Battery Power Monitor / Part Number M405K-8701K
For measuring the cell voltage of UPS batteries!
Reduce human costs of discharge testing with comparator functionality.
- Company:シロ産業
- Price:10,000 yen-100,000 yen
1~15 item / All 29 items
For measuring the cell voltage of UPS batteries!
Reduce human costs of discharge testing with comparator functionality.
It was developed to fulfill three purposes: prevention of hypoxia accidents, management of oxygen concentration, and various experiments.
● The real-time oxygen concentration can be monitored on a large LCD. ● Compact and easy to hold design. There is a soft case available as an option. ● Alarm concentration settings can be configured in two stages, with options for upper and lower limits. ● The alarm features an easily identifiable electronic buzzer sound. ● Two red LEDs indicate the alarm. ● You can choose between alarm hold or automatic reset. ● Using external alarm output, control of rotating lights and solenoid valves is possible. ● An analog output of 0-1V can be used to extract oxygen concentration externally.
Compact, lightweight, loud alarm sound. Long usage time.
● Compactly store the sensor cable in the winding section. Display the cable length every 1 meter.
You can confirm a cleanliness level equivalent to ISO Class 7 (Class 10,000), which is almost a sterile space.
● Using a light scattering pulse measurement system that utilizes upward airflow generated by heater heat, it can measure particles of 0.5μm and larger, monitoring cleanliness levels from ISO Class 7 to general outdoor air (ISO Class 9). ● Cleanliness levels from Class 7 to 9 are displayed in five color-coded stages (blue, yellow, yellow, red, red), allowing for easy differentiation of the current cleanliness level. ● The transistor output contacts for external output can transmit the current status to external devices. ● It is compact and easy to carry. ● The power supply is DC 24V, allowing for battery operation as well.
Salivary α-amylase (salivary amylase) can be easily measured in saliva.
Dry Clinical Science Analysis Device It allows for the non-invasive and easy measurement of α-amylase (salivary amylase) contained in saliva. (Approximately 60 seconds)
Ideal for monitoring component concentrations of low-concentration VOC gases!!
● Gas analysis using gas chromatography method Gas separation is performed using a column, allowing for the identification of gas components from the peaks obtained. ● Portable type that does not require a gas cylinder for carrier gas, enabling on-site measurement There is no need to prepare a gas cylinder as the surrounding atmosphere is purified to serve as the carrier gas. Therefore, measurements can be taken on-site, and results can be confirmed immediately. ● Realization of low concentration VOC detection through semiconductor gas sensors and concentration A highly sensitive semiconductor gas sensor is used for gas detection, and by performing a concentration operation, it is possible to detect extremely low concentrations of VOCs in the order of 10μg/m3. (Standard measurement time: 30 minutes) ● Capability to acquire chromatographic data By using the included PC application, chromatograms can be obtained, and chromatographic data can be saved in EXCEL format.
Digital temperature and humidity display monitor
●Temperature and humidity display device using LED with a character height of 57mm ●Alarm output function (optional) that can connect a buzzer, rotating light, etc.
Domestic first: Hydrogen sulfide (H2S) alarm setting value compatible with 1ppm.
・Intrinsic safety explosion-proof structure ・Can be used as explosion-proof equipment even in hydrogen and acetylene atmospheres
CO2 (NDIR method, expressed in ppm) Temperature, humidity MAX/MIN hold function Atmospheric calibration function Low battery indicator
●CO2 (NDIR method, expressed in ppm) ●Temperature, humidity ●MAX/MIN hold function ●With atmospheric calibration function ●Low battery indication ●With alarm function
Non-contact high-speed temperature detection monitor (for screening) / Model number M2846T-1039H
The M2846T-1039H combines high-precision temperature measurement with a camera, using AI to detect multiple individuals at a distance of up to 3 meters (recommended distance is 1 to 2.5 meters) in a non-contact and rapid manner. ■ Overview The M2846T-1039H combines high-precision temperature measurement with a camera, using AI to detect multiple individuals at a distance of up to 3 meters (recommended distance is 1 to 2.5 meters) in a non-contact and rapid manner. It can be used in public areas such as hospitals, schools, and terminals, as well as in warehouses and buildings where fire prevention is necessary. By utilizing the alarm function, a warning sound can alert you even if you are not present at the detection location. During the coronavirus infection period, entry and exit points in public areas involve close checks, manual temperature measurements, paper-based entry management, and manual information dissemination via smartphones. This management takes time and increases the risk of infection among staff due to the need for additional personnel. Furthermore, this method makes it difficult to track infections. The M2846T-1039H, when connected to a network, can help address these issues.
Equipped with a new type R sensor for high functionality and durability, featuring one of the longest continuous usage times in the world, and a diverse lineup of sensors.
■Evolution to High Functionality and Durability ●Achieves a long continuous usage time of 9000 hours Realizes one of the longest continuous usage times in the class of compact portable gas monitors, approximately 9000 hours (*). ●Passes 7m drop durability test Even if dropped during high-altitude work, the risk of malfunction is low, allowing for safe use. ●Equipped with a new high-functionality and high-durability R sensor - The sensor has been renewed. It excels in durability and performance, achieving a 3-year sensor warranty. - Usable in a wide temperature range (-40 to +60°C). - Offers a carbon monoxide sensor that is minimally affected by hydrogen interference, suitable for environments coexisting with hydrogen, such as the steel market. - Features Japan's first dual sensor for carbon monoxide and oxygen, enabling two-component detection in a compact portable format (carbon monoxide and oxygen concentrations can be displayed simultaneously). ■Rich Features and Reliable Design - Protection rating: Equivalent to IP66/67, providing a dustproof and waterproof structure for outdoor work. - Designed with intrinsic safety explosion-proof structure (domestic explosion-proof/ATEX/IECEx), making it usable in hazardous locations. ■Choice of Power Supply Specifications: Rechargeable Battery / Dry Cell Offers two power supply options: a dry cell specification that can be used immediately and a rechargeable battery specification that can be reused (please specify when ordering).
This device is an ideal measuring instrument for agricultural, horticultural, and hydroponic applications that require continuous monitoring of pH and EC values for proper plant growth.
This device displays the pH and EC values of the solution on their respective LCD screens, making it easy to read and monitor. The interchangeable pH electrode MF2PH-1286 is of the gel type, and the connection part is treated for waterproofing. The pH electrode features a unique design that prevents clogging of the liquid junction due to high concentrations of solutions such as phosphates and nitrates. It is equipped with a ground rod to ensure more accurate pH measurements and extend the life of the electrode. Additionally, this device is compact and easy to install and handle. It is an ideal measuring instrument for any application that requires continuous monitoring.
Easy-to-understand notification of ventilation timing The necessity of ventilation In poorly ventilated enclosed spaces, the risk of infection clusters increases.
Easy-to-understand notification of ventilation timing The necessity of ventilation It is said that the risk of infection clusters increases in poorly ventilated enclosed spaces. Measuring CO2 (carbon dioxide) concentration is an effective method to reveal insufficient ventilation in spaces used by many people.
Large CO2 Temperature and Humidity Display Monitor (with Alarm Function) / Model Number M1849HM-4220K
Excellent visibility with large display Notifies ventilation timing with light and buzzer This product meets the conditions as a compliant item with the "Guidelines for the Selection of Carbon Dioxide Concentration Measuring Instruments" issued by the Ministry of Economy, Trade and Industry.
You can understand air pollution through numerical values.
1. The operation buttons have been improved to be more visible and easier to operate than conventional models. 2. Sensitivity has been significantly enhanced due to the high-sensitivity, light-scattering aggregation structure. 3. Equipped with a shoulder belt for easy carrying and simple operation for measurement. 4. Speed measurement that provides results in as little as 30 seconds. 5. Developed as a device for measurement verification, ensuring compatibility with configured devices. 6. Supports two power sources (AC adapter / AA batteries). 7. The measurement unit is equivalent to mg/m³, making it ideal for checking airborne dust levels.