We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column×アジレント・テクノロジー株式会社 - List of Manufacturers, Suppliers, Companies and Products

column Product List

1~15 item / All 225 items

Displayed results

GC and GC/MS columns

Minimal downtime! Achieves excellent performance with high reproducibility even for samples that are difficult to analyze!

Agilent has been leading innovations in gas chromatography for over 40 years, introducing groundbreaking products. We also offer a comprehensive range of columns and consumables for GC and GC/MS in the industry. The Agilent J&W Ultra Inert GC columns are tested using rigorous industry-standard probes, achieving low detection limits and providing high-precision data for challenging target compounds. Our GC and GC/MS cover the essential elements required for trace analysis, dramatically improving the separation capability of MS, spectral integrity, and detection limits. 【Column Analysis Equipment Lineup (Partial)】 ■Agilent 7890B GC ■Agilent 7820A GC ■Agilent 6850 Series II GC ■Agilent 7697A Headspace Sampler ■Agilent 490 Micro GC and 490-PRO *For more details, please refer to the PDF materials or feel free to contact us.

  • Gas recovery/treatment equipment
  • Separation device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

The inner diameter is 1 inch, 2 inches, 3 inches! LC column

Supports dynamic axial compression (DAC) and static axial compression (SAC)! Enables time reduction and operational cost savings!

The "Load & Lock Column" achieves the highest levels of purity and yield when used in conjunction with the InfinityLab LC purification solution. It is available in inner diameters of 1 inch, 2 inches, and 3 inches, and achieves high performance and high throughput with simple filling operations. Sample loading is 20% higher than DAC-type columns, allowing for reduced time and operational costs. 【Features】 ■ Unique dispersion plate and fluid structure improve sample load capacity by up to 20% ■ Dynamic axial compression (DAC) and static axial compression (SAC) can be applied to the same column ■ Various inner diameter filling operations can be performed with a single Agilent Packing Station ■ The column and filling station are integrated into a wheeled base ■ Filling and extraction of packing material can be done with simple tasks in just a few minutes *For more details, please refer to the related link page or feel free to contact us.

  • Analytical Equipment and Devices
  • Separation device

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent J&W Ultra Inert Capillary GC Column

Achieve excellent performance and highly reliable data! Supports a column with an inner diameter of 0.18mm.

The "Agilent J&W Ultra Inert Capillary GC Column" is a new product that achieves consistent inertness and excellent peak shape. Individually tested with Ultra Inert test mixtures. It also supports 0.18mm inner diameter columns for high-speed, high-resolution analysis. We offer a lineup of 5ms, 1ms, 35ms, 624, and WAX. 【Features】 ■ Highest level of column inertness ■ Low column bleed ■ Excellent peak shape for challenging active substances ■ Superior signal-to-noise ratio ■ Same selectivity as existing J&W 5ms, 1ms, 35ms, 624, and WAX *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent J&W Ultra Inert GC/MS Column

Introducing a column that reduces noise and suppresses peak tailing of active compounds!

The "Agilent J&W Ultra Inert GC/MS Column" minimizes peak tailing and baseline rise of active compounds, providing excellent analytical results. Current laboratories are under increasing pressure to comply with rapidly growing regulations while delivering accurate results quickly. By using this product, you can improve the detection limits for challenging target compounds. 【Features】 ■ Detection of active compounds at trace concentrations ■ Minimal peak tailing for active analytes ■ Longer maintenance-free time, which is crucial for the equipment ■ Minimal loss and degradation of compounds for more accurate quantification *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent J&W DB-WAX Ultra Inert GC Column

No need for analysis in individual FFAP columns! By standardizing, it can accommodate a wide range of applications.

