We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for CT scanner.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

CT scanner Product List and Ranking from 34 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Dec 17, 2025~Jan 13, 2026
This ranking is based on the number of page views on our site.

CT scanner Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Dec 17, 2025~Jan 13, 2026
This ranking is based on the number of page views on our site.

  1. Comet Technologies Japan K.K. Comet Yxlon Kanagawa//Testing, Analysis and Measurement
  2. null/null
  3. アールエフ Nagano//Medical Devices
  4. 4 null/null
  5. 5 null/null

CT scanner Product ranking

Last Updated: Aggregation Period:Dec 17, 2025~Jan 13, 2026
This ranking is based on the number of page views on our site.

  1. Equipped with a newly developed nano-focus X-ray tube! 【Industrial X-ray CT】 Comet Technologies Japan K.K. Comet Yxlon
  2. No. 21 Evaluation of Pore Structure by NLDFT Method and GCMC Method
  3. 研究開発機器 中古販売サービス
  4. Shimadzu X-ray CT device InspeXcio7000
  5. 4 Evaluation of Activated Carbon Fiber Structure Using No. 10 T-Plot Method (Application Edition 1)

CT scanner Product List

91~102 item / All 102 items

Displayed results

"Linear CT" is a new technology for tomography that performs inline inspection without stopping the inspection object.

Overview of new technology, benefits of implementation, and comparison images with conventional CT using battery cross-sectional images as an example!

We are currently developing a new technology called "Linear CT" (as of June 2025). In this article, we will provide an overview of this new technology, the benefits of its implementation, and comparison images with conventional CT using battery cross-sectional images as examples. If you are interested in "Linear CT," please feel free to contact us. *You can view the detailed content of the blog through the related links. For more information, please download the PDF or feel free to reach out to us.*

  • X-ray inspection equipment
  • X-ray Inspection Machine

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

MolcerPlus Orientation Analysis Options

From industrial products to biological specimens. We will showcase everything beautifully and with comfortable operation.

Extract and analyze the directional components within a 3D object. It is useful for fiber orientation and crack analysis. It has functions for orientation analysis and directional analysis.

  • Image analysis software

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

X-ray inspection Large X-ray CT system [Contracted inspection]

We provide X-ray inspection services! We have obtained certifications such as Nadcap and JISQ9100!

X-ray inspection is a non-destructive testing method that observes internal structures, casting and welding defects, and foreign objects from CT scan image data. The inspected object can be rotated 360 degrees, allowing for the acquisition of high-precision 3D images from multiple viewpoints. Equipped with one of the largest outputs in the country and high-resolution sensors, it can capture a variety of products. The maximum scan size is φ900mm × 1000mm, accommodating large products as well. Comprehensive aftercare is also provided by specialized inspectors.

  • Contract Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

X-ray examination X-ray CT device [Contracted inspection]

We offer X-ray inspection services! We have obtained certifications such as Nadcap and JISQ9100!

The CT.Compact X-ray CT device is a radiation inspection technology that can obtain high-precision images while being compact and lightweight. Our company conducts contract inspections using this device, which is utilized in various fields such as manufacturing and the medical industry. The CT.Compact X-ray CT device can capture images at high speed while rotating the inspected object 360 degrees, allowing for non-destructive inspection of the internal structure, fine defects, and foreign objects of the inspected item. It also employs a highly sensitive image detector, enabling the acquisition of high-quality images. By utilizing advanced image processing technology, the brightness and contrast of the images can be freely adjusted. Our CT.Compact X-ray CT device is used for fine inspections of automotive parts, mechanical components, electronic parts, and more, thanks to its compact size and high-precision image acquisition capabilities. With advanced analytical technology and high-quality image acquisition capabilities, we can provide accurate and rapid inspections tailored to our customers' needs. We encourage you to make use of our CT.Compact X-ray CT device.

  • Contract Inspection

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Germany Large Linear Accelerator High Power Industrial CT diondo d7

High-performance linear accelerator CT device for the analysis and inspection of high-density components.

The Diondo D7 is developed for the analysis of inspection objects that are difficult to penetrate, particularly large specimens, and is suitable for analyzing high-density material components such as titanium, copper, steel, or thick aluminum (e.g., engines, crankcases, stators, turbine blades). The applications of this system primarily focus on component analysis to detect manufacturing defects and material flaws, as well as inspecting the shape and thickness of test specimens. Furthermore, the Diondo D7 can be equipped with linear accelerators of various performance levels to meet diverse customer needs. ▪ Linear Accelerator Performance levels of 3MeV, 6MeV, 9MeV, continuously adjustable ▪ Mechanical System Various sizes can be customized according to customer needs. ▪ Flat Panel Detector High-resolution (140μm) flat panel detector optimized for linear accelerator CT ▪ Line Array Detector High-resolution (200μm) linear array detector optimized for linear accelerator CT

  • Radiation detector
  • X-ray inspection equipment
  • Contract Analysis

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Observation of the internal state of delayed-release OD tablets.

The cause has become visually clear, contributing to the formulation of a policy for improvement at the customer level!

We will introduce a case that contributed to customer process improvement by capturing the changes in the internal structure of OD tablets before and after a rigorous test. X-ray CT is a non-destructive method that visualizes the spatial distribution of X-ray absorption rates within a sample. When changes occur inside the sample, there may be corresponding changes in the distribution of X-ray absorption rates, and by quantifying these changes, it is possible to infer what kind of changes have taken place inside the sample. The value "skewness," which represents the shape of the histogram of X-ray absorption rates within a region of a certain size, is one of the useful quantities that indicates the state of the sample's interior. 【Flow of Data Acquisition and Analysis】 ■Sample ■X-ray CT Observation ■3D X-ray Absorption Rate Data ■Data Analysis ■3D Distribution of Skewness of Absorption Rate Distribution in Multiple Regions *For more details, please refer to the PDF document or feel free to contact us.

  • X-ray Inspection Machine

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Investigation of Internal Defects in Metal Parts

You can check for the presence of internal defects without damaging the sample!

Regarding aluminum die-cast parts, information such as the presence of internal defects can be obtained through non-destructive observation using a 3D X-ray microscope (X-ray CT). Additionally, if defects are confirmed internally, the defects can be exposed and assessed through cross-sectional processing using techniques such as ion milling. When inclusions are present, the cause of occurrence can be estimated by confirming their composition. Please feel free to contact us if you have any inquiries. [Overview] ■ Acquisition of internal information through non-destructive observation (X-ray CT) ■ Cross-sectional structural analysis (cross-sectional processing + elemental analysis) *For more details, please download the PDF or feel free to contact us.

  • Other analysis and evaluation services

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Fault image (X-ray CT/FIB SEM, etc.) 3D analysis ExFactVR

Fault image (X-ray CT/FIB SEM, etc.) 3D analysis software ExFact VR

"ExFact VR 2.0" is a three-dimensional tomographic image visualization software that visualizes tomographic images obtained from X-ray CT and other sources in two-dimensional and three-dimensional formats through volume rendering. The screen layout clearly shows the correspondence between cross-sectional images, three-dimensional images, and additional information. It allows for easy independent adjustment of 2D/3D images and enables immediate output of reports in a visual format. By creating and distributing movie files with this software, you can intuitively convey the two-dimensional and three-dimensional images of samples to others. It also takes into account users who only view the data without directly using the equipment or software, maximizing the significance of expensive devices like X-ray CT and expecting a ripple effect of benefits. 【Features】 ■ Equipped with our proprietary technology, VR-VR technology ■ Rich functionality for automatically and quickly creating diverse reports ■ Reduces the workload for operators ■ Practical user interface and architecture *For more details, please refer to the catalog or feel free to contact us.

  • Contract Analysis
  • Image analysis software
  • Image Processing Software

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

パルスECT装置 Lyft

パルス ECT(PEC)の革新!CUIの測定が今、見直される

パルスECT装置Lyftは、パルスECT(PEC)技術を用いて、保温材下の母材(炭素鋼配管)の腐食を、保温材を取り外すことなくスクリーニング検査できる装置です。ポータブルタイプの世界最高水準・最新式機器であり、Grid mapping mode(分割計測)もしくはDynamic mode(連続計測)によるリアルタイムのC-スキャン画像化、高速のデータ取得(最大15points/s)を実現します。

  • Defect Inspection Equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Research Material] World Market for Intraoperative CT

World Market for Intraoperative CT: Mobile Intraoperative CT, Fixed Intraoperative CT, Hospitals, Clinics, Others

This research report (Global Intraoperative CT Market) investigates and analyzes the current state and outlook for the global intraoperative CT market over the next five years. It includes information on the overview of the global intraoperative CT market, trends of major companies (sales, selling prices, market share), market size by segment, market size by major regions, and distribution channel analysis. The segments by type in the intraoperative CT market focus on mobile intraoperative CT and fixed intraoperative CT, while the segments by application target hospitals, clinics, and others. The regional segments are divided into North America, the United States, Europe, Asia-Pacific, Japan, China, India, South Korea, Southeast Asia, South America, the Middle East, and Africa, to calculate the market size for intraoperative CT. It also includes the market share of major companies in the intraoperative CT market, product and business overviews, and sales performance.

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration