AQS - Cost efficiency and energy saving of air conditioning for floors and buildings.
Air Quality System / Air Duct Installation Air Purification System
Significant reduction in electricity costs for air conditioning, heating, and humidification through air purification technology. Promotion of SDGs / reuse, filter replacement, and utilization of subsidies.
To bring air into indoor spaces, there are costs involved. Ionair utilizes air purification technology that decomposes and neutralizes substances (viruses, VOCs, PM, odors) floating in indoor spaces, providing a human-friendly environment while significantly reducing energy costs for indoor air conditioning in medium to large-scale spaces. This process enables the conversion of air that was previously exhausted into reusable air, achieving "reutilization of air conditioning exhaust air (heat recovery)" and maintaining air conditioning at low airflow, resulting in energy savings of 30-40% of annual air conditioning costs. In Japan, a lot of electricity is consumed to make the humid, hot summer air and the dry, cold winter air comfortable. However, most of this air is expelled outside after being used once. By using Ionair, energy savings are achieved through air analysis by sensors and optimal air purification based on the measured data by AI. This technology balances the maintenance of comfortable air with significant reductions in air conditioning costs, making it highly effective for large spaces where many people gather. We promise that through monitoring measurement data, we can ensure "hygienically appropriate operation" that adapts to the daily changing air conditions.
Inquire About This Product
basic information
Ionair Concentration Adjustment Device (ICE-A1000/2000 a/m) *You can choose between two types of ion generation concentration control: automatic (auto) and manual (manual). It generates the optimal ions based on the measurement data from the installed sensor. Ionair Ion Generation Module IMM Series (Small) IMK Series (Medium) IMG Series (Large) Ion Tube Length: 190 mm / 250 mm / 360 mm / 530 mm Installation Location: Inside Air Handling Unit (AHU) / Air Duct (Note) The equipment will be calculated by Ionair based on the air conditioning ventilation frequency and area volume of the target area. It does not interfere with the design and does not require daily maintenance or replenishment. It is capable of disinfecting airborne bacteria, with data showing nearly 90% disinfection effectiveness. It can be utilized for maintaining indoor air quality and infection control in airports, hospitals, nursing facilities, event halls, subways, and hotels. Currently, the use of the inquiry form on Ipros has been suspended. For inquiries, please contact us directly at the following: P 03 3288 3220 E info@ionair.jp
Price information
The price varies depending on the quantity.
Applications/Examples of results
Air purification / Ventilation suppression effect / Significant reduction in power consumption (energy saving and CO2 reduction) Solutions for promoting SDGs Virus inactivation effect, assistance in improving ventilation efficiency (Implementation facilities) Hotels, stores, shopping malls, amusement parks (casinos) Subway stations, schools, event facilities, offices, restaurants, airports Infection prevention measures in medical facilities such as nursing homes and hospitals Removal of odor substances (deodorization) - Deodorization of garbage storage areas and cleaning facilities - Deodorization of wastewater treatment facilities - Air purification in animal research facilities - Air purification in food factories - Deodorization of smoking areas Implementation results (partial) Wynn Resorts Casino (Macau, China) Park Hyatt and Grand Hyatt Hotels (Shanghai, China) Shopping mall "dez" (Innsbruck, Austria) Zurich International Airport (Switzerland) Siemens TS (Berlin, Germany) St. Jakob-Park soccer stadium (Basel, Switzerland) Kanazawa Umimirai Library (Ishikawa Prefecture) Cantonal Hospital (Aarau, Switzerland)
Detailed information
-
Image of installation in a duct.
-
This is an example of the AQS system configuration. By installing four types of sensors in the air conditioning ducts, air measurements are conducted. Based on that data, an appropriate ion concentration is generated. Additionally, the measurement data used during generation can be linked with the building management system.
-
This is an image of ion generation. By applying a constant high voltage to the generation tube, oxygen ions are produced from the air. Oxygen ions have properties similar to ozone, including odor removal and the ability to decompose chemical substances, but a characteristic of oxygen ions is that they have no impact on the human body.
Line up(3)
Model number | overview |
---|---|
IMM Series | Effective indoor space volume (300 - 800 m3) is ideal for small spaces and living room air purification, suitable for installation in individual rooms. |
IMK Series | This is a model designed for medium-sized spaces. It accommodates effective room volumes of 600 - 3600 m3 due to the configuration of the ion generation tube. |
IMG Series | This model is designed for large facility spaces. It covers air purification for an entire floor or an entire building. Effective room volume of 1200 - 7200 m3 per unit, and multiple IMG series units can be installed. |
catalog(2)
Download All CatalogsCompany information
Founded in 1993 under the name "LK Luftqualität AG," the company currently operates under the name "ionair." It is a Swiss company that boasts a track record of over 10,000 installations in Japan, offering deodorization, air purification, and energy-saving systems. The ionair system generates oxygen ions using the corona discharge effect. It produces fresh and clean air without the use of chemicals, ultraviolet light, or ozone. Additionally, it is designed for use in occupied environments. - Deodorization Effect - By exposing contaminated air to oxygen ions, the system oxidizes and decomposes odor molecules and VOCs, breaking down and neutralizing the substances causing odors and converting them into water and carbon dioxide. - Air Purification Effect - Indoor air is more than five times more polluted than outdoor air. Ionair decomposes and neutralizes harmful substances such as chemicals, pollen, and viruses using oxygen clusters that have no adverse effects on the human body. - Energy-Saving Effect - By equipping the ducts of first-class ventilation air conditioning units, the system can reduce the airflow of the air conditioning unit. Furthermore, by increasing the amount of recirculated air and reusing exhaust air, it can significantly lower electricity costs associated with heating and cooling.