The "Agilent J&W DB-WAX Ultra Inert GC Column" features extremely high inertness, providing more reliable peak shapes and excellent durability compared to standard WAX columns. In the analysis of active compounds, adsorption in the flow path significantly impacts the reliability of the analytical results. This product alleviates concerns associated with the analysis of polar compounds. 【Features】 ■ Reduces the need for troubleshooting and reanalysis ■ Saves costs on columns ■ Eliminates the need for pre-qualification of columns ■ Facilitates method conversion ■ Maintains exceptional inertness even after exposure to 250°C for 50 hours *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

DB-WAX Ultra Inert GC Column <High Reliability for Analysis>

It is suitable for chemical analysis in spice applications, quality control labs, and method development labs!

The "Agilent J&W DB-WAX Ultra Inert GC Column" dispels concerns associated with the analysis of polar compounds. It achieves excellent peak shape, reliable column-to-column reproducibility of inertness, and more stable retention times. Moreover, even after repeated temperature cycling up to the column's maximum temperature, excellent inertness is maintained over the long term. 【Features】 ■ Excellent peak shape for acidic compounds ■ Stable inert performance for alcohols and glycols ■ Excellent durability for water-soluble samples ■ Easy upgrade to more reliable qualitative and quantitative methods *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "DB-1ms"

Ideal for GC/MS analysis! Improved S/N ratio enhances sensitivity and reliability of mass spectra.

The "DB-1ms" is a low bleed GC/MS column that can achieve maximum response to active samples commonly used in drug screening and environmental analysis due to its inertness. By using a low bleed stationary phase, background noise caused by the column is reduced, increasing the signal-to-noise ratio and resulting in improved sensitivity. Additionally, low bleed columns enhance the purity of mass spectra, leading to more accurate library identifications. 【Features】 ■ 100% Dimethylpolysiloxane ■ Same selectivity as DB-1 ■ Non-polar ■ Suitable as a general-purpose column with ultra-low bleed *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "VF-1ms"

High precision and high sensitivity non-polar columns! Measuring with good sensitivity across a wide range of application fields.

We would like to introduce the 'VF-1ms' that we handle. It is a non-polar, ultra-low bleed GC column that has undergone advanced deactivation treatment to achieve improved sensitivity in various analyses. Using 100% dimethylpolysiloxane as the stationary phase, it guarantees a bleed value of less than 1 pA at 325°C (for 0.25mm × 30m, 0.25μm). 【Features】 ■ Guarantees ultra-low bleed suitable for trace level analysis ■ Applicable to a wide range of analyses ■ Provides high-precision analytical results with advanced deactivation treatment ■ Maximum operating temperature: 325°C (isothermal), 350°C (temperature ramp) ■ Minimum operating temperature: -60°C *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "DB-5ms"

Improvement of the S/N ratio enhances the sensitivity and reliability of the mass spectrum! Suitable for ultra-low bleed GC/MS.

The "DB-5ms" is a non-polar column that uses Phenyl Arylene polymer. It has ultra-low bleed, making it suitable for use in GC/MS analysis. The improvement in the S/N ratio enhances sensitivity and the reliability of the mass spectrum. We offer a wide variety of "GC and GC/MS columns." Please feel free to consult us when needed. 【Features】 ■ Almost equivalent to (5%-phenyl)-methylpolysiloxane, Phenyl Arylene polymer ■ Non-polar ■ Ultra-low bleed, suitable for GC/MS ■ Excellent inertness towards active compounds ■ Improvement in S/N ratio enhances sensitivity and reliability of the mass spectrum *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "HP-5ms"

Solvent cleaning is possible! Improved S/N ratio enhances sensitivity and reliability of mass spectra.

We would like to introduce the 'HP-5ms' handled by Agilent Technologies, Inc. It achieves excellent inertness against activated compounds containing acidic and basic substances. With its ultra-low bleed characteristics, it is suitable for GC/MS analysis. We offer a wide variety of "GC and GC/MS columns." Please feel free to consult us when needed. 【Features】 ■ (5%-Phenyl)-methylpolysiloxane ■ Selectivity equal to HP-5 ■ Suitable for GC/MS analysis with ultra-low bleed characteristics ■ Solvent-washable ■ Non-polar *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "VF-5ms"

Guaranteed performance for each item with full inspection of the column! Usable even for highly polar compounds.

The "VF-5ms" is a 5% phenyl column that has undergone advanced inert treatment, designed to maximize sensitivity, accuracy, and the operational efficiency of GC with low bleed GC/MS capabilities. Column bleed is guaranteed to be below 1 pA at 325°C (for 0.25mm × 30m, 0.25μm). It has a slightly higher polarity than VF-1ms and offers excellent selectivity for aromatic compounds. Additionally, due to the advanced inert treatment, it can also be used for highly polar compounds such as phenols. 【Features】 ■ Excellent selectivity for aromatic compounds ■ Improved sensitivity with ultra-low bleed ■ Individual performance guaranteed through complete inspection of all columns *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "DB-XLB"

Expand the temperature limit to 340/360℃! It is possible to create a Duraguard column.

Introducing the 'DB-XLB' handled by Agilent Technologies, Inc. It is possible to create a Duraguard column (guard column integrated column). It is suitable for confirmation analysis, pesticide and herbicide analysis, PCB and PAH analysis, and GC/MS. We offer a wide variety of "GC and GC/MS columns." Please feel free to consult us when needed. 【Features】 ■ Low polarity ■ Temperature limit extended to 340/360℃ ■ Unique selectivity ■ Excellent inertness towards active compounds ■ Suitable for confirmation analysis *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Low bleed GC/MS column "VF-Xms"

High-purity arylene compounds provide highly accurate analytical results! Ideal for both simultaneous testing and confirmation testing.

The "VF-Xms" is a stable low bleed GC/MS column that shows low bleed among all FactorFour columns. It offers top-class sensitivity and S/N ratio, demonstrating higher polarity than the VF-5ms. Additionally, compared to non-polar MS grade columns, this product is ideal for applications that require high separation efficiency in a short time, such as simultaneous analysis of pesticides. 【Features】 ■ High-purity arylene compounds for high-precision analytical results ■ Usable up to 340°C under isothermal conditions, accommodating a wide range of analyses ■ Ideal column for both simultaneous testing and confirmation testing *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-UI 8270D Ultra Inert"

Excellent peak shape at low concentration! Individually tested at low temperatures using highly verifiable semi-volatile compounds.

We would like to introduce the GC column "DB-UI 8270D Ultra Inert" that we handle. When used for the analysis of semi-volatile organic compounds targeted by EPA Method 8270D, it provides excellent peak shapes, thereby enhancing the reliability of trace analysis in the environmental field. Thanks to Agilent's advanced manufacturing processes, optimized chemistry, and design advancements, both inertness and column-to-column reproducibility are improved, and there is no reduction in bleed or selectivity of the stationary phase. 【Features】 - Industry-leading Ultra Inert treatment and manufacturing - Highly reliable results through excellent testing protocols - "MS Grade" low bleed stationary phase minimizes interference from the column even at high temperatures *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC Column "DB-BAC1/DB-BAC2 Ultra Inert"

Polar target compounds can also be accurately identified! An excellent solution for precise blood alcohol quantification.

The "DB-BAC1/DB-BAC2 Ultra Inert" is a column from the Agilent J&W Ultra Inert GC column family. It is capable of separating t-butanol and n-propanol from commonly encountered interferences in blood matrices. Using this column set in GC/FID/FID analysis achieves excellent selectivity due to the unique polarity of the columns. 【Features】 ■ An excellent solution for accurate blood alcohol quantification ■ Optimized separation capability and baseline separation for challenging peaks in blood alcohol ■ Provides excellent peak shape for low concentration compounds, enabling accurate integration ■ Can accurately identify polar target compounds that are difficult to analyze at trace concentrations *For more details, please refer to the PDF materials or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration