We have compiled a list of manufacturers, distributors, product information, reference prices, and rankings for column.
ipros is IPROS GMS IPROS One of the largest technical database sites in Japan that collects information on.

column×アジレント・テクノロジー株式会社 - List of Manufacturers, Suppliers, Companies and Products

column Product List

166~180 item / All 225 items

Displayed results

Non-polar column "HP-PAS5"

Chemical bonding and cross-linking type! Specifically designed and processed for the analysis of organic chlorine pesticides.

The "HP-PAS5" is a non-polar column specifically designed and treated for the analysis of organochlorine pesticides. The operating temperature range is -60 to 325/350°C, and it has undergone ECD testing to minimize pesticide decomposition and achieve low ECD bleed. It features chemical bonding and cross-linking, is washable with solvents, and has been tested against strict QC industry standards, providing high reliability in the accuracy and integrity of analytical results. 【Features】 ■ Non-polar ■ Specifically designed and treated for the analysis of organochlorine pesticides ■ ECD testing ensures minimal pesticide decomposition and low ECD bleed ■ Chemical bonding and cross-linking type ■ Washable with solvents *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Rapid-MS"

Outstanding sensitivity following the FactorFour VF-5ms! Compatible with any manufacturer's GC!

"Rapid-MS" is a capillary column that performs GC/MS analysis at speeds approximately 3 to 5 times faster under temperature ramp conditions and about 10 times faster under isothermal conditions. To accommodate a wide range of analyses, it is available with film thicknesses from 0.1 to 1.0 μm, while also improving the S/N ratio by about 3 times. It can be connected to any manufacturer's GC. 【Features】 ■ Maximizes productivity with rapid analysis ■ Excellent sensitivity following the FactorFour VF-5ms ■ Compatible with any manufacturer's GC (used for GC/MS) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "VF-17ms for PAH"

The confirmation column of the EPA method, which maximizes the reliability of analysis results, is suitable!

The "VF-17ms for PAH" is a column that can separate polycyclic aromatic hydrocarbons, which are regulated by the EU and EPA, in less than 30 minutes. With inertization technology, it improves data quality and maximizes the reliability of analytical results, making it suitable as a confirmation column for EPA methods. It is a chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs. 【Features】 ■ Capable of separating polycyclic aromatic hydrocarbons regulated by the EU and EPA in less than 30 minutes ■ Improves data quality through inertization technology ■ Highly suitable as a confirmation column for EPA methods, maximizing the reliability of analytical results ■ A chemical bond/crosslink type that can be cleaned with solvents, helping to reduce column replacement costs ■ Subjected to tests based on very strict QC specifications in the industry regarding column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative/quantitative results *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 88 for Dioxins"

A leak-free integrated retention gap! Extends column life when using splitless injection.

"CP-Sil 88 for Dioxins" is an ultra-high polarity column specifically designed for the separation of dioxins and dibenzofurans. It features an integrated retention gap, which prevents issues caused by solvent condensation and allows for repeated splitless injection without degrading the stationary phase. Additionally, the column's lifespan is extended, and data quality is significantly improved. 【Features】 ■ High-polarity stationary phase with selectivity specialized for the separation of dioxins and dibenzofurans ■ Integrated retention gap with no leaks, extending column lifespan during splitless injection ■ Capable of measuring low concentrations of 2,3,7,8-TCDD ■ Columns with a thin film configuration and a temperature program limit of 270°C are also available *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC column "DB-624"

Chemical bonding and cross-linking type! No cryo-focusing required with U.S. EPA Method 502.2!

The DB-624 is a GC column specifically developed for the analysis of volatile contaminants. It is suitable for U.S. EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, and 8260. Our company continues to pursue further improvements in analytical performance standards such as separation efficiency, retention time reproducibility, and peak height ratios. 【Features】 ■ Specifically developed for the analysis of volatile contaminants ■ No cryo-focus required for U.S. EPA Method 502.2 ■ Suitable for U.S. EPA Methods 501.3, 502.2, 503.1, 524.2, 601, 602, 8010, 8015, 8020, 8240, and 8260 ■ Excellent inertness towards active substances ■ Chemical bonding and cross-linking type *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "DB-VRX"

A wide operating temperature range of -20 to 260℃! Introducing a low-polarity column that can be cleaned with solvents!

