We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Darkroom.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Darkroom(10m) - List of Manufacturers, Suppliers, Companies and Products

Last Updated: Aggregation Period:Sep 17, 2025~Oct 14, 2025
This ranking is based on the number of page views on our site.

Darkroom Product List

16~30 item / All 68 items

Displayed results

Vibration and Temperature Prognostic Monitoring System 'vibInsight'

Achieving data collection from a wide range! Monitoring system adopting a wireless relay network method.

"vibInsight" is a vibration and temperature predictive monitoring system that utilizes a wireless relay transmission system to enable data collection from a wide range. The cause of equipment and rotating machinery failures is nearly half due to bearing failures. By regularly measuring peak values and checking trends, it is possible to detect anomalies. Furthermore, with a response frequency of 20kHz, it captures signals from low to high speeds without loss and converts them into electrical signals. 【Features】 ■ Data collection from multiple buildings and multiple floors is possible with MAX10 relay stages. ■ Data can be collected beyond just bearing vibrations: - Ambient temperature - Current ■ New sensor designs can also be added. *For more details, please refer to the PDF materials or feel free to contact us.

  • Other FA equipment
  • Production Management System
  • Other network tools

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Introduction to e-Otama Co., Ltd. "Yamanashi EMC Center"

A testing laboratory equipped with emission and immunity facilities capable of testing large machinery.

At e-Otama Co., Ltd.'s "Yamanashi EMC Center," we can conduct EMC testing for large equipment (with a power capacity of up to 100A, a weight of 4.5 tons, and dimensions of approximately 3m on each side). We have an ideal open site that emphasizes data reproducibility, along with a comprehensive range of peripheral devices and facilities. 【Features】 ■ Usage fees are lower than those of an anechoic chamber, and measurement times are almost the same as in the chamber. ■ Data correlation between testing facilities is significantly better than in an anechoic chamber. ■ High level of completeness used as a standard for the construction of EMC regulatory authority sites in Asian countries. *For more details, please download the PDF or feel free to contact us.

  • EMC Testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

RF1 set (magnetic field and electric field probes)

It is possible to measure electric and magnetic fields from 30MHz to 3GHz on electronic assemblies during the development process!

The "RF1 Near-Field Probe Set" includes four passive magnetic field probes and one dedicated cable. The probe heads in this set allow for measurements very close to electronic assemblies. It can inspect IC pins, conductive paths, components, and connectors, and identify sources of interference. 【Set Contents】 ■RF-K 7-4: H-Field Probe 30MHz to 1GHz ■RF-U 2.5-2: H-Field Probe 30MHz to 3GHz ■RF-R 3-2: H-Field Probe 30MHz to 3GHz ■RF-E 10: E-Field Probe 30MHz to 3GHz ■SMB-BNC: 1m cable ■Case *For more details, please refer to the related links or feel free to contact us.

  • EMC countermeasure products

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

XF1 Set (Magnetic Field and Electric Field Probe)

Can be connected to a 50Ω input spectrum analyzer or oscilloscope!

The "XF1 Near-Field Probe Set" includes four magnetic field probes, one electric field probe, and one dedicated cable. It is capable of measuring electric and magnetic fields from 30MHz to 6GHz on electronic assemblies during the development process. Due to its impedance matching, the sensitivity in lower frequency ranges is lower than that of RF-type probes. 【Set Contents (Partial)】 ■XF-R 400-1: H-Field Probe 30MHz–6GHz ■XF-R 3-1: H-Field Probe 30MHz–6GHz ■XF-B 3-1: H-Field Probe 30MHz–6GHz ■XF-E 10: E-Field Probe 30MHz–6GHz ■XF-U 2.5-1: H-Field Probe 30MHz–6GHz ■SMA-SMA: 1m Cable *For more details, please refer to the related links or feel free to contact us.

  • EMC countermeasure products

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Noise Vision - Electromagnetic Shielded Room Rental Service

Please leave the measures and considerations regarding antenna radiation emission and noise terminal voltage before certification to Wave Technology!

With the acceleration of machinery, there is a growing trend for EMI (Electro-Magnetic Interference) countermeasures to take up a larger proportion in the product development process. In such a situation, are you having trouble securing an anechoic chamber or engineers for EMI countermeasures and verification?

  • Contract measurement
  • EMC Testing
  • Rental/lease

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Electric Field Probe "FL8000 Series"

Capable of measuring CW and pulse modulation with a single unit.

The new AR probe "FL8000 series" covers a frequency range of 5 kHz to 60 GHz and an electric field strength of 0.3 to 1000 V/m. It achieves a wide frequency range and dynamic range, simplifying your testing with just one device. By using a laser to supply power through fiber, continuous operation is possible without the need for battery recharging or replacement. *For more details, please refer to the PDF. Feel free to contact us as well.

  • Ammeter
  • Analytical Equipment and Devices
  • probe

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Radio Wave Dark Room CTC Component Chamber

The Frankosorb hybrid electromagnetic wave absorber is arranged in an optimal layout for the ferrite absorption material lining!

The "CTC Component Testing Chamber" is a customized component testing chamber solution by Frankonia for immunity testing of commercial products, automotive parts, and military components. It is compliant with CISPR 25 and ISO 11452 for automotive parts testing at a test distance of 1.0m, as well as MIL-STD 461 and DO-160 testing at the same distance. Additionally, it meets the compliance requirements of IEC EN 61000-4-3 at a measurement distance of 3.0m. 【Features】 ■ A compact chamber solution for component testing compliant with CISPR 25 and MIL-STD 461/DO-160 ■ EMS measurements fully compliant with IEC/EN 61000-4-3 ■ Excellent performance with Frankonia's original Frankosorb electromagnetic wave absorber ■ Compact chamber design with optimized absorber lining ■ Turnkey solution *For more details, please refer to the related links or feel free to contact us.

  • EMC Testing

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Coupling/Decoupling "FP-SURGE 100M2"

Surge/ring wave CDN (manual)! The rated current is 0 to 100A.

We would like to introduce our coupling/decoupling device, 'FP-SURGE 100M2'. Surge/ringing wave CDN (manual). Current range 0-100A AC/DC, compliant with IEC 61000-4-5 Ed.3 and ANSI C62.41. The maximum AC voltage is 50/60Hz, 690V (phase-to-phase) / 400V (phase-to-neutral). Please feel free to contact us if you have any inquiries. 【Features】 ■ Surge/ringing wave CDN (manual) ■ Current range 0-100A AC/DC, compliant with IEC 61000-4-5 Ed.3 and ANSI C62.41 ■ Maximum AC voltage 50/60Hz, 690V (phase-to-phase) / 400V (phase-to-neutral) ■ 8kV pulse voltage * You can download the German version of the catalog. * For more details, please feel free to contact us.

  • Other network tools

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

LF1 set (magnetic field probe)

Using high-resolution probes such as LF-B 3, LF-U 5, and LF-U 2.5 to detect interference sources more accurately!

The "LF1 Near-Field Probe Set" includes four magnetic field probes and a dedicated cable, allowing for the measurement of longwave, mediumwave, and shortwave frequencies emitted from electronic devices during the development process. The probe heads in this set are designed to progressively detect electromagnetic interference sources from IC pins to large components on the assembly. They can be connected to a spectrum analyzer or oscilloscope with a 50Ω input. 【Set Contents】 ■LF-R 400: H-Field Probe 100kHz to 50MHz ■LF-B 3: H-Field Probe 100kHz to 50MHz ■LF-U 2.5: H-Field Probe 100kHz to 50MHz ■LF-U 5: H-Field Probe 100kHz to 50MHz ■SMB-BNC: 1m Cable ■Case *For more details, please refer to the related links or feel free to contact us.

  • EMC countermeasure products

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Microwave and millimeter wave measurement anechoic chamber

Completely customized to your requests! We propose suitable sizes according to your usage and installation location.

We would like to introduce the "Microwave and Millimeter Wave Measurement Anechoic Chamber" that we handle. The size starts from approximately W3000×D2000×H2400mm, and we can suggest suitable sizes based on the application and installation location. It features a wide frequency range from 100MHz to 500GHz and simulates QZ size and anechoic characteristics. 【Features】 ■ Completely customizable according to your requirements ■ Wide frequency range (100MHz to 500GHz) ■ Optimization of QZ ■ Proposals including antennas, antenna masts, turntables, and measurement software *For more details, please refer to the related links or feel free to contact us.

  • EMC/Static electricity measuring equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

RF-E 09 (E field electric field probe)

The same basic structure as the "RF-E 03" and "RF-E 04" probes!

The RF-E 09 electric field probe is a passive near-field probe designed for use with scanners manufactured by Langer. The electrodes of the probe head detect separated electric fields on the surface of ICs. It functions well within a distance of 0.5 to 10 mm from the assembly. By placing and holding small square electrode surfaces on components or printed circuit boards, it can detect sources of electrical interference. 【Specifications】 ■ Type: Near-field probe ■ Size: 10x10 mm probe head ■ Frequency range: 30 MHz to 3 GHz ■ Connector: SMB male, Jack *For more details, please refer to the related links or feel free to contact us.

  • EMC/Static electricity measuring equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Millimeter wave anechoic chamber

Millimeter-wave anechoic chamber usable for performance evaluation of millimeter-wave collision avoidance radar, etc.

We handle a millimeter-wave anechoic chamber that can be used for performance evaluation of millimeter-wave collision avoidance radar, which is becoming standard in the automotive market. With the installation of a traverse (moving rail), we offer options that allow for a certain degree of flexibility in measurement distance, and we can respond flexibly with equipment tailored to your needs. Additionally, we provide a total solution along with a target simulator (our own MRT7681) that can simulate objects for the radar. 【Specifications Example】 ■ Dimensions: 3,200×6,200×3,200mm ■ Frequency Range ・800MHz to 40GHz ・75GHz to 110GHz ■ Test Range: Approximately 4,000mm QZφ1,000mm ■ Anechoic Characteristics ・800MHz -30dB ・1GHz -35dB ・3GHz to 110GHz -45dB *For more details, please download the PDF or feel free to contact us.

  • Testing Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

XF-E 09s (E field electric field probe)

Compact and very easy to use, and with the current attenuation sheath, it is electrically well shielded!

The "XF-E 09s" electric field probe is a passive near-field probe. The electrodes of the probe head detect separated electric fields on the surface of the IC. It works well within a distance of 0.5 to 10 mm on the assembly. It has the same basic structure as the "XF-E 04s" probe, but by placing and holding small square electrode surfaces on components or printed circuit boards, it can detect sources of electrical interference. 【Specifications】 ■ Type: Near-field probe ■ Size: 10x10mm probe head ■ Frequency range: 30MHz to 6GHz ■ Connector: SMA female, Jack *For more details, please refer to the related links or feel free to contact us.

  • EMC/Static electricity measuring equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

LF-R 50 (H field magnetic field probe)

The larger head allows for the detection of larger components as potential sources of interference!

The "LF-R 50 Magnetic Field Probe" is a passive near-field probe with a head size of 10mm in diameter, designed to measure assemblies, devices, or cables up to 3cm away. This product offers performance that is intermediate between the "LF-R 400" and "LF-R 3" probes in terms of diameter, sensitivity, and resolution. Langer's near-field probes are compact and very easy to use, and they are electrically well-shielded due to the current-damping sheath. 【Specifications】 ■ Type: Near-field Probe ■ Size: Φ10mm Probe Head ■ Frequency Range: 100kHz to 50MHz ■ Connector: SMB male, Jack *For more details, please refer to the related links or feel free to contact us.

  • EMC/Static electricity measuring equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Distant Realm Spiral 'TC-93061A'

The supported frequency range is 700 to 7500 MHz! It enables a reduction in measurement time and costs.

The TC-93061A is an ultra-compact, wideband far-field spiral. The far-field type is used at a distance of 50 to 200 mm from the DUT. Accurate positioning is not required, but it is recommended for use in medium to large shielded boxes. The supported frequency range is 700 to 7500 MHz, and the dimensions (WxDxH) are 106x130x15.6 mm. Custom manufacturing is also possible to accommodate changes in the movable range, so please feel free to consult us. 【Features】 - Suitable for measurements inside medium to large shielded boxes - Well-equipped dedicated fixtures for polarization switching and XYZ axis position adjustment - Reduction of measurement time and cost - Ultra-compact - Wideband *For more details, please refer to the related links or feel free to contact us.

  • Other electronic parts

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration