We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for Neutralization Device.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

Neutralization Device Product List and Ranking from 7 Manufacturers, Suppliers and Companies

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

Neutralization Device Manufacturer, Suppliers and Company Rankings

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. タクミナ Osaka//Industrial Machinery
  2. エイチツー Aichi//Machine elements and parts
  3. シーズ Osaka//Industrial Machinery
  4. 4 レゾナック・ガスプロダクツ Kanagawa//Resin/Plastic
  5. 5 トーケミ Osaka//Industrial Machinery

Neutralization Device Product ranking

Last Updated: Aggregation Period:Sep 24, 2025~Oct 21, 2025
This ranking is based on the number of page views on our site.

  1. Boiler Drainage Dedicated pH Neutralization Device 'No Cooling Water Needed for High-Temperature Drainage at 80°C! BK' タクミナ
  2. Automatic pH Neutralization Device 'This One Device for Water Supply and Distribution pH Neutralization! NPK' タクミナ
  3. Alkaline wastewater neutralization device レゾナック・ガスプロダクツ
  4. pH Automatic Neutralization Device Comprehensive Catalog トーケミ
  5. 4 Seas [24-hour continuous unmanned operation possible!] Automatic pH neutralization device シーズ

Neutralization Device Product List

31~38 item / All 38 items

Displayed results

[Pump Delivery Case] Automatic Neutralization Treatment of Acid Washing Wastewater pH

With the expansion of pickling scale, we are considering efficiency improvements! The ability to handle design and construction as a package is highly valued.

We received an inquiry from Company F at the steelworks in Saga Prefecture, stating, "The scale of acid washing has increased, and we would like to automatically neutralize the wash water in the subsequent process." Currently, after acid washing, they are washing with water near the drainage ditch, which is very inefficient. Therefore, they requested to create a pit for washing and to place a neutralization device within that pit. To perform the water washing after acid washing in the pit and pump it directly to the neutralization device, we proposed the size of the collection pit and the pit itself. Additionally, they adopted a corrosion-resistant submersible pump (automatically controlled). [Case Details] ■ Delivery: Saga Prefecture Steelworks ■ Application: Automatic pH neutralization treatment of acid wash wastewater ■ Model: Acid 1-point control 400L/day *For more details, please refer to the PDF document or feel free to contact us.

  • 2022-01-11_11h52_26.png
  • Other pumps

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Case Study】Neutralization Treatment at a Concrete Plant

Collected the supernatant from the sedimentation tank and neutralized it! An example of our support in preparing documents for submission to the government office.

We received a request from a concrete factory in the Chubu region stating, "We would like to neutralize the wastewater generated from washing concrete trucks." Upon further inquiry, we learned that while there is an existing sedimentation tank, there is no neutralization equipment. They were urgently considering this matter due to a notice from the authorities. Therefore, we proposed a flow where the supernatant from the existing sedimentation tank would be neutralized and then discharged. Since the sedimentation tank has a strong alkaline condition, we suggested using a corrosion-resistant submersible pump of the LC type and installed electrodes for liquid level control to ensure only the supernatant is drawn. This matter involved multiple documents due to the authorities' notice, but our company supported the submission of these documents, allowing us to clear the issues without any problems. [Case Overview] ■ Client: Chubu Ready-Mixed Concrete Factory ■ Supplied Product: Automatic pH Neutralization Device ■ Application: pH neutralization treatment of concrete wastewater (including rainwater) *For more details, please refer to the PDF materials or feel free to contact us.

  • image_107.png
  • image_108.png
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Case Study】Neutralization Treatment of CIP Cleaning Wastewater from a Brewery

Ensuring durability even with 80℃ CIP wastewater! Introducing a case study of an automatic pH neutralization system.

We would like to introduce a case where an "automatic pH neutralization device" was delivered to a small-scale brewery in Tokyo. The new factory has introduced a CIP cleaning system and was considering the neutralization of wastewater from the CIP cleaning system. By being involved in the design phase of the factory regarding treatment capacity, raw water pH, temperature, and installation space, we were able to ensure a safe order placement. 【Case Details】 ■ Delivery: Small-scale brewery in Tokyo ■ Purpose: Neutralization treatment of CIP cleaning wastewater * For more details, please refer to the PDF document or feel free to contact us.

  • 2.PNG
  • 3.PNG
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

【Case Study】Neutralization Treatment of Acidic Wastewater from a Dye Factory

Neutralization treatment without using a mixer through circulation operation! A case of manufacturing a neutralization device tailored to the user.

We received an inquiry from a paint factory in Kumamoto Prefecture asking if a custom-made neutralization device could be produced. We would like to introduce a case where we delivered an "automatic pH neutralization device." The order was placed due to the evaluation of our ability to meet all requirements, such as not using a stirrer for the mixing of the neutralization device and operating according to the level sensor of the neutralization tank. Since a stirrer could not be used, we created a water flow using a chemical magnetic pump, enabling the mixing of acidic wastewater and caustic soda. 【Case Overview】 ■ Challenges - No stirrer used for mixing in the neutralization device - Operation according to the level sensor of the neutralization tank ■ Proposal: Custom-made neutralization device tailored to the user ■ Delivery: Paint factory in Kumamoto Prefecture ■ Application: Neutralization treatment of acidic wastewater *For more details, please refer to the PDF document or feel free to contact us.

  • 2.PNG
  • 3.PNG
  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

[Case Study] Neutralization Treatment of Rainwater Containing Concrete

We want to ensure that rainwater outside the standard values is neutralized and not discharged externally!

We received an inquiry from a concrete manufacturing company stating, "We would like to neutralize rainwater on our premises to eliminate the possibility of rainwater draining away being alkaline, as it absorbs concrete dust." Since the neutralization of rainwater, which falls irregularly, raises questions about how to collect it and what size of neutralization equipment is needed, there were challenges regarding the size of the collection pit and flow. We proposed a recording device (receipt type), pH monitoring in the discharge tank, and a flow design to prevent the discharge of rainwater that exceeds the standard values using a return pump. 【Case Details】 ■ Client: K Corporation, Concrete Manufacturing and Secondary Product Manufacturing ■ Purpose: Neutralization treatment of rainwater on the premises *For more details, please download the PDF or feel free to contact us.

  • 1.png
  • 2.png
  • Other water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Seas [24-hour continuous unmanned operation possible!] Automatic pH neutralization device

A 24-hour unmanned pH neutralization system that contributes to labor cost reduction and efficiency! It can handle both acidic and alkaline wastewater, allowing for thorough cost reduction.

【1 Chemical Injection Method PHU Series】 This is a continuous automatic neutralization device suitable for various factory wastewater, ready-mixed concrete plants, and civil engineering sites. It is compactly designed, making it easy to install in various locations, and can operate continuously and unattended for 24 hours. Additionally, by changing the materials, it can handle both acidic and alkaline wastewater. This new unit has been thoroughly designed to reduce costs. ■ Injects chemicals according to the treated water, allowing for efficient operation and reduced running costs. ■ Its compact design makes it easy to install in various locations. ■ Capable of 24-hour continuous unattended operation. ■ Can handle both acidic and alkaline wastewater by changing materials. (Materials for acidic wastewater neutralization tank and recording tank: FRP/L) 【2. Carbon Dioxide Injection Method PHG Series】 Wastewater treatment device using carbon dioxide injection. ■ Compact design makes it effective on construction sites. ■ Neutralization reaction time is quick, preventing abnormal pH changes due to excessive injection. *For more details, please refer to the PDF document or feel free to contact us.

  • pH中和処理装置_phu.jpg
  • phg_02.jpg
  • PC100025-01.jpg
  • phg-p.jpg
  • phu10.jpg
  • Filtration Equipment
  • Other process controls
  • Water treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Dialysis drainage treatment unit - suitable for small-scale and space-saving installation!

Recommended industrial wastewater treatment unit for artificial dialysis clinics opened on a single floor of terminal buildings or urban buildings!

The "FJP-B" is an industrial wastewater treatment unit designed for ground installation (indoor use only). With an overwhelmingly compact installation area, it can be accommodated in tenant buildings. The injection of chemicals is controlled by pH proportional control, achieving a reduction in running costs. It is equipped with guard plates and liquid containment barriers for added safety in case of emergencies. It does not support hot water citric acid wastewater. 【Features】 ■ Suitable for building clinics ■ Safe design for indoor installation ■ Overwhelmingly compact installation area ■ Chemical injection is controlled by pH proportional control, achieving a reduction in running costs ■ Equipped with guard plates and liquid containment barriers for added safety in case of emergencies *For more details, please refer to the PDF materials or feel free to contact us.

  • Wastewater/wastewater treatment equipment

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Are you having trouble with the "pH neutralization treatment method for wastewater"? [Basic Information]

A professional in wastewater treatment and water quality analysis will explain the differences between the "carbon dioxide method" and the "chemical addition method" for pH neutralization! This is a must-see for those struggling with pH neutralization methods.

Factory wastewater and boiler blowdown water often have pH values that are either acidic or alkaline, making it impossible to discharge them as they are. Adjusting such wastewater to a neutral range (around pH 7) is referred to as "pH neutralization treatment." In your factories, you are likely conducting pH neutralization treatment for wastewater such as waste acids and waste alkalis, as well as for coagulation reactions. Generally, there are two common methods of pH neutralization treatment: ◯ Carbon dioxide method ◯ Chemical addition method This document introduces the various types of pH neutralization treatments and explains how pH neutralization is carried out. *For more details, please download the PDF document or feel free to contact us.*

  • Wastewater/wastewater treatment equipment