The "DB-VRX" is a low-polarity column designed with unique selectivity to achieve appropriate resolution for volatile compounds. It features excellent peak shape and fully complies with U.S. EPA Methods 502.2, 524.2, and 8260. This type of column, which utilizes chemical bonding and cross-linking, does not require cooling below room temperature to separate six "gases." A wide operating temperature range of -20 to 260°C is also one of its characteristics. 【Features】 ■ Unique selectivity designed to achieve appropriate separation capability in the analysis of volatile compounds: U.S. EPA Methods 502.2, 524.2, and 8260 ■ The 0.45mm inner diameter column has a greater theoretical plate count per meter than the 0.53mm inner diameter column, minimizing co-elution in GC methods ■ No cooling below room temperature is required for the separation of six "gases" ■ Fast analysis - Less than 30 minutes (with appropriate sample throughput) - Less than 8 minutes (when using a 0.18mm inner diameter column) *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select Mineral Oil"

Available in fuse silica and UltiMetal! We also offer economical packs of 3 and 6.

The "Select Mineral Oil" column is designed for the high-speed analysis of mineral oils and features a stabilized non-polar bonded phase. It can withstand temperatures up to 375/400°C and enables high-speed analysis based on the DIN H53 and DIN-EN-ISO 9377-2 methods. With excellent temperature stability, it can analyze hydrocarbons from C4 to C40 in less than 10 minutes, significantly reducing bake-out time. 【Features】 ■ Stabilized non-polar bonded phase designed for the high-speed analysis of mineral oils ■ Appropriate selectivity that enhances the reliability of analysis results for total petroleum hydrocarbons (TPH) based on the DIN H53 N-ISO 9377-2 method ■ Capable of analyzing hydrocarbons from C4 to C40 in less than 10 minutes ■ Low bleed ■ Available in fused silica and UltiMetal *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "Select Low Ammonia"

Designed for GC/NCD! Introducing a column that can obtain highly reliable qualitative/quantitative results!

The "Select Low Ammonia" column is designed to enable simple and rapid analysis of ammonia gas in light hydrocarbons using GC/NCD. This column achieves a low detection limit for ammonia at the ppbv level. Please feel free to contact us when needed. 【Features】 ■ Low detection limit for ammonia in light hydrocarbons ■ Designed for GC/NCD ■ Restrictor connected ■ It has undergone testing based on the industry's very stringent QC specifications for column bleed, sensitivity, and efficiency, allowing for highly reliable qualitative and quantitative results. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

GC Column "Select Volatiles"

The peak shape is very good! This is an application column optimized for environmental analysis.

"Select Volatiles" is an application column that resolves the peak shape of 1,4-dioxane and the separation of 1,4-dioxane-d8 and 1,2-dichloropropene. Due to its inner diameter of 0.20 mm, it is effective in reducing analysis time and saving helium gas. Additionally, it excels in reproducibility and durability for purge and trap-GC/MSD and headspace-GC/MSD analyses. 【Features】 ■ The peak shape of 1,4-dioxane is very good. ■ 1,4-dioxane-d8 and 1,2-dichloropropane are baseline separated. ■ The inner diameter of 0.20 mm is effective in reducing analysis time and saving helium gas. ■ Excellent reproducibility and durability in purge and trap-GC/MSD and headspace-GC/MSD analyses. *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-Sil 88"

High selectivity for positional isomers and geometric isomers! Separation columns for compounds with similar boiling points and polarities.

"CP-Sil 88" is a column that uses stabilized high-purity cyano-propyl as the liquid phase. It demonstrates high separation capability even for compounds with similar boiling points and polarities, such as positional isomers and geometric isomers. Please feel free to contact us when you need assistance. 【Features】 ■ High selectivity for positional isomers and geometric isomers ■ High-purity cyano-propyl liquid phase ■ Non-covalent high-polarity column *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "CP-FFAP CB"

By using a chemical bonding type of liquid phase, we prevent the collapse of the liquid phase due to acid!

The "CP-FFAP CB" is a column that guarantees the analysis of free fatty acids. Due to its high maximum operating temperature of 250°C, it can analyze free fatty acids from C2 to C24 in a single measurement without the need for derivatization. By using a chemically bonded liquid phase, it prevents the breakdown of the liquid phase due to acids. Even with continuous injection of large amounts of water or organic solvents, the column does not get damaged. 【Features】 ■ Guarantees the analysis of free fatty acids ■ Analyzes fatty acids from C2 to C24 in one go without the need for derivatization ■ High durability against water and organic solvents ■ Chemically bonded for long lifespan *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Agilent GC columns applicable to the test items of each pharmaceutical article in GC analysis.

Publication of test items such as 'purity test (6) carbon monoxide' and 'quantitative method'!

This is an introduction to the target GC columns in accordance with the 18th revision of the Japanese Pharmacopoeia (Ministry of Health, Labour and Welfare Notification No. 220, June 7, 2021). It includes items such as "nitrous oxide" and "acethexamide" under "Pharmaceutical Articles," as well as "part numbers" and "specified columns." You can view detailed information through the related links. We encourage you to read it. 【Listed Items (Partial)】 ■ Pharmaceutical Articles ■ Test Items ■ Part Numbers ■ Names *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraBOND Q"

Introducing analysis columns for C1 to C9 hydrocarbons and halogenated compounds!

"PoraBOND Q" is a GC capillary column that can be widely used for the analysis of volatile organic solvents and hydrocarbons. This product is capable of withstanding repeated analyses of moisture-containing samples. The polymer used as the adsorbent has high purity, and even when used at 320°C, decomposition of compounds due to the adsorbent is minimal. 【Features】 ■ Provides stable data with a chemically bonded PLOT column ■ Capable of analyzing various hydrocarbons ■ Expanded maximum operating temperature *For more details, please refer to the PDF document or feel free to contact us.

  • Analytical Equipment and Devices

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "PoraPLOT Q-HT"

The reproducibility of retention time is stable! Water elutes with a sharp peak, improving quantitative accuracy.

"PoraPLOT Q-HT" is a column for the analysis of volatile compounds. The maximum operating temperature has been expanded to 290°C. It can be used for applications involving halogenated compounds, hydrocarbons C1 to C6, organic solvents, and more. Please feel free to consult us when you need assistance. 【Features】 ■ Suitable for the analysis of a wide range of volatile compounds from high polarity to non-polar ■ Water elutes with sharp peaks, improving quantification accuracy ■ Stable reproducibility of retention times *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration

Column "HP-PLOT Q"

Durable and recommended "Q" column! Good separation can be achieved in various applications.

"HP-PLOT Q" is a column made of bonded polystyrene-divinylbenzene. It can be used at a temperature limit of -60 to 270/290°C. Good separations are achieved in applications involving hydrocarbons, CO2, methane, air/CO, water, polar solvents, sulfur compounds, and more. It provides high separation in a shorter time compared to traditional packed columns. Please feel free to consult us when you need assistance. 【Features】 ■ Bonded polystyrene-divinylbenzene (DVB) column ■ A PLOT column with intermediate polarity between Porapak-Q and Porapak-N ■ A PLOT column that serves as an alternative to packed columns ■ High separation in a shorter time than traditional packed columns ■ Requires a minimum of 1 hour for conditioning *For more details, please refer to the PDF document or feel free to contact us.

  • Other consumables

Added to bookmarks

Bookmarks list

Bookmark has been removed

Bookmarks list

You can't add any more bookmarks

By registering as a member, you can increase the number of bookmarks you can save and organize them with labels.

Free membership registration