Displayed results

Triple tilt sensor (laser autocollimator)

[Custom Product (Concept Model)] Simultaneous tilt measurement at three locations, parallel installation possible.

Background of Development Is it possible to create a measuring device that can measure objects arranged in narrow intervals all at once? This was the request from our customers that led to our development. There is a method that involves branching a single light source to measure multiple locations using one receiving unit. However, our company has developed a product equipped with three light sources and three receiving units. This allows us to create a product that does not experience the phenomenon of overlapping spots at the receiving unit, which can cause measurement errors. Features - Simultaneous measurement at three locations - Three sensors operate independently, eliminating measurement errors and detection errors - Integrated sensor and processor

  • Optical Measuring Instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Small tilt sensor (laser autocollimator)

[Made-to-order product] Blue, green, red, infrared wavelength selectable

Background of Development Is there an autocollimator equipped with blue or green wavelengths? This request from our customers led to the development of our product. We have developed a product that can flexibly accommodate wavelengths and beam diameters that were difficult to handle with conventional products. Features - Selectable wavelengths from blue to infrared - Optimization of beam diameter is possible (φ0.5 to φ8mm) - Optimization of light reception sensitivity is possible to accurately measure low-reflection and high-reflectivity measurement targets.

  • Optical Measuring Instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Glass pass tilt sensor (laser autocollimator)

【Custom Product (Concept Model)】No complicated construction required, measurement can be taken from outside the vacuum chamber.

Background of Development Measuring in constant temperature baths and vacuum chambers requires a lot of modifications and construction work, which takes a significant amount of time for setup. Is there a measuring device that can solve such problems? This product was developed in response to customer requests. By measuring from outside the constant temperature bath or vacuum chamber through glass, there is no need to manage the environmental performance of the measuring device, allowing for the development of an easy-to-use product. Features - Measurement from outside the constant temperature bath and vacuum device without any modifications to the equipment, and it is a non-contact measurement. - Compact and lightweight for easy setup. - Non-contact measurement ensures safety and security without damaging the measured object.

  • Optical Measuring Instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

C-mount tilt sensor (laser autocollimator)

[Custom Product (Concept Model)] Autocollimator + C-Mount for Easy Measurement

Background of Development We developed this product in response to customer requests for easier optical axis adjustment and inspection of lens barrels and C-mount equipped products used in machine vision cameras. We created a product that integrates the C-mount surface, allowing for stable measurement results by incorporating a reference surface, which enhances reliability and speeds up the workflow. Features - Industry's first integrated tilt sensor with C-mount - Measurement laser is emitted vertically from the center position to the flange surface of the C-mount - Compact and high-precision measurement

  • Optical Measuring Instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

High-resolution tilt sensor (laser autocollimator)

[Custom Product] Tilt sensor with high resolution in another dimension (0.1 arcsec / 0.5 μrad)

Background of Development Is there a measuring device with higher resolution than ultra-small tilt sensors? This product was developed in response to such customer requests. The birth of an ultra-high-resolution sensor that surpasses our company's highest resolution of 1 arcsecond marks the beginning of a new world of measurement. Features - World-class high resolution (0.1 arcsecond / 0.5 μrad) - Processor and sensor are separated to accommodate various applications - Easy measurement with included software (for Windows)

  • Optical Measuring Instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Parallelism tilt sensor (laser autocollimator)

[Custom Product] Easy Measurement of Parallelism on Opposing Surfaces

Background of Development Is there a simple method to measure the parallelism of opposing surfaces? This product was developed in response to such customer requests. It is designed to be slim for installation in the gaps to be measured. This product solves the cumbersome process of measuring parallelism, replacing previous methods like pressure-sensitive paper that could not manage numerical values.

  • Optical Measuring Instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Infrared high-resolution tilt sensor with guide laser

[Custom Product] Achieves high resolution with infrared laser installation.

Background of Development We developed this product in response to customer requests for an autocollimator with higher resolution than ultra-compact tilt sensors and equipped with an infrared laser. By narrowing the measurement range, we achieved high resolution. Since infrared light is invisible, we anticipated that initial alignment would be challenging, so we incorporated a visible red guide laser for development. Features 1. World-class high resolution (0.1 arcmin / 0.5 μrad) 2. Equipped with an infrared wavelength (1064 nm) laser 3. Equipped with a visible light (red 650 nm) guide laser

  • Optical Measuring Instruments

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration