Is the data source safe? The data diode OWCD "Data Secure Link" can prevent intrusions by restricting communication in one direction.
One-way communication restriction device data diode "OWCD" The recognition among infrastructure engineers and security engineers has been increasing. You are already aware of it, right? One reason for the support of the simple structure of the data diode, which is dedicated to flowing communication in one direction from left to right, is its capability. However, relying solely on that capability can be cumbersome for utilization. Therefore, we have established a new lineup that responds to various communication needs, starting with making communication protocols that require bidirectionality flow in one direction, protocol conversion according to the recipient's circumstances such as the Internet, and even enhancing value through information collection and analysis. The data diode OWCD "Data Secure Link." It is absolutely not allowed for anything to enter internally. In response to this, it enables customers to secure their security and is suitable for utilization in digital transformation (DX). As DX progresses, the operational management becomes increasingly challenging along with the communication volume. Please make use of the data diode OWCD "Data Secure Link," which can be used easily and clearly, with minimal running costs, ensuring safe and secure operations. There is a video introducing the principle; please check the related link below.
Inquire About This Product
basic information
There are various setup methods. 1000Mbase-T (RJ-45) connection is standard. Effective value (standard setting) is 300Mbps. The device has a built-in Windows OS. It also includes Trelix Embedded Control as its own antivirus measure, so you can use it with peace of mind. - Supports TCP, UDP, SMTP relay, OPC UA, and SNMP traps. - Also compatible with HTTPS and MQTT. For file transfer, please use the sibling product "File Secure Link." In addition to this, models that support low communication bandwidth and existing models that can be used in combination with separate PCs are also available. Please contact us through the related links above.
Price information
Focusing on the basic model, - We want to support multiple communication protocols. - We want to incorporate our own service programs. - There won't be such a large amount of file transfers. - Computers will be provided separately. Please feel free to consult us about customization for customers. The core air gap, chassis, and motherboard can be customized according to customer needs. Please also consult us about communication integration within the customer network. We will provide the necessary engineering support. Please contact us through the related links above.
Price range
P5
Delivery Time
※It is made to order. The standard delivery time for the basic model is 12 weeks. Please contact us via the related link above.
Applications/Examples of results
The sending computer receives data and immediately transmits it to a receiving computer in another security zone via the data diode OWCD. - It supports TCP, FTP, UDP, SMTP relay, OPC UA, and SNMP traps. - It also supports HTTPS and MQTT. In addition, functionality can be added to both the sending and receiving sides. - In the case of database integration, there is also the option of file transfer if the data is temporarily converted into a file. - We accept inquiries regarding DIN rail mounts or wall mounts for integration into control panels, including communication effective values. - We can also provide functionality to collect data directly from sensors or PLCs and transmit it via OPC UA, HTTPS, or MQTT. - Database recording, web-based data visualization, and direct integration with customer service-specific terminals are also possible. - Features for analysis and detecting unusual changes can also be implemented. It prevents intrusions from communication routes far more robustly than a password lock. In addition to production equipment DX and IoT, it is also used for secure communication in government agencies and other organizations. Please contact us through the related links above.
Detailed information
-

A data diode is a device that restricts communication to one direction. The data diode OWCD prevents unauthorized access and data exfiltration via viruses by using a route for file transfer. We have established features to better utilize this characteristic. It is a "data secure link" that connects computers that cannot see each other due to different security management zones. Even those who are not communication security experts, such as firewall or router specialists, can easily configure it. We started with support for communication protocols and equipped it with the ability to respond to various applications, allowing for customization as well. Please make use of it.
catalog(6)
Download All Catalogs
Company information
Our company is a member of the Mitsubishi Heavy Industries Group, serving as a design technology partner for Mitsubishi Heavy Industries, where we engage in planning and mechanical design for prime movers (steam turbines/boilers, gas turbines, water turbines), pumps, and various plants, as well as instrumentation control system planning and electrical design. In order to meet the increasingly diverse and sophisticated needs of our customers, we will continue to challenge ourselves to improve our technological capabilities, streamline operations, and reduce costs based on the trust we have built with users. Through this, we are developing activities that contribute to society by providing the products and engineering capabilities we have cultivated so far to everyone. Alongside the sale of products related to IoT, manufacturing DX, and on-site monitoring/condition monitoring, we will focus on custom orders, customization, and system construction to realize your ideas. We encourage you to consider utilizing our services. https://eng.power.mhi.com