in total: 3×8) ■ Calibration: Automatic calibration with saturated water at 20°C ■ Control: Sequencer ■ Operation: Touch Panel ■ Data Processing: Computer, Monitor, Microsoft Excel ■ Utilities ・ Power Supply: AC100V 50/60Hz 5A ・ Supply Water: 0.1 MPa or more (tap water) ・ Drainage: Must allow for natural drainage ■ Installation Conditions: Ambient temperature 5–45°C, indoors without corrosive gas generation (20°C constant temperature room is desirable) *For more details, please download the PDF or feel free to contact us.
    用途/実績例
    For more details, please download the PDF or feel free to contact us.