High reflectivity and high transmittance dichroic mirror
The dichroic mirror is designed for an incident angle of 45°. It allows transmission on the longer wavelength side of a specific wavelength while reflecting the shorter wavelength side, enabling spectral separation.
Inquire About This Product
basic information
■ DM Series - Average transmittance @ transmission wavelength range 90% (typical) - Average reflectance @ reflection wavelength range 90% (typical) - Incident angle 45±1.5° - Size 25.2 ± 0.1 mm × 35.6 ± 0.1 mm - Filter thickness 1.05 ± 0.05 mm ■ FLD Series - Average transmittance @ transmission wavelength range 90% (typical) - Average reflectance @ reflection wavelength range 97% (typical) - Incident angle 45±2° - Size 25 +0.0/-0.2 mm - Filter thickness 1.1 ± 0.1 mm ■ High durability ■ Inexpensive ■ Compatible with filter cubes from most microscope manufacturers
Price range
Delivery Time
Applications/Examples of results
■ Fluorescence observation and measurement ■ Microscopy applications ■ Biophotonics ■ Biomedical
Line up(16)
Model number | overview |
---|---|
409 DM | Reflection wavelength range 327–404nm, transmission wavelength range 415–570nm, incident angle 45° |
452 DM | Reflection wavelength range 423–445nm, transmission wavelength range 460–610nm, incident angle 45° |
497 DM | Reflection wavelength range 452–490nm, transmission wavelength range 505–800nm, incident angle 45° |
499 DM | Reflection wavelength range 470–490nm, transmission wavelength range 508–675nm, incident angle 45° |
516 DM | Reflection wavelength range 490–510nm, transmission wavelength range 520–700nm, incident angle 45° |
562 DM | Reflection wavelength range 499–555nm, transmission wavelength range 569–730nm, incident angle 45° |
585 DM | Reflection wavelength range 533–580nm, transmission wavelength range 595–800nm, incident angle 45° |
660 DM | Reflection wavelength range 594–651nm, transmission wavelength range 669–726nm, incident angle 45° |
685 DM | Reflection wavelength range 600–676nm, transmission wavelength range 695–810nm, incident angle 45° |
FLD 418 DLP | Reflection wavelength range 400–412nm, transmission wavelength range 424–1000nm, incident angle 45° |
FLD 567 DLP | Reflection wavelength range 400–561nm, transmission wavelength range 573–1000nm, incident angle 45° |
FLD 595 DLP | Reflection wavelength range 400–586nm, transmission wavelength range 604–1000nm, incident angle 45° |
FLD 642 DLP | Reflection wavelength range 400–636nm, transmission wavelength range 648–1000nm, incident angle 45° |
FLD 681 DLP | Reflection wavelength range 400–675nm, transmission wavelength range 687–1000nm, incident angle 45° |
FLD 708 DLP | Reflection wavelength range 400–701nm, transmission wavelength range 715–1000nm, incident angle 45° |
FLD 755 DLP | Reflection wavelength range 400–748nm, transmission wavelength range 762–1000nm, incident angle 45° |