We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column×アジレント・テクノロジー株式会社 - List of Manufacturers, Suppliers, Companies and Products

column Product List

136~150 item / All 225 items

Displayed results

Low bleed GC/MS column 'VF-1301ms'

Thin film type of "VF-624ms"! A GC capillary column that significantly increases the S/N ratio and improves quantitative accuracy!

The "VF-1301ms" is a GC capillary column that achieves ultra-low bleed with a stationary phase consisting of 6% cyanopropylphenyl and 94% dimethylpolysiloxane. It uses the same stationary phase as the "VF-624ms." With a thin film thickness, it is suitable for the analysis of volatile organic solvents and pesticides. Additionally, ghost peaks have disappeared, and the baseline is stable. 【Features】 ■ Uses the same stationary phase as the "VF-624ms" ■ Significantly increases the S/N ratio and improves quantitative accuracy ■ Ghost peaks have disappeared, and the baseline is stable ■ Suitable for the analysis of volatile organic compounds and pesticides *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "VF-1701ms"

Achieving ultra-low bleed with FactorFour technology! A column suitable for the analysis of semi-volatile organic compounds!

The "VF-1701ms" is a GC capillary column that uses 14% cyanopropylphenyl and 86% dimethylpolysiloxane as the liquid phase, achieving ultra-low bleed. It is suitable for the analysis of semi-volatile organic solvents and pesticides. The FactorFour technology enables ultra-low bleed, improving the S/N ratio. Additionally, the column bleed is guaranteed to be below 2 pA at 280°C. 【Features】 ■Improves the S/N ratio ■Column bleed is guaranteed to be below 2 pA at 280°C (for 0.25mm × 60m, 0.25μm) ■Good reproducibility for challenging compounds like p,p'-DDT ■High inertness and excellent accuracy ■Ghost peaks disappear and the baseline remains stable *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 5 CB UltiMetal"

Introducing a column that helps reduce costs and has a wide usable temperature range!

"CP-Sil 5 CB UltiMetal" is a metal column that contains 100% dimethylpolysiloxane in the liquid phase. It is chemically bonded, highly inert, resistant to large injections, and can be used with good reproducibility. Separation is based on the boiling points of compounds and can be applied over a wide temperature range. [Features] - Contains 100% dimethylpolysiloxane in the liquid phase - Chemically bonded, highly inert, resistant to large injections, and can be used with good reproducibility - Helps reduce costs - Applicable to various analyses - Available in two types: fused silica and metal columns *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "Ultra 1"

Since it undergoes testing based on QC specifications, it is possible to obtain highly reliable qualitative/quantitative results!

"Ultra 1" is a precision-designed column that is chemically bonded, cross-linked, and can be cleaned with solvents. It is tested based on very strict QC standards, ensuring consistently high accuracy and integrity of analytical results. Additionally, the operating temperature range is -60 to 325℃/350℃, suitable for the Sadtler retention index library. 【Features】 ■ 100% Dimethylpolysiloxane ■ Non-polar ■ Equivalent to "HP-1," but with more stringent specifications for retention index and capacity factor ■ Chemically bonded, cross-linked type ■ Can be cleaned with solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-5"

Low breed! We introduce a non-polar column with a wide range of applications at high upper temperature limits!

The "DB-5" is a non-polar column made of (5% phenyl) methyl siloxane. It features a chemical bond and crosslinking type, and is capable of solvent washing. It corresponds to USP Phase G27, and we offer a wide variety of column sizes. Please feel free to contact us when you need assistance. 【Features】 ■ (5%-phenyl)-methyl polysiloxane ■ Non-polar ■ Excellent general-purpose column ■ Wide range of applications ■ Low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "HP-5"

Chemical bonding and cross-linking type, with a wide range of applications! We introduce an excellent general-purpose column!

The "HP-5" is a non-polar column made of (5%-phenyl)-methylpolysiloxane. It corresponds to USP Phase G27 and can be solvent cleaned at high upper temperature. We continue to pursue further improvements in analytical performance standards such as separation efficiency, reproducibility of retention times, and peak height ratios. Please feel free to contact us when you need assistance. 【Features】 ■ (5%-phenyl)-methylpolysiloxane ■ Non-polar ■ Excellent general-purpose column ■ Wide range of applications ■ High upper temperature *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "CP-Sil 8 CB"

It shows excellent selectivity for aromatic compounds and is a suitable column for condition testing!

The 'CP-Sil 8 CB', which uses 5% phenyl and 95% dimethyl polysiloxane as the liquid phase, is a column with slightly higher polarity than the 'CP-Sil 5 CB'. It demonstrates excellent selectivity for aromatic compounds and is suitable for condition testing. Additionally, it shows good inter-column reproducibility, high separation efficiency, and selectivity. 【Features】 ■ Uses 5% phenyl and 95% dimethyl polysiloxane as the liquid phase ■ High-efficiency and high-precision GC column ■ Offers various column sizes ■ Improves productivity with excellent reproducibility and selectivity *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

C18 column "CP-Sil 13 CB"

Solvent washing is possible in chemically bonded liquid phases! Suitable for detection by ECD with a non-cyano medium-polarity column.

The "CP-Sil 13 CB" is a medium-polarity column developed for appropriate analysis using methods that detect ECD, such as halocarbons. The liquid phase consists of 14% phenyl and 86% dimethylpolysiloxane, and since it does not contain cyano propyl, there is no observed baseline rise with ECD detection. It allows for solvent washing with a chemically bonded liquid phase, making it ideal as a confirmation column for analysis. 【Features】 ■ Solvent washing is possible with a chemically bonded liquid phase ■ Ideal as a confirmation column for analysis ■ Suitable for ECD detection with a non-cyano medium-polarity column *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-35"

Pursuing further improvement in analysis performance standards such as separation efficiency and peak height ratio!

We would like to introduce the GC column "DB-35" that we handle. It has a slightly higher polarity than medium polarity (HP-35) and low bleed. It is inert to active solutes and suitable for confirmation analysis. It is a chemically bonded and cross-linked type, allowing for solvent washing. 【Features】 ■ (35%-phenyl) methyl polysiloxane ■ Slightly higher polarity than medium polarity (HP-35) ■ Low bleed ■ Inert to active solutes ■ Suitable for confirmation analysis *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC Column "HP-35"

Methyl siloxane column with substituted phenyl groups! Suitable for EPA Method 8081.

We would like to introduce the GC column "HP-35" that we handle. This is a methyl siloxane column with phenyl groups substituted. This column is suitable for EPA Method 8081 and is equivalent to USP G-42. Additionally, due to its medium polarity, it is suitable for the analysis of pesticides, herbicides, pharmaceuticals, and amines. 【Features】 ■ (35%-phenyl) methyl polysiloxane ■ Slightly lower polarity than medium polarity (DB-35) ■ Inactive towards active solutes ■ Suitable for confirmatory analysis ■ Chemically bonded and cross-linked type *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-200"

Suitable for separating difficult-to-separate positional isomers! Introducing a medium-polarity column of methyl polysiloxane.

We would like to introduce our product, the "DB-200." It is a medium-polarity column made of (35% trifluoropropyl) methylpolysiloxane. It has a higher polarity than the medium-polarity "DB-1701" and "DB-17," and exhibits unique interactions with compounds containing nitro groups, halogen groups, and carbonyl groups. 【Features】 ■ (35% trifluoropropyl) methylpolysiloxane ■ Temperature limit 300/320℃ ■ Higher polarity than medium-polarity "DB-1701" and "DB-17" ■ Suitable for difficult-to-separate positional isomers ■ Exhibits unique interactions with compounds containing nitro groups, halogen groups, and carbonyl groups *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-210"

Suitable for U.S. EPA Methods 8140 and 609! Chemical bonding/crosslinking type, solvent cleaning possible.

We would like to introduce our GC column "DB-210." It is equivalent to (50% trifluoropropyl) methyl polysiloxane and has high polarity. It is suitable for U.S. EPA Methods 8140 and 609 and is a chemically bonded and cross-linked type. It allows for solvent cleaning and serves as a replacement for HP-210. 【Features】 ■ (50% trifluoropropyl) methyl polysiloxane ■ High polarity ■ Suitable for U.S. EPA Methods 8140 and 609 ■ Chemically bonded and cross-linked type ■ Solvent cleaning possible ■ Replacement for HP-210 ■ Equivalent to USP Phase G6 *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-1301"

Pursuing further improvement of performance standards! Alternatives to HP-1301/HP-1701.

We would like to introduce our GC column "DB-1301." It is a (6% cyanopropylphenyl) methylpolysiloxane, equivalent to USP Phase G43. It has low to medium polarity and is of the chemical bond/crosslink type. It serves as a substitute for HP-1301/HP-1701. 【Features】 ■ (6% cyanopropylphenyl) methylpolysiloxane ■ Equivalent to USP Phase G43 ■ Low to medium polarity ■ Chemical bond/crosslink type ■ Substitute for HP-1301/HP-1701 ■ Solvent-cleanable *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "SE-30/SE-54"

Highly reliable qualitative/quantitative results can be obtained! Operating temperature range is 0 to 325/350℃.

The "SE-30" is a 100% dimethyl polysiloxane column, while the "SE-54" is a (5%-phenyl) (1%-vinyl)-methyl polysiloxane column. Both columns are precisely designed to ensure a temperature operating range of 0 to 325/350°C, providing high accuracy, efficiency, and reproducibility of results. These columns can be used in established methods that require columns without cross-linked or chemically bonded polymer phases, as they are neither chemically bonded nor cross-linked. 【Features】 ■ Operating temperature range of 0 to 325/350°C ■ Precisely designed to ensure high accuracy, efficiency, and reproducibility of results ■ Neither chemically bonded nor cross-linked ■ Can be used in established methods that require columns without cross-linked or chemically bonded polymer phases *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column 'DB-WAXetr'

Excellent reproducibility between columns! Introducing solvent-washable chemical bond and crosslink type columns.

The "DB-WAXetr" is a column with a wide temperature range and high polarity. It is a chemically bonded and cross-linked type, and can be cleaned with solvents. It corresponds to USP Phase G16. Our commitment to the reliability and reproducibility of our products supports the improvement of quality levels demanded by chromatography professionals. 【Features】 ■ Polyethylene glycol (PEG) ■ Wide temperature range (etr: Extend Temperature Range) ■ High polarity ■ Excellent reproducibility between columns ■ Chemically bonded and cross-linked type ■ Can be cleaned with solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration