For measuring the "irradiance" and "dose" of sterilizing UV light sources!
Short-wavelength, high-energy ultraviolet light in the UV-C spectrum from 100nm to 280nm is widely used for sterilization/disinfection of air, surfaces, and water. To ensure safety from excessive exposure to ultraviolet light while confirming the effectiveness of ultraviolet germicidal irradiation (UVGI), measurements of the sterilization light source and irradiation area are conducted. Gigahertz-Optik offers a wide range of radiometers and spectroradiometers designed and calibrated for the accurate measurement of the irradiance [μW/cm²] and dose [mJ/cm²] of such sterilizing UV light sources. 【Target Light Sources】 - Low-pressure mercury lamp: Wavelength 253.7nm - UV-C LED: Wavelength 265-280nm - Excimer lamp (KrCl): Wavelength 222nm ■ UV Radiometer (Handheld) Ideal for daily measurement of the irradiance of commercially available UVC light sources. It is a low-cost and easy-to-operate measuring instrument. ■ UV Spectroradiometer (Measuring device for spectral irradiance and spectral flux of sterilizing UV) Perfect for research work and product development. It provides the highest radiation accuracy regardless of the type of radiation source. *For more details, please refer to the PDF document or feel free to contact us.
Inquire About This Product
basic information
For more details, please refer to the PDF document or feel free to contact us.
Price range
Delivery Time
Applications/Examples of results
【Applications】 ■UV-C LED ■Low-pressure mercury lamp ■Excimer lamp ■Xenon lamp *For more details, please refer to the PDF document or feel free to contact us.
Detailed information
-
UV Radiometer | X1 & UV-3725 ■ Calibrated at 254nm for low-pressure mercury lamps ■ Radiant intensity and dose measuring instrument with peak hold function ■ Wide dynamic range for measuring sterilization effects and photobiological safety ■ Good incident angle correction - Measurement wavelength range: 254nm - Incident optical system: φ8mm diffuser - Minimum measurement value (Typ): 0.004μW/cm² - Maximum measurement value (Typ): 2000mW/cm²
-
UV Radiometer | X1 & UV-3726 ■ Calibration settings: UV-C LED ⇒ 5nm step, low-pressure mercury lamp ⇒ 254nm ■ Radiant intensity and dose measuring instrument with peak hold function ■ Wide dynamic range for measuring sterilization effects and photobiological safety - Measurement wavelength range: 250–300nm - Incident optical system: φ11mm diffuser - Minimum measurement value (Typ): 0.002μW/cm² - Maximum measurement value (Typ): 1000mW/cm²
-
UV Radiometer | X1 & UV-3727 ■ For excimer lamps (Kr-Cl), low-pressure mercury lamps, and UV-C LEDs ■ Calibrated at 222 nm, 254 nm, and 250-300 nm in 5 nm increments ■ Radiant intensity and dose measuring instrument with peak hold function ■ Wide dynamic range for measuring sterilization effects and photobiological safety - Measurement wavelength range: 250-300 nm - Incident optical system: φ19.2mm diffuser - Minimum measurement value (Typ): 0.002μW/cm² - Maximum measurement value (Typ): 1000mW/cm²
-
UV Radiometer | X1-UV-3718 ■ Calibrated at 254nm for low-pressure mercury lamps ■ Radiant intensity and dose measuring instrument with peak hold function - Measurement wavelength range: 254nm - Incident optical system: φ11mm diffuser - Minimum measurement value (Typ): 0.005μW/cm² - Maximum measurement value (Typ): 2500mW/cm²
-
UV Spectroradiometer | BTS2048-UV ■ Spectroradiometer optimized for UV ■ Equipped with a precision cosine diffuser, compact lab-grade equipment - Measurement wavelength range: 200–430nm - Incident optical system: φ10mm cosine diffuser f2≤3% - Optical bandwidth: 0.8 nm - Minimum measurement range: 0.1mW/(m²nm) @ 265nm - Maximum measurement range: 100kW/(m²nm) @ 265nm
-
UV Spectroradiometer | BTS256-UV ■ Ultra-thin UV spectroradiometer equipped with an integrated display for high-brightness UV radiation - Measurement wavelength range: 200–525nm - Incident optical system: φ9mm cosine diffuser - Optical bandwidth: 2.8 nm - Minimum measurement range: 20mW/(m²nm) @ 265nm - Maximum measurement range: 10kW/(m²nm) @ 265nm
-
UV Spectroradiometer | TFUV10 ■ A measurement system for the spectral radiance intensity of UV LEDs in the wavelength range of 200 nm to 550 nm ■ A complete measurement system equipped with an integrating sphere, spectroradiometer, software, and calibration - Measurement wavelength range: 200–550 nm - Incident optical system: φ100 mm integrating sphere, φ25.4 mm incident port - Optical bandwidth: 1 nm - Minimum measurement range: 0.02 µW/nm @ 265 nm - Maximum measurement range: 20 W/nm @ 265 nm
-
Disk-type UV Radiometer | Cure-Met ■ Two types of lineup for UV LEDs and UVA light sources ■ Internal memory and battery for time-resolved logging (for conveyor belt applications) ■ Cosine-corrected field of view ■ Slim design, resistant to high temperatures and high UV exposure during UV curing - Spectral responsiveness: 328–382nm (UVA model), 350–460nm (LED model) - Measurement range: 1 mW/cm² to 10 W/cm²
catalog(9)
Download All CatalogsCompany information
Opto Science was established in 1987 and is an import trading company that introduces advanced products from overseas. The range of products we handle is diverse, but as our company name suggests, many of them utilize "light" and are related to "science." Specifically, we deal with optical components and optical devices related to lasers, inspection systems that utilize the properties of light, and key modules among other products. The products we handle receive strong support from researchers and engineers around the world. We quickly introduce and provide these products to universities, research institutions, and industrial sectors in Japan.