Load cell
Load cell
Compact and lightweight, made of all stainless steel, suitable for use in corrosive environments.
- Company:三友電子工業
- Price:10,000 yen-100,000 yen
Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.
Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.
181~195 item / All 267 items
Load cell
Compact and lightweight, made of all stainless steel, suitable for use in corrosive environments.
Load cell
It is suitable for high-precision measurement with a compact and lightweight design.
Load cell
It is a compact and lightweight compression-tension dual-purpose load cell, suitable for high-precision weighing systems.
Load cell
Suitable for tank scales/hopper scales and various other tension measuring devices. It is standard for high precision in tensile load, but can also be used for tensile compression. Manufacturer link: http://www.minebea-mcd.com/product/loadcell/tension/u3s1.html
Load cell
It is suitable for measuring small loads and thread tension. It is a cantilever type.
Load cell
It is a compact and lightweight compression-tension dual-purpose load cell made of all stainless steel.
Load cell converter board
The A-621L is a load cell converter that uses a low-noise instrumentation amplifier IC. It operates on a single 5V power supply with a required current of 25mA. It has a built-in power supply for driving the load cell, allowing direct connection to a 350Ω load cell. The power supply for the load cell provides a voltage of 3.89V ±5%, with a maximum current of 12mA. It is equipped with a trimmer for sensitivity adjustment and a trimmer for offset adjustment, making it easy to calibrate. The rated output is 2V (+2.5V ±2V). The sensitivity adjustment range is 0.5mV to 2.2mV/V, and the offset adjustment range is ±0.5V. The dimensions are 55×30×13 mm.
24V power supply load cell converter
Load cell converter operating on +24V power supply. Ideal for use in combination with sequencers and other devices. Rated output is ±10V/FS, with a response frequency of 340Hz (-3dB). It has a built-in +5V power supply for driving load cells, allowing direct connection to 350Ω load cells. Equipped with trimmers for sensitivity adjustment and offset adjustment, making it easy to adjust. Sensitivity adjustment range is 1mV/V to 3mV/V, and offset adjustment range is ±1.8V. Required power supply is 24V, 40mA. Uses snap-in terminal blocks for input and output. External dimensions are 80×55×17.
Load cell converter with peak hold function
The A-62LH is a load cell converter equipped with two peak hold outputs. It can hold maximum and minimum value outputs. It uses the low-noise instrumentation amplifier IC, AD8221AR, from Analog Devices. It operates on a single +5V power supply with a required current of 50mA. It has a built-in power supply for driving load cells, allowing direct connection to a 350Ω load cell. The power supply for the load cell provides a voltage of +3.89V ±5%, with a maximum current of 12mA. It is equipped with trimmers for sensitivity adjustment and offset adjustment, making it easy to calibrate. The rated output is 2V (+2.5V ±2V). The sensitivity adjustment range is 0.5mV to 2.2mV/V, and the offset adjustment range is +2.5V ±0.2V. The dimensions are 60×40×12 mm.
4-20mA current output load cell converter
The A-M4 is a load cell converter with a current output (4-20mA) type. It operates on a 24V power supply and is ideal for use in combination with sequencers and other devices. It has a built-in +5V power supply for driving load cells and can be directly connected to a 350Ω load cell. It is equipped with trimmers for sensitivity adjustment and offset adjustment, making it easy to adjust. The sensitivity adjustment range is 1mV/V to 3mV/V, the offset adjustment range is ±10%/FS, and the response frequency is 340Hz (-3dB). The required power supply is 24V, 50mA. It uses a one-touch terminal block for input and output. The external dimensions are 80×55×17.
High-gain converter for low-sensitivity load cells
Small high-precision high-gain converter compatible with low-sensitivity load cells for civil engineering.
Load cell converter with 6-digit display using a 24-bit sigma-delta ADC.
Using a low-noise AD converter, it features a low price with a 6-digit display.
24-bit AD converter with a 6-digit display load cell transducer.
Low price with 6-digit display
±10V output load cell converter
Load cell converter using Analog Devices' low-noise instrumentation amplifier IC, AD8221AR. The rated output is ±10V/FS, and the response frequency is 2.8kHz (-3dB). It has a built-in +5V power supply for driving the load cell and can be directly connected to a 350Ω load cell. It is equipped with a trimmer for sensitivity adjustment and a trimmer for offset adjustment, making it easy to adjust. The sensitivity adjustment range is 0.5mV/ to 2.2mV/V, and the offset adjustment range is ±1.8V. The required power supply is ±12 to 15V, 20mA. The external dimensions are 50×30×13.
Load cell amplifier
The A-632L is a load cell amplifier that incorporates a power supply for driving load cells and can be directly connected to a 350Ω load cell. It uses a low-noise measurement amplifier IC (Analog Devices AD8221AR). It operates with a power supply of ±12V to 15V, requiring a current of 20mA. It is equipped with trimmers for sensitivity adjustment and offset adjustment, making it easy to calibrate. Rated output: ±10V, sensitivity adjustment range: 0.5 to 2.2mV, offset adjustment range: ±1.8V. The response frequency is kept low, resulting in minimal residual output noise.